Transformer, dry type, DOE 2016, 300kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 30J, 80C rise, Cu

Transformer, dry type, DOE 2016, 300kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 30J, 80C rise, Cu

SQDEX300T68HBCU EX300T68HBCU 785901003830
45513.70 / EA
http://schema.org/OutOfStock
  • Depth: 963 mm
  • Material: Copper
  • Primary Voltage: 480 V
  • Temperature Rise: 220 °C, 80 °C
EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 300kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 80 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 99.02% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=EX300T68HBCU&p_File_name=EX300T68HBCU.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=EX300T68HBCU&p_File_name=EX300T68HBCU.dxf
  • Conformance Attributes
    • Standards : UL 1561, CSA C22.2 No 47, NEMA ST-20
  • Complementary Attributes
    • Rated Operational Power In Va : 300 kVA
    • Ipk Rated Peak Withstand Current : 29.3 kA
    • Uimp Rated Impulse Withstand Voltage : 10 kV
  • Important Information Attributes
    • Continuous Thermal Current Rating Factor : 2423.329890404736 16.6 %, 2610.28863 25 %, 3613.458378 50 %, 5285.407958 75 %, 7626.1373699999995 100 %
    • Electrical Connection : 4 Hole Nema Pad primary 11.1 mm, 6 Hole Nema Pad secondary 11.1 mm, 8 Hole Nema Pad sec - XO 11.1 mm
    • Mounting Support : floor, floor, with 7400FMB
    • Noise Level : 55 dB, 0 dB
    • Number Of Tap Offs : 2 2.5 % FCAN, 2 2.5 % FCBN
    • Tap Loss : 667.0 no load (core loss), 1568.0 load loss (coil loss)
    • Temperature Rise : 80 °C, 220 °C insulated
    • Carbon Footprint Of The Distribution Phase A4 : 317.0814050244196, 317 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 4 038 kg CO2 eq., 4038.2150948472013
    • Carbon Footprint Of The Installation Phase A5 : 83.42474937124832, 83 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 7 941 kg CO2 eq., 7941.4928772979065
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 62 922 kg CO2 eq., 62922.35056175125
    • Medium Desc : Transformer, dry type, DOE 2016, 300kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 30J, 80C rise, Cu
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : Transformer - dry
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : PSIBS
    • Average Life Duration : 25 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Box Number : 30J
    • Device Application : low voltage electrical distribution
    • Device Short Name : DOE 2016
    • Efficiency : 99.20 % at 35 % load factor , 75.0 °C
    • Material : copper
    • Network Frequency : 60 Hz
    • Percentage Impedance Voltage : 2.8 %
    • Percentage Reactance : 0.0279 %
    • Phase : 3 phase
    • Primary Voltage : 480 V delta
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : transformer
    • Range Of Product : Square D
    • Returnability : No
    • Secondary Voltage : 208Y/120 V
    • Software Version : v6.2.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 75 303 kg CO2 eq.
    • Transformer Type : energy efficient
    • Type Of Cooling : natural convection
    • Ipk Rated Peak Withstand Current : 29.3 kA
    • Pep Code : ENVPEP1604027EN
    • Database Version : 2024-11
    • Pep Verification Date : 2025-02-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Data Source : extrapolated product
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.To step down a distribution line voltage of 75kVA to voltage levels used by the end customer at the energy efficiency requirements defined by the DOE for 20 years.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model Installation A5 2 : Electricity origin
    • Energy Model Use B6 2 : Electricity origin
    • Energy Model End Of Life C1 C4 2 : Electricity origin
    • Height Nominal : 1803 mm
    • Width Nominal : 1226 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 75302.56468829203
    • Ambient Air Temperature For Operation : 40-40 °C
    • Average Ambient Air Temperature For Operation : 30 °C
    • Environmental Disclosure : ENVPEP1604027EN
    • Eu Rohs Directive : Compliant
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1604027EN
    • Pep Verification Date : 2025-02-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : transformer
    • Range Of Product : Square D
  • Input Attributes
    • Efficiency : 99.20 % at 35 % load factor , 75.0 °C
  • Specifications
    • Depth : 963 mm