Meter mains, Homeline, CSED, ringless socket, 400A, surface mount, maximum 8 spaces, 16 circuits, Class 320 with lever bypass

Meter mains, Homeline, CSED, ringless socket, 400A, surface mount, maximum 8 spaces, 16 circuits, Class 320 with lever bypass

SQDRC816D400SL RC816D400SL 785901335276
1426.17 / EA
http://schema.org/OutOfStock
  • Depth: 7.89 in
Square D™ Meter Mains are single phase power distribution panels used in residential applications where local codes require service disconnects to be located outside the dwelling. The meter socket supports a standard utility meter and a main disconnect breaker which provides a time and space saving solution for contractors and installers. Meter mains are surface mount with provisions. This is for the field installation of the service disconnect(s) that feed devices downstream. Interior subfeed load centers are typically used with these. This CSED is a Homeline ringless type with horn bypass, and combination overhead/underground feed. With a current rating of 400A, this product has a short circuit current rating of 22kA. Single main service disconnects option is also available. Devices meet the Electric Utility Service Equipment Requirements Committee (EUSERC) standards, Federal Specifications W-P-115C for government housing.
QTY
  • Product Description
  • Features
  • Specifications
Square D™ Meter Mains are single phase power distribution panels used in residential applications where local codes require service disconnects to be located outside the dwelling. The meter socket supports a standard utility meter and a main disconnect breaker which provides a time and space saving solution for contractors and installers. Meter mains are surface mount with provisions. This is for the field installation of the service disconnect(s) that feed devices downstream. Interior subfeed load centers are typically used with these. This CSED is a Homeline ringless type with horn bypass, and combination overhead/underground feed. With a current rating of 400A, this product has a short circuit current rating of 22kA. Single main service disconnects option is also available. Devices meet the Electric Utility Service Equipment Requirements Committee (EUSERC) standards, Federal Specifications W-P-115C for government housing.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=RC816D400SL
  • Conformance Attributes
    • Product Certifications : UL E-6294
  • Complementary Attributes
    • Branch Circuit Breaker Rated Current : 30 A, 50 A, 200 A
    • Bus Rated Current : 200.0 A
    • Line Rated Current : 400 A
    • Service Disconnect Rated Current : 200 A
  • Important Information Attributes
    • Persona Type Ids : EU, LC, SC
    • Persona Type Names : End User, Contractor, Electrician
    • Awg Gauge : AWG 4...600 kcmil aluminium/copper), AWG 1/0...350 kcmil 2 aluminium/copper)
    • Service Feed Location : OH, UG
    • Tightening Torque : main lugs 500 lb.in, aluminium/copper, main lugs 500 lb.in, AWG 4/0...600 kcmil, aluminium/copper, service ground 50 lb.in, AWG 14...AWG 1/0, copper, service ground 50 lb.in, AWG 12...AWG 1/0, aluminium, branch lugs 50 lb.in, AWG 3...AWG 2/0, aluminium/copper, branch lugs 45 lb.in, AWG 6...AWG 4, aluminium/copper, branch lugs 40 lb.in, AWG 8, aluminium/copper, branch lugs 35 lb.in, AWG 14...AWG 10, copper, branch lugs 35 lb.in, AWG 12...AWG 10, aluminium, Cover 10 lb.in
    • Carbon Footprint Of The Distribution Phase A4 : 23.196555889027298, 23 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 54 kg CO2 eq., 54.14221836314223
    • Carbon Footprint Of The Installation Phase A5 : 0.4530712629059614, 0.5 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 216 kg CO2 eq., 216.26544319054915
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 220 kg CO2 eq., 219.92644545809503
    • Medium Desc : Meter mains, Homeline, CSED, ringless socket, 400A, surface mount, maximum 8 spaces, 16 circuits, Class 320 with lever bypass
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-02-10
    • Global Commercial Status : End of commerc. - Block
    • Return Indicator : Y
    • Stocking Flag : N
    • H And D Domain : Safety
    • H And D Subrange : RESI
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : ENCLOSURES
    • H And D Enrichment Class 3 : Meter enclosures
    • H And D Enrichment Class 4 : Combination service entrance device
    • Legacy Weee Scope : In
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : RESIDENTIAL
    • Market Segmentation : Residential
    • Product Kit Identifier : N
    • Device Composition : service disconnect (factory installed)
    • Electrical Connection : feed-thru lugs
    • Energy Efficiency Optimized : False
    • Meter Socket Type : ringless
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : Meter Mains
    • Range Of Product : Homeline
    • Returnability : Yes
    • Software Version : v6.2.5-6
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 514 kg CO2 eq.
    • Pep Code : ENVPEP2509019EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-09-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : When a product covered by this PSR includes additional functions, the functional unit defined in the PSR shall be used and shall be completed in order to take into account these additional functionsThe installation must be protected against overloads and short circuits in accordance with the circuit’s rated voltage (Ue), rated current (In), number of poles (Np), rated breaking capacity (Icn), and tripping curve (Cd). The protective device should be capable of establishing, carrying, and interrupting the rated current at the rated voltage. It must be suitable for wall-mounted or enclosure/cabinet installations in household or commercial environments, depending on the intended use. Additionally, the device should be designed to maintain reliable performance throughout a reference service life of 20 years.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; Mexico, MX
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Height Nominal : 32.68 in
    • Width Nominal : 28 in
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 513.9837341637196
    • Environmental Disclosure : ENVPEP2509019EN
    • Eu Rohs Directive : Compliant By Exemption
    • Nema Degree Of Protection : NEMA 3R
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2509019EN
    • Pep Verification Date : 2025-09-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : Meter Mains
    • Range Of Product : Homeline
  • Output Attributes
    • Bypass Type : class 320 lever bypass
  • Specifications
    • Depth : 7.89 in