Tesys motor starter kit, LC1D09BD contactor, LR9D08 thermal overload relay

Tesys motor starter kit, LC1D0

SQDLR9D08KITD09BD LR9D08KITD09BD 3606486288092
151.28 / EA
http://schema.org/OutOfStock
  • Dielectric Strength: 50 Hz, 6 kV
  • Height: 3.03 in
  • Width: 1.77 in
TeSys motor starter kits combine a TeSys LC1D contactor and a TeSys LR9D overload relay to make an IEC starter. This starter has a LC1D09BD contactor and a LR9D08 electronic overload relay. The LC1D09BD contactor has a 9 ampere resistive and horsepower ratings. The LR9D08 electronic overload relay has a current setting of 1.6 to 8 amperes. This starter is UL listed and CSA certified.
QTY
  • Product Description
  • Specifications
TeSys motor starter kits combine a TeSys LC1D contactor and a TeSys LR9D overload relay to make an IEC starter. This starter has a LC1D09BD contactor and a LR9D08 electronic overload relay. The LC1D09BD contactor has a 9 ampere resistive and horsepower ratings. The LR9D08 electronic overload relay has a current setting of 1.6 to 8 amperes. This starter is UL listed and CSA certified.
  • Complementary Attributes
    • Control Circuit Voltage Limits : drop-out 0.1...0.25 Uc DC 60 °C), operational 0.7...1.25 Uc DC 60 °C)
    • Irms Rated Making Capacity : 250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Maximum Horse Power Rating : 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors1 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
    • Ue Rated Operational Voltage : 690 V power circuit, 660 V signalling circuit, power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
    • Ui Rated Insulation Voltage : signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 1000 V, signalling circuit 690 V, power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1
    • Uimp Rated Impulse Withstand Voltage : 6 kV, 6 kV IEC 60947
    • Control Circuit Type : DC standard
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 250 A at 440 V for power circuit conforming to IEC 60947
    • Uc Control Circuit Voltage : 24 V DC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 5 A gG signalling circuit, 5 A BS signalling circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at <= 690 V coordination type 1 for power circuit, 20 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : motor control, resistive load
    • Control Type : Red push-button stop and manual reset, White 2 microswitches adjustable trip class, Red knob automatic reset, White dial full-load current adjustment
    • Electromagnetic Compatibility : surge withstand 2 kV common mode IEC 61000-4-5, resistance to electrostatic discharge 8 kV IEC 61000-4-2, immunity to radiated radio-electrical interference 10 V/m IEC 61000-4-3, immunity to fast transients 2 kV IEC 61000-4-4
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations 10...150 Hz 6 Gn) IEC 60068-2-6, shocks 11 ms 15 gn) IEC 60068-2-7, vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
    • Motor Power Kw : 2.2 kW at 220...230 V AC 50/60 Hz (AC-3), 4 kW at 380...400 V AC 50/60 Hz (AC-3), 4 kW at 415...440 V AC 50/60 Hz (AC-3), 5.5 kW at 500 V AC 50/60 Hz (AC-3), 5.5 kW at 660...690 V AC 50/60 Hz (AC-3), 2.2 kW at 400 V AC 50/60 Hz (AC-4)
    • Mounting Support : under contactor, plate, with specific accessories, rail, with specific accessories, plate, rail
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 53.55...72.45 ms closing, 16...24 ms opening
    • Power Dissipation Per Pole : 1.56 W AC-1, 0.2 W AC-3
    • Power Range : 1.1-2 kW 200-240 V 3 phase, 2.2-3 kW 380-440 V 3 phase, 4-6 kW 380-440 V 3 phase, 4-6 kW 480-500 V 3 phase
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals Philips No 2control circuit 0.8 N.m screw clamp terminals, power circuit 3.1 N.m screw clamp terminals, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
    • Utilisation Category : AC-4, AC-1, AC-3
    • Connections Terminals : power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, power circuit screw clamp terminals 2 1-4 mm²solid without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid without cable end, control circuit screw clamp terminals 2 1-4 mm²solid without cable endcontrol circuit screw clamp terminals 1 2.5-2.5 mm² solid or flexible - without cable end, power circuit screw clamp terminals 1 16-16 mm² solid or flexible - without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²solid without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end
    • Ith Conventional Free Air Thermal Current : 5 A signalling circuit, 25 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
    • Certificate Agency : LROS (Lloyds register of shipping), CSA, UL, GOST, DNV, CCC, GL, BV, RINA, TÜV, CSA, cULus, CCC
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1502001EN
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2020
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Contact Compatibility : M4
    • Contactor Coil Voltage : 24 V DC standard
    • Dielectric Strength : 6 kV 50 Hz IEC 60255-5
    • Energy Efficiency Optimized : False
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Hold In Power Consumption In W : 5.4-5.4 W 20 °C
    • Inrush Power In W : 5.4-5.4 W 20 °C)
    • Mechanical Durability : 30 Mcycles
    • Motor Starter Type : direct on-line contactor
    • Number Of Poles : 3P
    • Overvoltage Category : III
    • Phase Failure Sensitivity : phase difference > 40% 3-3 s IEC 60947-4-1
    • Pole Contact Composition : 3 NO
    • Power Consumption In W : 300 mW
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : motor starter
    • Protective Treatment : TH IEC 60068-2-30
    • Range : TeSys
    • Relay Application : motor protection
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : No
    • Thermal Overload Class : class 5…30
    • Thermal Protection Adjustment Range : 0.4-2 A
    • Time Constant : 28 ms
    • Time Range : 1.5...4 min - automatic reset time
    • Tripping Threshold : 1.25 In IEC 60947-4-1
    • Warranty In Months : 18
    • Pep Code : ENVPEP1502001EN
    • Height Nominal : 72.5 mm
    • Height Useful : 77 mm
    • Width Nominal : 45 mm
    • Width Real : 45 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -25-70 °C IEC 60255-8, -25-70 °C IEC 60255-8, -5-60 °C, -5-60 °C, -25-70 °C IEC 60255-8, -25-70 °C IEC 60255-8
    • Ip Degree Of Protection : front face IP20 IEC 60529, front face IP20 VDE 0106, IP20 front face IEC 60529
    • Operating Altitude : 6561.68 ft (2000 m) without derating, 9842.52 ft (3000 m) without derating
    • Permissible Ambient Air Temperature Around The Device : -40-70 °C at Uc, -40-70 °C at Uc-40-70 °C at Uc, -40-70 °C at Uc
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Ambient Air Temperature For Storage : -60-80 °C-60-80 °C
    • Circularity Profile : ENVEOLI1502001EN
    • Environmental Disclosure : ENVPEP1502001EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Pep Code : ENVPEP1502001EN
  • General Attributes
    • Product Or Component Type : motor starter
  • Specifications
    • Country of Origin : China, United States
    • Height : 3.03 in
    • Width : 1.77 in