Combination motor starter, TeSys Ultra, self protected, full voltage nonreversing, NEMA size 1

TESYS U FVNR NEMA SZ 1 SELF PR

SQDLUB32NR LUB32NR 3389118367234
568.06 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 126 mm
  • Height: 154 mm
  • Net Weight: 0.9 kg
  • Weight: 0.9 kg
  • Width: 45 mm
TeSys U motor starters are integrated starters. TeSys U can be configured to fit specific applications. This TeSys U standard power base has 3 poles that are rated 32A at 600V. This power base is rated for 7.5HP at 200-208VAC, 7.5HP at 240VAC, 10HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. Power base is rated NEMA Size 1. Power base has screw clamp terminals which are non-removable. The power base is 6.42 inches tall, 1.77 inches wide and 5.31 inches deep. Power base is UL Listed and CSA Certified.
QTY
  • Product Description
  • Specifications
TeSys U motor starters are integrated starters. TeSys U can be configured to fit specific applications. This TeSys U standard power base has 3 poles that are rated 32A at 600V. This power base is rated for 7.5HP at 200-208VAC, 7.5HP at 240VAC, 10HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. Power base is rated NEMA Size 1. Power base has screw clamp terminals which are non-removable. The power base is 6.42 inches tall, 1.77 inches wide and 5.31 inches deep. Power base is UL Listed and CSA Certified.
  • Complementary
    • Product Certifications : CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
    • Height : 154 mm
    • Nema Size : 1
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Maximum Operating Rate : 3600 cyc/h
    • Connections - Terminals : control circuit screw clamp terminals 1 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² rigid || power circuit screw clamp terminals 1 1-10 mm² rigid || power circuit screw clamp terminals 1 1-6 mm² flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² rigid || power circuit screw clamp terminals 2 1.5-6 mm² flexible without cable end
    • Net Weight : 0.9 kg
    • Fixing Mode : clipped (DIN rail) || screw-fixed (plate)
    • [Uimp] Rated Impulse Withstand Voltage : 6 kVIEC 60947-6-2
    • Standards : EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
    • [Ui] Rated Insulation Voltage : 690 V IEC 60947-6-2 3) || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
    • Typical Current Consumption : 200 mA 24 V DC I maximum while closing with LUCM || 220 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 220 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 25 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 25 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 45 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 45 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 75 mA 24 V DC I rms sealed with LUCM || 80 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 90 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
    • Mechanical Durability : 15 Mcycles
    • Compatibility Code : LUB
    • Operating Time : 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit || 50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 65 ms closing with LUCM control circuit
    • Width : 45 mm
    • Tightening Torque : control circuit: 0.8-1.2 N.m flat screwdriver 5 mm || control circuit: 0.8-1.2 N.m Philips no 1 screwdriver 5 mm || power circuit: 1.9-2.5 N.m flat screwdriver 6 mm || power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6 mm || power circuit: 1.9-2.5 N.m pozidriv No 2 screwdriver 6 mm
    • Safe Separation Of Circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
    • Depth : 126 mm
    • Heat Dissipation : 3-3 W control circuit with LUCA, LUCB, LUCC, LUCD || 1.8-1.8 W control circuit with LUCM
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2406038EN
    • Halogen Content Performance : Product contains halogen above thresholds
    • Packaging Without Single Use Plastic : Yes
    • Toxic Heavy Metal Free : Yes
    • Scip Number : 61f5a085-dfde-4214-b2cf-ba3cfe0c33b4
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Circularity Profile : ENVEOLI2406038EN
    • Take-Back : No
    • Pvc Free : Yes
    • Sustainable Packaging : Yes
    • Global Warming ; Total Life Cycle​ : 30 kg CO2 eq.
    • Eu Rohs Directive : Compliant
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 29.51458439819237
  • Environment
    • Ambient Air Temperature For Operation : -25-60 °C with LUCM || -25-70 °C with LUCA, LUCB, LUCC, LUCD
    • Resistance To Radiated Fields : 10 V/m 3 IEC 61000-4-3
    • Non-Dissipating Shock Wave : 1 kV serial mode 24...240 V AC IEC 60947-6-2 || 1 kV serial mode 48...220 V DC IEC 60947-6-2 || 2 kV common mode 24...240 V AC IEC 60947-6-2 || 2 kV common mode 48...220 V DC IEC 60947-6-2
    • Shock Resistance : 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
    • Immunity To Microbreaks : 3 ms control circuit
    • Immunity To Voltage Dips : 70 % / 500 ms IEC 61000-4-11
    • Vibration Resistance : 2 gn 5-300 Hz) power poles open IEC 60068-2-27 || 4 gn 5-300 Hz) power poles closed IEC 60068-2-27
    • Ambient Air Temperature For Storage : -40-85 °C
    • Protective Treatment : TH IEC 60068
    • Resistance To Electrostatic Discharge : 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
    • Ip Degree Of Protection : IP20 IEC 60947-1 front panel and wired terminals) || IP20 IEC 60947-1 other faces) || IP40 IEC 60947-1 front panel outside connection zone)
    • Fire Resistance : 960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
    • Immunity To Radioelectric Fields : 10 V IEC 61000-4-6
    • Resistance To Fast Transients : 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
    • Operating Altitude : 6561.68 ft (2000 m)
  • Specifications
    • Country of Origin : United States
    • Width : 45 mm
    • Height : 154 mm
    • Weight : 0.9 kg
    • [Ics] Rated Service Breaking Capacity : 50 kA 230 V || 50 kA 440 V || 10 kA 500 V || 4 kA 690 V
    • [Ue] Rated Operational Voltage : 690 V AC power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • [Uc] Control Circuit Voltage : 24 V AC 50/60 Hz || 24 V DC || 48...72 V AC 50/60 Hz || 48...72 V DC || 110...240 V AC 50/60 Hz || 110...220 V DC
    • Product Or Component Type : non reversing power base
    • [Ith] Conventional Free Air Thermal Current : 32 A
    • Product Name : TeSys Ultra
    • Range : TeSys
    • Utilisation Category : AC-43 || AC-44 || AC-41
    • [Ie] Rated Operational Current : 28.5 A <= 440 V || 23 A 500 V || 21 A 690 V
    • Suitability For Isolation : yes
    • Auxiliary Contacts Type : linked contacts 1 NO + 1 NC) IEC 60947-4-1 || mirror contact 1 NC) IEC 60947-1
    • Poles Description : 3P
    • Network Frequency : 40...60 Hz
    • Device Application : motor control || motor protection
    • Device Short Name : LUB