Contactor, Tesys Deca, 3P(3NO),AC-3/AC-3e/<=440V 50A,208V AC 50/60Hz coil, screw clamp terminals

CONTACTOR 600VAC 50AMP IEC +OP

SQDLC1D50LE7 LC1D50LE7 3389110296143
446.98 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys Deca contactor, 3 poles (3NO),for motor control applications 50A/690V,AC-3 33kW@690V. and for non-inductive load control applications up to 80A@60℃ in category AC-1. It provides a 208V 50/60Hz AC coil,1NO/1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO),for motor control applications 50A/690V,AC-3 33kW@690V. and for non-inductive load control applications up to 80A@60℃ in category AC-1. It provides a 208V 50/60Hz AC coil,1NO/1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : CSA C22.2 No 14, UL 60947-4-1, IEC 60947-4-1, IEC 60947-5-1, EN 60947-5-1, EN 60947-4-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
    • IRMS Rated Making Capacity : 900 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for control circuit conforming to IEC 60947-5-1
    • Maximum Horse Power Rating : 3 hp at 115 V AC 60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors, 15 hp at 200/208 V AC 60 Hz for 3 phase motors, 15 hp at 230/240 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 575/600 V AC 60 Hz for 3 phase motors
    • IE Rated Operational Current : 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • UI Rated Insulation Voltage : control circuit 600 V CSA, control circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, control circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-1
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Motor Phase Current : 50 A
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for control circuit
    • Minimum Switching Voltage : 17 V for control circuit
    • Rated Breaking Capacity : 900 A at 440 V for power circuit conforming to IEC 60947
    • UC Control Circuit Voltage : 208 V AC 50/60 Hz
    • UE Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • UIMP Rated Impulse Withstand Voltage : 8 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for control circuit conforming to IEC 60947-5-1, 100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : resistive load, motor control
    • Hold In Power Consumption In VA : 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Inrush Power In VA : 140-140 VA cos phi 0.75 (at 20 °C), 160-160 VA cos phi 0.75 (at 20 °C)
    • Insulation Resistance : > 10 MOhm for control circuit, > 10 MOhm for control circuit
    • Mechanical Robustness : shocks contactor opened 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), vibrations contactor opened 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz)
    • Motor Power KW : 22 kW at 380...400 V AC 50 Hz, 25 kW at 415 V AC 50 Hz, 30 kW at 440 V AC 50 Hz, 30 kW at 500 V AC 50 Hz, 33 kW at 660...690 V AC 50 Hz, 15 kW at 220...230 V AC 50 Hz, 30 kW at 1000 V AC 50 Hz
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contacts, 1.5 ms on energisation between NC and NO contacts
    • Operating Time : 4...19 ms opening, 12...26 ms closing
    • Power Dissipation Per Pole : 3.7 W AC-3, 9.6 W AC-1, 3.7 W AC-3e
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Terminals Description ISO N 1 : (A1-A2)CO, (13-14)NO, (21-22)NC
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminal Philips No 2, power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm, control circuit 1.7 N.m screw clamp terminal pozidriv No 2
    • IE Rated Operational Current : 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • ITH Conventional Free Air Thermal Current : 10 A (at 60 °C) for control circuit, 80 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.1760063361869087, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3.328416174215296, 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.3 kg CO2 eq., 0.2523595925959343
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 9 kg CO2 eq., 8.921945858891672
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 46 kg CO2 eq., 45.50628623188404
    • Connections Terminals : control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: rigid, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end
    • Auxiliaries : LADN22, LADN11, LADN20, LAD8N11, LADT2, LADN40, LADN31, LADN02, LADT0, LAD8N20
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-08
    • HTML Description : TeSys D ContactorNumber of Poles: 3-PolesPole Contact Composition: 3 NOControl Circuit Voltage: 208V AC 50/60 HzDegree of Protection: IP2x
    • Manufacturer : Square D
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Compatibility Code : LC1D
    • Device Short Name : LC1D
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Heat Dissipation : 4-5 W at 50/60 Hz for control circuit
    • Package Weight Lbs : 1.4 kg
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 58 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1102005EN
    • Pep Verification Date : 2025-11-20
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Product Manager : NANNAN YAN
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • IP Degree Of Protection : IP2X IEC 60529, IP2X VDE 0106
    • Reach Regulation : Free of Substances of Very High Concern above the threshold, Reference contains Substances of Very High Concern above the threshold
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 58.18501419377385
    • Climatic Withstand : IACS E10 exposure to damp heat
    • Environmental Disclosure : ENVPEP1102005EN
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Pep Code : ENVPEP1102005EN
    • Pep Verification Date : 2025-11-20
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months