Analog isolated high level input module, Modicon X80, 8 inputs, 0 to 20mA, 4 to 20mA, 10V positive or negative

ANA 8 U/I IN ISOLATED FAST

SQDBMXAMI0810 BMXAMI0810 3595864081564
1047.09 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Warranty Length: 18 mth
This high level analog input module is part of the Modicon X80 modules. It has 8 isolated analog inputs (15 bits + sign). This module is connected via 28-way removable terminal block. The module offers different ranges of voltage or current for each of the inputs depending on configuration choice. It occupies a single slot on the rack and it has a case which provides IP 20 protection of the electronics.
QTY
  • Product Description
  • Features
  • Specifications
This high level analog input module is part of the Modicon X80 modules. It has 8 isolated analog inputs (15 bits + sign). This module is connected via 28-way removable terminal block. The module offers different ranges of voltage or current for each of the inputs depending on configuration choice. It occupies a single slot on the rack and it has a case which provides IP 20 protection of the electronics.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Conversion Value : +/- 11.4 V +/- 10 V, +/- 11.4 V +/- 10 V, +/- 11.4 V 0...10 V, +/- 11.4 V 0...10 V, +/- 11.4 V 0...5 V, +/- 11.4 V 0...5 V, +/- 11.4 V 1...5 V, +/- 11.4 V 1...5 V, +/- 11.4 V +/- 10 V, +/- 11.4 V +/- 10 V, +/- 11.4 V 0...10 V, +/- 11.4 V 0...5 V, +/- 11.4 V 1...5 V, 0...30 mA +/- 20 mA, 0...30 mA 0...20 mA, 0...30 mA 4...20 mA, 0...30 mA +/- 5 V
    • Minimum Crosstalk Attenuation : 80 dB
  • Important Information Attributes
    • Persona Type Ids : EU, OM8, SI
    • Persona Type Names : End User, OEM - Control Panelbuilder, System Integrator
    • Current Consumption : 150 mA 3.3 V DC, 54 mA 24 V DC
    • Digital Value Format : - 32768 to + 32767 in maximum user scale, +/- 10000 by default, - 32768 to + 32767 in maximum user scale, +/- 10000 by default
    • Electrical Connection : 28 ways 1 connector
    • Isolation Voltage : 300 V DC between channels, 1400 V DC between channels and ground, 1400 V DC between channels and bus
    • Measurement Error : <= 0.1 % of full scale +/- 10 V 0...60 °C, <= 0.1 % of full scale +/- 10 V 0...60 °C, <= 0.1 % of full scale +/- 10 V 0...60 °C, <= 0.1 % of full scale +/- 5 V 0...60 °C, <= 0.1 % of full scale +/- 5 V 0...60 °C, <= 0.1 % of full scale +/- 5 V 0...60 °C, <= 0.1 % of full scale 0...10 V 0...60 °C, <= 0.1 % of full scale 0...10 V 0...60 °C, <= 0.1 % of full scale 0...10 V 0...60 °C, <= 0.1 % of full scale 0...5 V 0...60 °C, <= 0.1 % of full scale 0...5 V 0...60 °C, <= 0.1 % of full scale 0...5 V 0...60 °C, <= 0.1 % of full scale 1...5 V 0...60 °C, <= 0.1 % of full scale 1...5 V 0...60 °C, <= 0.1 % of full scale 1...5 V 0...60 °C, <= 0.3 % of full scale +/- 20 mA 0...60 °C, <= 0.3 % of full scale +/- 20 mA 0...60 °C, <= 0.3 % of full scale +/- 20 mA 0...60 °C, <= 0.3 % of full scale 0...20 mA 0...60 °C, <= 0.3 % of full scale 0...20 mA 0...60 °C, <= 0.3 % of full scale 0...20 mA 0...60 °C, <= 0.3 % of full scale 4...20 mA 0...60 °C, <= 0.3 % of full scale 4...20 mA 0...60 °C, <= 0.3 % of full scale 4...20 mA 0...60 °C, 0.15 % of full scale 0...20 mA 25 °C, 0.15 % of full scale 4...20 mA 25 °C, 0.075 % of full scale 0...10 V 25 °C, 0.075 % of full scale 0...5 V 25 °C, 0.075 % of full scale 1...5 V 25 °C, 0.075 % of full scale +/- 5 V 25 °C<= 0.1 % of full scale +/- 10 V 0...60 °C, <= 0.1 % of full scale +/- 10 V 0...60 °C, <= 0.1 % of full scale +/- 10 V 0...60 °C, <= 0.1 % of full scale +/- 5 V 0...60 °C, <= 0.1 % of full scale 0...10 V 0...60 °C, <= 0.1 % of full scale 0...5 V 0...60 °C, <= 0.1 % of full scale 1...5 V 0...60 °C, <= 0.3 % of full scale +/- 20 mA 0...60 °C, <= 0.3 % of full scale +/- 20 mA 0...60 °C, <= 0.3 % of full scale 0...20 mA 0...60 °C, <= 0.3 % of full scale 4...20 mA 0...60 °C, 0.15 % of full scale +/- 20 mA 25 °C, 0.075 % of full scale +/- 10 V 25 °C
    • Measurement Resolution : 0.36 mV +/- 10 V, 0.36 mV 0...10 V, 0.36 mV 0...5 V, 0.36 mV 1...5 V, 0.36 mV +/- 5 V, 1.4 µA +/- 20 mA, 1.4 µA 0...20 mA, 1.4 µA 4...20 mA
    • Power Consumption In W : 1.06 W 24 V DC typical, 1.50 W 24 V DC maximum, 0.32 W 3.3 V DC typical, 0.48 W 3.3 V DC maximum
    • Product Or Component Type : analog input module
