Enercept Meter, class 0.2S, Modbus/BACnet RS485, Rogowski 12", ANSI wire code

SYS MTR,12ROG,FDS,MB/BAC,3PH4W

SQDMETSEEM4236A12 METSEEM4236A12 SQDMETSEEM4236A12
1502.67 / EA
http://schema.org/OutOfStock
  • Depth: 35.81 mm
  • Number of Outputs: 0
The PowerLogic EM4200 Series Enercept power and energy meter is a unique compact retrofit solution for measuring energy data. This bundle ships with 3, 12 inch Rogowski current transformers rated up to 5,000 A. Accuracy calibrated at 1%. ANSI version, fuse packs factory mounted. Designed for simplicity, the EM4200 has flexibility of a wide range of Current Transducers to match most applications from 50-5000A. This billing-rated, four-quadrant meter offers BACnet and Modbus communication protocols and supply power options from 90-480VAC. ANSI C12.1 rated and UL 61010-1.
QTY
  • Product Description
  • Features
  • Specifications
The PowerLogic EM4200 Series Enercept power and energy meter is a unique compact retrofit solution for measuring energy data. This bundle ships with 3, 12 inch Rogowski current transformers rated up to 5,000 A. Accuracy calibrated at 1%. ANSI version, fuse packs factory mounted. Designed for simplicity, the EM4200 has flexibility of a wide range of Current Transducers to match most applications from 50-5000A. This billing-rated, four-quadrant meter offers BACnet and Modbus communication protocols and supply power options from 90-480VAC. ANSI C12.1 rated and UL 61010-1.
  • Features
    • Wide range of service types compatible
    • Modbus and BACnet protocols sets in one unit
    • Flexibility for retrofit applications
    • DIN rail or screw mount options
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU 9600 bauds...115200 bauds (automatic detection), BACnet MS/TP 9600 bauds...115200 bauds (automatic detection)
    • Communication Of Data : remote control orders, total energy, net energy
  • Physical Attributes
    • Wire Stripping Length : 6 mm
  • Conformance Attributes
    • Product Certifications : CE conforming to EN 61010-1, cULus conforming to UL 61010-1, BTL, IEC
    • Standards : EN 61010-1, UL 61010-1, CAN/CSA C22.2 No. 61010-1-12
  • Important Information Attributes
    • Electromagnetic Compatibility : immunity to radiated fields conforming to EN 61326-1, conducted and radiated emissions conforming to FCC Part 15 class A, conducted and radiated emissions conforming to EN 61000-6-4, conducted and radiated emissions conforming to EN 61326 + A1, immunity to conducted disturbances conforming to EN 61000-6-2, immunity to conducted disturbances conforming to EN 61326-1, immunity to radiated fields conforming to EN 61000-6-2
    • Function Available : external synchronisation to communication, fixed or rolling block
    • Local Signalling : status LED green and red), line fault 3 LED green, orange and red), dial pointer indication LED Yellow), RX/TX 2 LED green, orange and red)
    • Measurement Voltage : 90-90 V AC 45...65 Hz minimum per phase, 480-480 V AC 45...65 Hz between phases, 300-300 V AC 45...65 Hz between phase and neutral
    • Mounting Mode : by screws, clip-on, by hook
    • Mounting Support : enclosure, DIN rail
    • Network Frequency : 50 Hz, 60 Hz
    • Provided Equipment : bracket for support, hook, Rogowski coil 3 12 in, fuse
    • Carbon Footprint Of The Distribution Phase A4 : 0.40720952696369933, 0.4 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 2 kg CO2 eq., 2.0161844847648314
    • Carbon Footprint Of The Installation Phase A5 : 0.029608367184446163, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 38 kg CO2 eq., 38.40741506477476
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 57 kg CO2 eq., 57.29884402739639
    • Connections Terminals : input/output plug-in connector bottom) 0.2-1.5 mm², current transformer plug-in connector bottom) 0.2-1.5 mm², communication plug-in connector bottom) 0.2-1.5 mm²
    • Measurement Category : category III 277-277 V, category III 300-300 V
    • Metering Type : active, reactive, apparent energy (signed, four quadrant), apparent power S, S1, S2, S3, demand power P, Q, S, active power P, P1, P2, P3, reactive power Q, Q1, Q2, Q3, power factor, average current Iavg, peak demand power PM, QM, SM, frequency, voltage U21, U32, U13, V1, V2, V3
    • Connections Terminals3 : input/output plug-in connector bottom) 0.2-1.5 mm², current transformer plug-in connector bottom) 0.2-1.5 mm², communication plug-in connector bottom) 0.2-1.5 mm²
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Manufacturer : Schneider Electric
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2506060EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Device Application : power monitoring
    • Device Short Name : Enercept
    • Display Type : Without Display
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 45-65 Hz
    • Measurement Accuracy : 1 %
    • Measurement Current : 50-5000 A
    • Package Weight Lbs : 1409.09 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : energy meter
    • Range : PowerLogic
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 98 kg CO2 eq.
    • Type Of Cable : ANSI cable
    • Medium Desc : Enercept Meter, class 0.2S, Modbus/BACnet RS485, Rogowski 12", ANSI wire code
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP2506060EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-10-29
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Form Factor : system calibrated
    • Global Commercial Status : Commercialised
    • Product Name : PowerLogic EM4200
  • Environment Attributes Main
    • Take Back : No, Nej
    • China ROHS Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -15-60 °C, -15-60 °C
    • EU ROHS Directive : Compliant By Exemption , Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 98.15926147108414
    • Ambient Air Temperature For Storage : -40-85 °C
    • Circularity Profile : ENVEOLI2506060EN
    • Environmental Disclosure : ENVPEP2506060EN
    • IP Degree Of Protection : IP20 conforming to IEC 60529
    • Operating Altitude : < 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Relative Humidity : 0-95 %
    • Pep Code : ENVPEP2506060EN
    • Pep Verification Date : 2025-10-29
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Provided Equipment : bracket for support, hook, Rogowski coil 3 12 in, fuse
    • Product Or Component Type : energy meter
  • Output Attributes
    • Number Of Outputs : 0
  • Input Attributes
    • Analogue Input Type : Rogowski coil 0.333 V (impedance 33 kOhm), voltage (impedance 2.5 MOhm)single phase, voltage (impedance 5 MOhm)phase to phase
    • Number Of Inputs : 0
  • Specifications
    • Depth : 35.81 mm