Monolithic pilot light, Harmony XB7, plastic, red, 22mm, integral LED, 24V AC DC

Harmony XB7, Monolithic pilot

SQDXB7EV04BP XB7EV04BP 3389110839739
25.29 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
This Harmony XB7, plain lens monolithic red pilot light is supplied with 24V AC/DC, uses an integral LED and screw clamp terminals. It is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is clearly distinguishable visually at a distance due to clear colors and illumination via integral LED, enabling complex machine statuses to be read at a glance. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. It has a double insulated plastic bezel. Its wide range of operating temperatures from -25°C to 70°C allows versatility in usage of product.
QTY
  • Product Description
  • Features
  • Specifications
This Harmony XB7, plain lens monolithic red pilot light is supplied with 24V AC/DC, uses an integral LED and screw clamp terminals. It is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is clearly distinguishable visually at a distance due to clear colors and illumination via integral LED, enabling complex machine statuses to be read at a glance. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. It has a double insulated plastic bezel. Its wide range of operating temperatures from -25°C to 70°C allows versatility in usage of product.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • UI Rated Insulation Voltage : 250 V 3)IEC 60947-1, 250 V 3)IEC 60947-1, 250 V 3)IEC 60947-1
    • UIMP Rated Impulse Withstand Voltage : 6 kV IEC 60947-1, 6 kV IEC 60947-1
    • US Rated Supply Voltage : 24 V AC/DC 50/60 Hz, 24 V AC/DC 50/60 Hz, 24 V AC/DC 50/60 Hz
  • Environment Attributes Additional
    • Energy Model Manufacturing A1 A3 : Energy model used: Electricity Mix; Production mix; Low voltage; ID
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 0.0074635712
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.0026556717
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.0000168214
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.0000003718
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 0.0047085211
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.0000821853
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.0000730003
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 0.0023522023
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : 0.0017843513
    • Climate Change Biogenics Kg Co2 Eq Distribution A4 : 0
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.0000012798
    • Climate Change Biogenics Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Biogenics Kg Co2 Eq Repair B3 : 0
    • Climate Change Biogenics Kg Co2 Eq Replacement B4 : 0
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 0.0004889789
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.0000775923
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.0000297833
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 1.1428455197
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 0.358816761
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 0.0026153035
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.0000682079
    • Climate Change Fossil Fuels Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Repair B3 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Replacement B4 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 0.7327394366
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 0.0486058107
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.0128794707
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 1.1451833082
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 0.3606002493
    • Climate Change Total Kg Co2 Eq Distribution A4 : 0.0026153035
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.000069488
    • Climate Change Total Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Total Kg Co2 Eq Repair B3 : 0
    • Climate Change Total Kg Co2 Eq Replacement B4 : 0
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 0.7332147887
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 0.0486834788
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.0129101544
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.000009263
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.0000092408
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000000001
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000000217
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000004
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb BLB SysBound D : -0.0000029212
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 20.1190379781
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 5.9243455748
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 0.0364368588
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.0008668808
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 13.4876408451
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 0.6697478186
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -0.2345191294
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 92.9114263765
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 81.1017355451
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 0.0017599962
    • Ecotoxicity Fresh Water Ctue Installation A5 : 0.0002238757
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 10.7920774648
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 1.0156294947
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -0.3297823377
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.000000048
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.000000019
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.0000000001
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.0000000286
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.0000000003
    • Emission Of Fine Particles Incidence Of Diseases BLB SysBound D : -0.0000000051
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.000003891
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.0000032571
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.000000001
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.0000000002
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.0000006035
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.0000000292
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.00000003
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 0.3664185631
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.325918113
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0000003403
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.0175496831
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0229504267
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.2244989932
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.0000000466
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.0000000465
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.0000000001
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.000000033
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.0000000211
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.0000000162
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.0000000043
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.0000000005
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.0000000005
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 0.0168800268
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 0.0046614249
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0
    • Impacts Related To Land Use Soil Quality Installation A5 : 0
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 0.0067084859
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.005510116
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 0.7137128053
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 0.384677342
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.0000063618
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.0000014488
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 0.3285950704
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 0.0004325822
    • Ionizing Radiation Human Health Kbq Of U235 Equiv BLB SysBound D : -0.0013054943
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.0009575673
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.0003900949
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.0000078998
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.000000151
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.000522
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.0000374216
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0000072682
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 0.0029976987
    • Materials For Recycling Kg Manufacturing A1 A3 : 0
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.0000158213
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.0029818775
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.0160227512
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.0019325918
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000002309
    • Net Use Of Fresh Water M3 Installation A5 : 0.0000002898
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.0006645739
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.0134250647
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.0001279797
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 0.2510429707
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.1225620865
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0000916828
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0000950877
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.1155517606
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0127423531
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.0076461789
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.0000000573
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000000535
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000000035
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000003
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.000000003
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 0.0031210548
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.0013349314
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.0000218938
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.000000395
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 0.0017260352
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.0000377994
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.0000303605
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.000088098
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0000738201
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0000000653
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000000136
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.0000136537
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000005453
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.0000033908
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 0.0107487558
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.004129255
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.0000866699
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.0000015525
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 0.0064086972
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.0001225813
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0000829965
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj TLC : 20.1190379781
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 5.9243455748
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.0364368588
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.0008668808
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 13.4876408451
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.6697478186
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : -0.2345191294
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 22.0711858946
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 6.0606961358
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 0.0364857609
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.0008891361
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 15.3009507042
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 0.6721641576
    • Total Use Of PrE During The Life Cycle Mj BLB SysBound D : -0.2363505609
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj TLC : 1.9521473546
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 0.1363505609
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.0000486231
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.00002226
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 1.8133098592
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.0024160514
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : -0.0018331575
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.6122926455
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.6122926455
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj TLC : 19.5068028644
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Mfg A1 A3 : 5.3121104612
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Dist A4 : 0.0364368588
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Inst A5 : 0.0008668808
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 13.4876408451
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.6697478186
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj BLB SysBound D : -0.2345191294
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.0001862691
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.0001862691
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of RE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of RE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -0.0001917538
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj TLC : 1.9519651703
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Mfg A1 A3 : 0.1361683766
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Dist A4 : 0.0000486231
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Inst A5 : 0.00002226
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj OpEnergy B6 : 1.8133098592
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.0024160514
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj BLB SysBound D : -0.0016413846
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.0000009589
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.0000009589
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electromagnetic Compatibility : disturbing field emission class B conforming to IEC 55011, disturbing field emission class B conforming to IEC 55011, disturbing field emission class B conforming to IEC 55011
    • Fixing Center : >= 30 x 40 mm support panel) metal 1-6 mm, >= 30 x 40 mm support panel) metal 1-6 mm, >= 30 x 40 mm support panel) metal 1-6 mm, >= 30 x 40 mm support panel) metal 1-6 mm, >= 30 x 40 mm support panel) plastic 2-6 mm, >= 30 x 40 mm support panel) plastic 2-6 mm, >= 30 x 40 mm support panel) plastic 2-6 mm, >= 30 x 40 mm support panel) plastic 2-6 mm
    • Fixing Mode : fixing nut beneath head 2-2.4 N.m, fixing nut beneath head 2-2.4 N.m
    • Overvoltage Category : class II conforming to IEC 60536, class II conforming to IEC 60536
    • Service Life : 70000 h at rated voltage and 25 °C, 70000 h at rated voltage and 25 °C
    • Shape Of Screw Head : cross JIS No 1, cross JIS No 1, cross Philips no 1, cross Philips no 1, cross pozidriv No 1, cross pozidriv No 1, slotted flat Ø 4 mm, slotted flat Ø 4 mm, slotted flat Ø 5.5 mm, slotted flat Ø 5.5 mm
    • Shock Resistance : 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
    • Supply Voltage Limits : 19.2-30 V DC, 19.2-30 V DC, 21.6-26.4 V AC, 21.6-26.4 V AC
    • Tightening Torque : 0.8-1.2 N.m IEC 60947-1, 0.8-1.2 N.m IEC 60947-1
    • Vibration Resistance : 5 gn (f= 2-500 Hz) conforming to IEC 60068-2-6, 5 gn (f= 2-500 Hz) conforming to IEC 60068-2-6, 5 gn (f= 2-500 Hz) conforming to IEC 60068-2-6
    • Connections Terminals : screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1, screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1, screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1, screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-13
    • HTML Description : PILOT LIGHT LED 24V RED, 22 mm, 24 V AC/DC 50/60 Hz
    • Manufacturer : Schneider Electric
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2312030EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Bulb Base : integral LED
    • Compatibility Code : XB7
    • Device Short Name : XB7
    • Mounting Diameter : 22 mm
    • Package Weight Lbs : 18.000 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : pilot light
    • Range Of Product : Harmony XB7
    • Returnability : Yes
    • Shape Of Signaling Unit Head : round
    • Signalling Type : steady
    • Sustainable Packaging : No
    • Terminals Description ISO N 1 : (X1-X2)PL
    • Total Lifecycle Carbon Footprint : 1 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2312030EN
    • Pep Verification Date : 2023-12-07
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : XB7 monolithic green pilot light uses an integral LED and screw clamp terminals. It is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is clearly distinguishable visually at a distance due to clear colors and illumination via integral LED, enabling complex machine statuses to be read at a glance. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. It has a double insulated plastic bezel.
    • Product Kit Identifier : N
    • Huella De Carbono De La Fase De Distribución A4 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Fabricación A1 A A3 : 0.4 kg CO2 eq.
    • Huella De Carbono De La Fase De Fin De Vida C1 A C4 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Instalación A5 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Uso B2 B3 B4 B6 : 0.7 kg CO2 eq.
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP20 IEC 60529 rear face), IP20 IEC 60529 rear face), IP20 IEC 60529 rear face), IP65 IEC 60529 front face), IP65 IEC 60529 front face), IP65 IEC 60529 front face)
    • Nema Degree Of Protection : NEMA 4 UL 50 E, NEMA 4 UL 50 E, NEMA 12 UL 50 E, NEMA 12 UL 50 E
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 1.1451833082
    • Circularity Profile : ENVEOLI2312030EN
    • Environmental Disclosure : ENVPEP2312030EN
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2312030EN
    • Pep Verification Date : 2023-12-07
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : pilot light
    • Range Of Product : Harmony XB7
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Overview Attributes
    • Device Presentation : monolithic product