    • Status Led : 1 LED (Green) RUN, 1 LED per channel (Green) channel diagnostic, 1 LED (Red) ERR, 1 LED (Red) I/O
    • Temperature Drift : 30 ppm/°C +/- 10 V, 30 ppm/°C +/- 5 V, 30 ppm/°C 0...10 V, 30 ppm/°C 0...5 V, 30 ppm/°C 1...5 V, 50 ppm/°C +/- 20 mA, 50 ppm/°C 0...20 mA, 50 ppm/°C 4...20 mA
    • Carbon Footprint Of The Distribution Phase A4 : 0.021576, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.3 kg CO2 eq., 0.29278
    • Carbon Footprint Of The Installation Phase A5 : 0.043936, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 21 kg CO2 eq., 21.082
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 92 kg CO2 eq., 92.011
    • Certificate Agency : CE, RCM, CSA, EAC, Merchant Navy, UL
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-25
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Manufacturing Carbon Footprint : 21.082
    • Use Carbon Footprint : 92.011
    • Weee Scope : Out
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2311046EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2438
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Analog Digital Conversion : 16 bits
    • Common Mode Rejection : 80 dB
    • Fast Read Cycle Time : 1 ms + 1 ms x number of channels used
    • Mtbf Reliability : 900000 H
    • Nominal Read Cycle Time : 9 ms for 8 channels
    • Precision Of Internal Conversion Resistor : 0.1 % - 15 ppm/°C
    • Product Availability : Stock - Normally stocked in distribution facility
    • Protective Treatment : standard version
    • Range Of Product : Modicon X80
    • Returnability : Yes
    • Shock Resistance : 30 gn
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 113 kg CO2 eq.
    • Type Of Filter : first order digital filtering
    • Vibration Resistance : 3 gn
    • Warranty In Months : 18
    • Pep Code : ENVPEP2311046EN
    • Database Version : 2022-01
    • Pep Verification Date : 2023-11-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : referent product
    • Functional-unit Description : The Modicon M X80 range has a long life cycle for about more than 10 years with a 100% use rate. Typical electrical power is 1.79W (150 mA 3.3 V DC). The module offers the following ranges of voltage and current :& 10Voltage range: +/-5 V/+/-10 V/0..5 V/0..10 V/1..5 V,& 10Current range: +/-20 mA/0..20 mA/4..20 mA& 10& 10IP Degree of Protection: IP20& 10IEC 61010-2-201, IEC 61131-2,UL 61010-2-201,CSA C22.2 No 61010-2-201
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 141.1236
    • Energy Model - Manufacturing [A1-a3] : Energy model used: Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; US / Electricity Mix; Production mix; Low voltage; UE-27 / Electricity Mix; Production mix; Low voltage; APAC / Electricity Mix; Production mix; Low voltage; AUS
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; US / Electricity Mix; Production mix; Low voltage; UE-27 / Electricity Mix; Production mix; Low voltage; APAC / Electricity Mix; Production mix; Low voltage; AUS
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; US / Electricity Mix; Production mix; Low voltage; UE-27 / Electricity Mix; Production mix; Low voltage; APAC / Electricity Mix; Production mix; Low voltage; AUS
    • Recyclability Potential, In % : 3
    • Water Use (M3 Eq); Total Life Cycle : 535903
    • Offer Owner Code : 190786
    • Pn : 1
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Manufacturing [A1-a3] : 21.062
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 91.951
    • Climate Change - Total ( Kg Co2 Eq.) Manufacturing [A1-a3] : 21.082
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 92.011
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 249.6
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 1702
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4] : 2.2102
    • Ecotoxicity (Fresh Water) (Ctue) Manufacturing [A1-a3] : 267.09
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 1368.6
    • Ecotoxicity (Fresh Water) (Ctue) End Of Life [C1-c4] : 86.541
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 101.02
    • Hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 2.2234
    • Impacts Related To Land Use/Soil Quality (-) Total Life Cycle : 1330568
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Total Life Cycle : 4667711
