NEMA Contactor, Type S, nonreversing, Size 00, 9A, 3 HP at 550 VAC, 3 phase, up to 100 kA, 3 pole, 208 VAC coil, NEMA 1

CONTACTOR 600VAC 9AMP NEMA +OP

SQD8502SAG12V08 8502SAG12V08 785901836452
365.66 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, UL Listed File E78351 CCN NLDX
  • Contact Configuration: Without
  • Depth: 134 mm
  • Height: 254 mm
  • Line Rated Current: 9 A
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 152 mm
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 00 non-reversing contactor has a 9 ampere rating. Three phase NEMA Size 00 contactors have 1.5 HP at 200 and 230 VAC and 2 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 208 VAC 60 Hz coil that is wired for common control. This NEMA contactor is in a NEMA 1 general purpose enclosure. This enclosure is 10.00 inches tall, 6.00 inches wide and 5.28 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
QTY
  • Product Description
  • Specifications
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 00 non-reversing contactor has a 9 ampere rating. Three phase NEMA Size 00 contactors have 1.5 HP at 200 and 230 VAC and 2 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 208 VAC 60 Hz coil that is wired for common control. This NEMA contactor is in a NEMA 1 general purpose enclosure. This enclosure is 10.00 inches tall, 6.00 inches wide and 5.28 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Specifications
    • Range Of Product : 8502S
    • Contactor Application : non-reversing
    • Product Or Component Type : contactor
  • Contractual warranty
    • Warranty : 18 months
  • Environmental
    • Product Certifications : UL listed file E78351 CCN NLDX || CSA
    • Nema Degree Of Protection : NEMA 1 painted sheet steel
  • Complementary
    • Local Signalling : no indicator
    • Height : 254 mm
    • Auxiliary Contact Composition : without
    • Nema Size : 00
    • [Uc] Control Circuit Voltage : 208 V AC 60 Hz
    • Poles Description : 3P
    • Rated Power In Hp : 1.5 HP 200 V AC || 1.5 HP 230 V AC || 2 HP 460 V AC || 2 HP 575 V AC
    • Electrical Connection : screw clamp terminals
    • Provided Equipment : fuse not supplied
    • Product Compatibility : circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC || fuse J 60 A maximum, SCCR: 100 kA at 600 V AC || fuse T 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC
    • Line Rated Current : 9 A
    • Control Type : no control units
    • Control Circuit : common control circuit
    • Width : 152 mm
    • Depth : 134 mm
    • Phase : 3 phase
    • [Ue] Rated Operational Voltage : 600 V AC
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Eu Rohs Directive : Not compliant
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov