Reversing Contactor, TeSys Deca, 3P(3NO), AC-3, IEC, <=440V, 50A, 120V AC 60Hz coil

REVERSING CONTACTOR 575VAC 50A

SQDLC2D50G7 LC2D50G7 3389110456677
1128.39 / EA
http://schema.org/OutOfStock
  • Country of Origin: Czechia
  • Depth: 142 mm
  • Height: 132 mm
  • Net Weight: 2.4 kg
  • Warranty Length: 18 mth
  • Weight: 2.4 kg
  • Width: 165 mm
TeSys Deca reversing contactor, 3 poles (3NO),for motor control applications 50A/440V,AC-3/3e 22kW@400V. Pre-wired power connections, with mechanical interlock,without electrical interlocking. It provides a 120V 60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Compact (90mm width), with DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca reversing contactor, 3 poles (3NO),for motor control applications 50A/440V,AC-3/3e 22kW@400V. Pre-wired power connections, with mechanical interlock,without electrical interlocking. It provides a 120V 60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Compact (90mm width), with DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : GL || UL || RINA || GOST || CSA || LROS (Lloyds register of shipping) || CCC || DNV || BV || UKCA
    • Ambient Air Temperature For Operation : -5-60 °C
    • Standards : IEC 60947-4-1 || CSA C22.2 No 14 || UL 508 || IEC 60947-5-1 || EN 60947-4-1 || EN 60947-5-1
    • Shock Resistance : 10 gn contactor closed || 8 gn contactor opened
    • Vibration Resistance : 2 gn 5-300 Hz contactor opened || 3 gn 5-300 Hz contactor closed
    • Ambient Air Temperature For Storage : -60-80 °C
    • Protective Treatment : TH 3)IEC 60068
    • Ip Degree Of Protection : IP2X IEC 60529 || IP2X VDE 0106
    • Operating Altitude : 9842.52 ft (3000 m) without derating
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Permissible Ambient Air Temperature Around The Device : -40-70 °C at Uc
    • Heat Dissipation : 6-10 W at 50/60 Hz for control circuit
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110205EN
    • Packaging Without Single Use Plastic : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Circularity Profile : N/A
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 122.51951604319157
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 11.128831172392866
    • Carbon Footprint Of The Distribution Phase [A4] : 2 kg CO2 eq.
    • Pvc Free : Yes
    • Carbon Footprint Of The Installation Phase [A5] : 0.1 kg CO2 eq.
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 139 kg CO2 eq.
    • Eu Rohs Directive : Compliant
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 3.3499102744611307
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 139.43908435247934
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
    • Interlocking Type : mechanical
    • Minimum Switching Current : 5 mA for control circuit
    • [Ue] Rated Operational Voltage : power circuit <= 1000 V AC 25...400 Hz
    • Height : 132 mm
    • Power Dissipation Per Pole : 3.7 W AC-3 - Ith 80 A
    • Average Impedance : - Ith 80 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Control Circuit Voltage Limits : drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C) || operational: 0.8...1.1 Uc at 50 Hz (at <60 °C) || operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for control circuit || 80 A (at 60 °C) for power circuit
    • Mounting Support : plate || rail
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Insulation Resistance : > 10 MOhm for control circuit
    • Rated Breaking Capacity : 900 A at 440 V for power circuit conforming to IEC 60947
    • Irms Rated Making Capacity : 140 A AC for control circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
    • Associated Fuse Rating : 10 A gG for control circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
    • Net Weight : 2.4 kg
    • Inrush Power In Va : 200-200 VA cos phi 0.75 (at 20 °C) || 220-220 VA cos phi 0.75 (at 20 °C)
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Flame Retardance : V1 conforming to UL 94
    • Minimum Switching Voltage : 17 V for control circuit
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Tightening Torque : control circuit 1.7 N.m 1-2.5 mm² flat Ø 6 mm || control circuit 1.7 N.m 1-2.5 mm² Philips No 2 || control circuit 1.7 N.m 1-4 mm² flat Ø 6 mm || control circuit 1.7 N.m 1-4 mm² Philips No 2 || power circuit 5 N.m 1-25 mm² hexagonal || power circuit 8 N.m 1-35 mm² hexagonal
    • Assembly Style : ready assembled
    • Mechanical Durability : 6000000 cycles
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Hold-In Power Consumption In Va : 20-20 VA 50 Hz cos phi 0.3 (at 20 °C) || 22-22 VA 60 Hz cos phi 0.3 (at 20 °C) || 26-26 VA 50 Hz cos phi 0.3 (at 20 °C) || 26-26 VA 60 Hz cos phi 0.3 (at 20 °C)
    • Operating Time : 12...26 ms closing || 4...19 ms opening
    • Width : 165 mm
    • Overvoltage Category : III
    • Depth : 142 mm
    • [Ui] Rated Insulation Voltage : control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
    • Protective Cover : with
  • Specifications
    • Country of Origin : Czechia
    • Width : 165 mm
    • Height : 132 mm
    • Weight : 2.4 kg
    • Control Circuit Type : AC
    • [Uc] Control Circuit Voltage : 120 V AC 60 Hz
    • Range Of Product : TeSys Deca
    • Contactor Application : motor control
    • Product Or Component Type : reversing contactor
    • Connections - Terminals : control circuit 1 1-4 mm²flexible with cable end || power circuit 2 1-25 mm²flexible with cable end || power circuit 2 1-25 mm²flexible without cable end || power circuit 2 1-25 mm²solid without cable end || power circuit 2 1-35 mm²flexible with cable end || power circuit 2 1-35 mm²flexible without cable end || power circuit 2 1-35 mm²solid without cable end || control circuit 1 1-4 mm²flexible without cable end || control circuit 1 1-4 mm²solid without cable end || control circuit 2 1-2.5 mm²flexible with cable end || control circuit 2 1-4 mm²flexible without cable end || control circuit 2 1-4 mm²solid without cable end || power circuit 1 1-35 mm²flexible with cable end || power circuit 1 1-35 mm²flexible without cable end || power circuit 1 1-35 mm²solid without cable end
    • Pole Contact Composition : 3 NO
    • Utilisation Category : AC-2 || AC-3 || AC-4
    • [Ie] Rated Operational Current : power circuit 50 A AC AC-3 60 °C)
    • Poles Description : 3P
    • Motor Power Kw : 15 kW 220...240 V AC 50/60 Hz || 22 kW 380...400 V AC 50/60 Hz || 25 kW 415 V AC 50/60 Hz || 30 kW 440 V AC 50/60 Hz || 30 kW 500 V AC 50/60 Hz || 33 kW 660...690 V AC 50/60 Hz
    • Device Short Name : LC2D
    • Coil Type : standard