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Manufacturing [A1-a3] : 44586
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 42211
    • Marine Aquatic Eutrophication (Kg Of N Equiv) Operational Energy Use [B6] : 0.0655
    • Materials For Recycling (Kg) Installation [A5] : 0.006
    • Net Use Of Fresh Water (M3) Total Life Cycle : 1375403
    • Net Use Of Fresh Water (M3) Manufacturing [A1-a3] : 0.1361
    • Net Use Of Fresh Water (M3) End Of Life [C1-c4] : 11553
    • Non-hazardous Waste Disposed Of (Kg) Total Life Cycle : 203294
    • Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 56586
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 14539
    • Non-hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -0.1723
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 1954.26
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 249.6
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 1702
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4] : 22102
    • Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle : 2169952
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 258.99
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 1908.1
    • Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4] : 24029
    • Total Use Of Primary Energy During The Life Cycle (Mj) Benefits/Loads Beyond System Boundaries [D] : -0.5349
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 2156933
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 93911
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 206.1
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4] : 0.1927
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 27309
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 27309
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 1951.53
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 246.87
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1702
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 22102
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 2150311
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 87289
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 206.1
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 0.1927
    • Water Use (M3 Eq) Manufacturing [A1-a3] : 58454
    • Water Use (M3 Eq) Operational Energy Use [B6] : 36028
    • Water Use (M3 Eq) End Of Life [C1-c4] : 44137
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Directives : 2014/35/EU - low voltage directive, 2014/30/EU - electromagnetic compatibility
    • Operating Altitude : 0...6561.68 ft (0...2000 m), 2000...5000 m with derating factor
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 113.451292
    • Ambient Air Temperature For Operation : 0-60 °C
    • Circularity Profile : ENVEOLI2311046EN
    • Environmental Disclosure : ENVPEP2311046EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % 55-55 °C without condensation
    • Pep Code : ENVPEP2311046EN
    • Pep Verification Date : 2023-11-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : analog input module
    • Range Of Product : Modicon X80
  • ETIM
    • ETIM 8 : EC001420
    • ETIM 9 : EC001420
  • Surge Protection And Filtering Attributes
    • Type Of Filter : first order digital filtering
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Analogue Input Type : current +/- 20 mA, current 0...20 mA, current 4...20 mA, voltage +/- 10 V, voltage +/- 5 V, voltage 0...10 V, voltage 0...5 V, voltage 1...5 V
    • Input Impedance : 10 MOhm in voltage mode, 250 Ohm + 3.6...50 Ohm internal protective resistor in current mode
    • Input Output Isolation : isolated, isolated
    • Permitted Overload On Inputs : +/- 30 mA 0...20 mA, +/- 30 mA 0...20 mA, +/- 30 mA 4...20 mA, +/- 30 mA 4...20 mA, +/- 30 V +/- 10 V, +/- 30 V +/- 10 V, +/- 30 V +/- 5 V, +/- 30 V +/- 5 V, +/- 30 V 0...10 V, +/- 30 V 0...10 V, +/- 30 V 0...5 V, +/- 30 V 0...5 V, +/- 30 V 1...5 V, +/- 30 V 1...5 V, +/- 30 mA +/- 20 mA, +/- 30 mA +/- 20 mA, +/- 30 mA 0...20 mA, +/- 30 mA 0...20 mA, +/- 30 mA 4...20 mA, +/- 30 V +/- 10 V, +/- 30 V +/- 10 V, +/- 30 V +/- 5 V, +/- 30 V 0...10 V, +/- 30 V 0...5 V, +/- 30 V 1...5 V, +/- 30 mA +/- 20 mA
    • Analogue Input Number : 8
    • Analogue Input Resolution : 15 bits + sign
    • Input Level : high level
  • Specifications
    • Country of Origin : France