NEMA Contactor, Type S, nonreversing, Size 2, 45A, 7.5 HP at 230 VAC, 1 phase, up to 100 kA, 2 pole, 240 VAC coil, open

CONTACTOR 600VAC 45AMP NEMA +O

SQD8502SDO1V03 8502SDO1V03 785901757610
939.34 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, UL Listed File E78351 CCN NLDX
  • Contact Configuration: Without
  • Depth: 125.48 mm
  • Height: 130.30 mm
  • Line Rated Current: 45 A
  • NEMA: 2
  • Number of Phases: 1
  • Warranty Length: 18 mth
  • Width: 109.47 mm
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 2 non-reversing contactor has a 45 ampere rating. Single phase NEMA Size 2 contactors have 3 HP at 115 VAC and 7.5 HP at 230 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a stronger 220/240 VAC 50/60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 5.13 inches tall, 4.31 inches wide and 4.94 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
QTY
  • Product Description
  • Specifications
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 2 non-reversing contactor has a 45 ampere rating. Single phase NEMA Size 2 contactors have 3 HP at 115 VAC and 7.5 HP at 230 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a stronger 220/240 VAC 50/60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 5.13 inches tall, 4.31 inches wide and 4.94 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Specifications
    • Range Of Product : 8502S
    • Contactor Application : non-reversing
    • Product Or Component Type : contactor
  • Contractual warranty
    • Warranty : 18 months
  • Environmental
    • Product Certifications : UL listed file E78351 CCN NLDX || CSA
    • Nema Degree Of Protection : not rated (open device)
  • Complementary
    • Local Signalling : no indicator
    • Height : 130.30 mm
    • Auxiliary Contact Composition : without
    • Nema Size : 2
    • [Uc] Control Circuit Voltage : 240 V AC 60 Hz || 220 V AC 50 Hz
    • Poles Description : 2P
    • Rated Power In Hp : 7.5 HP 230 V AC || 3 HP 115 V AC
    • Electrical Connection : screw clamp terminals
    • Provided Equipment : fuse not supplied
    • Product Compatibility : circuit-breaker 100 A maximum, SCCR: 100 kA at 480 V AC || fuse J 100 A maximum, SCCR: 100 kA at 600 V AC || fuse T 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 100 A maximum, SCCR: 100 kA at 600 V AC
    • Line Rated Current : 45 A
    • Control Type : no control units
    • Control Circuit : common control circuit
    • Width : 109.47 mm
    • Depth : 125.48 mm
    • Phase : 1 phase
    • [Ue] Rated Operational Voltage : 600 V AC
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Eu Rohs Directive : Not compliant
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov