Relay - 600 V 10 Amp Tesys + Options

Relay 600v 10 Amp Tesys + Opti

SQDCAD32G7TQ CAD32G7TQ 3389110847208
70.98 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 86 mm
  • Height: 77 mm
  • Net Weight: 0.58 kg
  • Warranty Length: 18 mth
  • Weight: 0.58 kg
  • Width: 45 mm
TeSys Deca control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 120V 50/60Hz AC control circuit, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 120V 50/60Hz AC control circuit, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CSA || UL || UKCA
    • Ambient Air Temperature For Operation : -40-70 °C at Uc || -5-60 °C at 0.8...1.1 Uc
    • Standards : EN 60947-5 || IEC 60947-5-1 || NF C 63-140 || VDE 0660 || BS 4794 || IEC 60335-1
    • Shock Resistance : 10 gn control relay open || 15 gn control relay closed
    • Vibration Resistance : 2 gn 5-300 Hz control relay open || 4 gn 5-300 Hz control relay closed
    • Ip Degree Of Protection : IP2X conforming to VDE 0106
    • Ambient Air Temperature For Storage : -60-80 °C
    • Protective Treatment : TH IEC 60068
    • Operating Altitude : 9842.52 ft (3000 m) without derating
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1501004
    • Packaging Without Single Use Plastic : Yes
    • Scip Number : b67ac941-f42f-4afd-894a-0b6f9cefde62
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Circularity Profile : ENVEOLI1501004
    • Take-Back : No
    • Sustainable Packaging : Yes
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 16.5
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
    • [Ue] Rated Operational Voltage : <= 690 V AC 25...400 Hz
    • Height : 77 mm
    • Control Circuit Voltage Limits : drop-out: 0.3...0.6 Uc || operational: 0.8...1.1 Uc at 50 Hz || operational: 0.85...1.1 Uc at 60 Hz
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C)
    • Insulation Resistance : > 10 MOhm
    • Irms Rated Making Capacity : 140 A <= 690 V AC IEC 60947-5-1
    • Associated Fuse Rating : 10 A gG <= 690 V IEC 60947-5-1
    • Net Weight : 0.58 kg
    • Inrush Power In Va : 70-70 VA (at 20 °C)
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Contact Operation : mechanically linked IEC 60947-5-1
    • [Ui] Rated Insulation Voltage : 600 VCSA || 600 VUL || 690 V III 3) IEC 60947-5-1
    • Maximum Operating Rate : 3 cyc/s 20 °C
    • Minimum Switching Current : 5 mA
    • Hold-In Power Consumption In Va : 8-8 VA 50 Hz (at 20 °C)
    • Operating Time : 12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening || 4...19 ms coil energisation and NC opening || 6...17 ms coil de-energisation and NC closing
    • Width : 45 mm
    • Depth : 86 mm
    • Tightening Torque : 1.7-1.7 N.m
    • Minimum Switching Voltage : 17 V
  • Specifications
    • Country of Origin : France
    • Width : 45 mm
    • Height : 77 mm
    • Weight : 0.58 kg
    • Control Circuit Type : AC
    • [Uc] Control Circuit Voltage : 120 V AC 50/60 Hz
    • Contactor Application : control circuit
    • Product Or Component Type : auxiliary contactor
    • Product Name : TeSys CAD || TeSys Deca
    • Range : TeSys || TeSys Deca
    • Pole Contact Composition : 3 NO + 2 NC
    • Connections - Terminals : 1 x 1-4 mm²flexible with cable end || 1 x 1-4 mm²flexible without cable end || 1 x 1-4 mm²solid without cable end || 2 x 1-2.5 mm²flexible with cable end || 2 x 1-4 mm²flexible without cable end
    • Utilisation Category : AC-14 || AC-15
    • Quantity Per Set : set of 10
    • Suppressor Technology : without built-in
    • Device Short Name : CAD
    • Coil Type : standard