Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 24VDC, without control terminals

12A SELF-PR.REV.STR W/TERMS-LU

SQDLU2BA0BL LU2BA0BL 3389110363098
477.11 / EA
http://schema.org/OutOfStock
  • Depth: 126 mm
TeSys U standard reversing power base, 3 poles (3NO), rated 12A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 5.5kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0BL to be supplied with 24V DC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys U standard reversing power base, 3 poles (3NO), rated 12A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 5.5kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0BL to be supplied with 24V DC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
    • Standards : EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
  • Complementary Attributes
    • Control Circuit Voltage Limits : 14.5 V DC drop-out, 20...27 V DC in operation
    • Ics Rated Service Breaking Capacity : 50 kA 230 V, 50 kA 440 V, 10 kA 500 V, 4 kA 690 V
    • Ie Rated Operational Current : 12 A <= 440 V, 12 A 500 V, 9 A 690 V
    • Ui Rated Insulation Voltage : 690 V IEC 60947-6-2 3), 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
    • Maximum Operating Rate : 3600 cyc/h
    • Uc Control Circuit Voltage : 24 V DC
    • Ue Rated Operational Voltage : 690 V AC power circuit
    • Uimp Rated Impulse Withstand Voltage : 6 kVIEC 60947-6-2
  • Important Information Attributes
    • Device Application : motor control, motor protection
    • Fire Resistance : 960 °C parts supporting live components IEC 60695-2-12, 650 °C IEC 60695-2-12
    • Fixing Mode : clipped (DIN rail), screw-fixed (plate)
    • Heat Dissipation : 2-2 W control circuit with LUCA, LUCB, LUCC, LUCD, 1.7-1.7 W control circuit with LUCM
    • Operating Time : 150 ms with change of direction power circuit, 75 ms without change of direction power circuit, 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 75 ms closing with LUCM control circuit, 70 ms closing with LUCA, LUCB, LUCC, LUCD control circuit
    • Resistance To Electrostatic Discharge : 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
    • Resistance To Fast Transients : 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
    • Safe Separation Of Circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Shock Resistance : 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
    • Tightening Torque : power circuit: 1.9-2.5 N.m flat screwdriver 6 mm, power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6 mm, power circuit: 1.9-2.5 N.m pozidriv No 2 screwdriver 6 mm
    • Typical Current Consumption : 120 mA 24 V DC I maximum while closing, 120 mA 24 V DC I rms sealed
    • Utilisation Category : AC-43, AC-44, AC-41
    • Vibration Resistance : 2 gn 5-300 Hz) power poles open IEC 60068-2-27, 4 gn 5-300 Hz) power poles closed IEC 60068-2-27
    • Connections Terminals : power circuit: screw clamp terminals 2 cable(s) 1-6 mm² rigid, power circuit: screw clamp terminals 1 cable(s) 1-10 mm² rigid, power circuit: screw clamp terminals 1 cable(s) 1-6 mm² flexible with cable end, power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm² flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 1-6 mm² flexible with cable end, power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end, control circuit: without connection
    • Ics Rated Service Breaking Capacity : 50 kA 230 V, 50 kA 440 V, 10 kA 500 V, 4 kA 690 V
    • Ie Rated Operational Current : 12 A <= 440 V, 12 A 500 V, 9 A 690 V
    • Carbon Footprint Of The Distribution Phase A4 : 0.6843699101945505, 0.7 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3.2391501435711954, 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.1 kg CO2 eq., 0.0893852969884094
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 9 kg CO2 eq., 8.698303583482293
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 10 kg CO2 eq., 10.242554388924361
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-08
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2407003EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2023
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Compatibility Code : LU2B
    • Device Short Name : LU2B
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Product contains halogen above thresholds
    • Immunity To Microbreaks : 3 ms control circuit
    • Immunity To Radioelectric Fields : 10 V IEC 61000-4-6
    • Immunity To Voltage Dips : 70 % / 500 ms IEC 61000-4-11
    • Inrush Restraint Duration : 15 ms DC
    • Mechanical Durability : 15 Mcycles
    • Network Frequency : 40...60 Hz
    • Poles Description : 3P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys Ultra
    • Product Or Component Type : reversing power base
    • Protective Treatment : TH IEC 60068
    • Range : TeSys
    • Range Of Product : TeSys Ultra
    • Resistance To Radiated Fields : 10 V/m 3 IEC 61000-4-3
    • Returnability : No
    • Software Version : v6.1
    • Suitability For Isolation : yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 23 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 12 A
    • Warranty In Months : 18
    • Pep Code : ENVPEP2407003EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 1281
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 153.3
    • Energy Model Manufacturing A1 A3 2 : France, FR
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Recyclability Potential In 2 : 58
    • Offer Owner Code : 190788
    • Height Nominal : 224 mm
    • Width Nominal : 45 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -25-60 °C with LUCM, -25-60 °C with LUCM, -25-70 °C with LUCA, LUCB, LUCC, LUCD, -25-70 °C with LUCA, LUCB, LUCC, LUCD, -25-60 °C with LUCM, -25-60 °C with LUCM, -25-70 °C with LUCA, LUCB, LUCC, LUCD
    • Ip Degree Of Protection : IP20 IEC 60947-1 front panel and wired terminals), IP20 IEC 60947-1 other faces), IP40 IEC 60947-1 front panel outside connection zone)
    • Product Compatibility : control unit LUC.X6BL, control unit LUC.1XBL, control unit LUC.05BL, control unit LUC.12BL
    • Take Back : Nej
    • Halogene Performance : Product contains halogen above thresholds
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 22.953763323160807
    • Ambient Air Temperature For Storage : -40-85 °C
    • Circularity Profile : ENVEOLI2407003EN
    • Environmental Disclosure : ENVPEP2407003EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Product contains halogen above thresholds
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2407003EN
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : reversing power base
    • Range Of Product : TeSys Ultra
  • ETIM
    • ETIM 8 : EC001037
    • ETIM 9 : EC001037
  • Specifications
    • Depth : 126 mm