  • Cable Length: 50 m
This RS485 shielded cable is used to connect 2 safe communication expansion modules. It is designed to link two safe communication modules, in order to create decentralized cabinets of remote IO. This cable figures 2 pairs of twisted conductors with shielding with flying lead connection. RS485 serial interface shielded cables are used between the Bus expansion communication modules to create up to six decentralized safety-related islands with a maximum of 50 meters between each island. It weighs 4.6kg. It measures 50m. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
QTY
  • Product Description
  • Features
  • Specifications
This RS485 shielded cable is used to connect 2 safe communication expansion modules. It is designed to link two safe communication modules, in order to create decentralized cabinets of remote IO. This cable figures 2 pairs of twisted conductors with shielding with flying lead connection. RS485 serial interface shielded cables are used between the Bus expansion communication modules to create up to six decentralized safety-related islands with a maximum of 50 meters between each island. It weighs 4.6kg. It measures 50m. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
  • Features
    • Modular safety controller are designed to provide safety solutions requiring conformity to PLe and SIL3
    • Reduce time-to-market: Offers designed specifically meeting the 6 safety functions required on your machine
    • Modicon MCM offers an extensive range of safety products designed to provide protection for personnel and equipment
    • Modicon MCM safety controller are designed for monitoring multiple safety functions
    • Increase profitability: Safety designed from standalone components to embedded safety network solutions
    • Improve efficiency: One partner for the complete safety chain covering the complete range of safety functions
    • Simplify integration: Wide range of connections for machine controllers
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment Attributes Main
    • Take Back : No, Nej
    • China ROHS Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • EU ROHS Directive : Compliant , Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS Exemption Information : Yes
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Ambient Air Temperature For Operation : -20-80 °C
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Product Compatibility : XPSMCMCO0000S...
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Insulation Resistance : 24 MOhm nominal conductor DC resistance, 2.2 MOhm nominal outer shield DC resistance
    • Type Of Cable : twisted pair white/blue, twisted pair orange/white
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-25
    • Serviceability : No
    • Traceability : No
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Attenuation : 1.97 dB
    • AWG Gauge : AWG 24
    • Electrical Connection : flying leads
    • Package Weight Lbs : 3.738 kg
    • Permissible Current : 2.1 A
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Range Of Product : Preventa Safety automation
    • Returnability : No
    • Sustainable Packaging : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ue Rated Operational Voltage2 : 300 Vrms
    • Accessory Separate Part Category2 : cabling accessory
    • Accessory Separate Part Destination2 : RS485 safe communication expansion module
    • Accessory Separate Part Type2 : connecting cable
    • Medium Desc : RS485 shielded cable to build safety islands with safe com. modules - 50 m
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Cable Insulation Material : PE (polyethylene)
    • Cable Shielding Type : S/FTP
    • Delay Skew : 1.54 ns
    • Nominal Velocity Propagation : 66 %
    • Global Commercial Status : Commercialised
  • Physical Attributes
    • Cable Length : 50 m
  • General Attributes
    • Range Of Product : Preventa Safety automation