SQUARE D

Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, shunt, ABC

Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, shunt, ABC

SQDHGA36100SA HGA36100SA 785901840787
2379.54 / EACH
http://schema.org/OutOfStock
  • Color: Black
  • Depth: 86 mm
  • Warranty Length: 18 mth
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Features
    • Available in 2 or 3 pole design
    • Standard 80% or 100% rating
    • Available in Unit mount, I-line or Drawout constructions
    • A wide range of accessories, auxiliaries, and lug connections available
    • UL 489 Listed, CSA, NEMA, NMX, VDE, BS, CCC, IEC certified, and CE marked
  • Communications & Management Attributes
    • Communication Interface : Modbus, Ethernet
  • Physical Attributes
    • Color : Black
    • Wire Stripping Length : 16 mm
  • Conformance Attributes
    • Product Certifications : UL, CSA, NOM
    • Standards : UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2
  • Complementary Attributes
    • Line Rated Current : 100-100 A
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electrical Connection : I-Line connection, line, lugs, load
    • Number Of Slots : 2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in), 1 overcurrent trip switch SDE plug-in), 1 voltage release MN or MX plug-in)
    • Tightening Torque : 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10), 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
    • Ics Rated Service Breaking Capacity2 : 65 kA 220/240 V AC 50/60 Hz IEC 60947-2, 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 18 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2
    • Carbon Footprint Of The Distribution Phase A4 : 0.47671962660306033, 0.5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 4 kg CO2 eq., 4.240897358179155
    • Carbon Footprint Of The Installation Phase A5 : 0.022843241036541097, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 12 kg CO2 eq., 11.541596209033251
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 228 kg CO2 eq., 227.75998885676907
    • Ics Rated Service Breaking Capacity5 : 65 kA 220/240 V AC 50/60 Hz IEC 60947-2, 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 18 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2206027_V2
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • Function Option Id : STANDARD
    • Function Option : Standard
    • AWG Gauge : AWG 14...AWG 3/0 aluminium/copper terminal
    • Circuit Breaker Application : HACR rated
    • Continuous Current Rating : 80 %
    • Control Type : toggle
    • Device Application : distribution
    • Energy Efficiency Optimized : False
    • Local Signalling : switched off (OFF) 1 trip indicator green)
    • Magnetic Hold Current : 900 A
    • Magnetic Tripping Current : 1700-1700 A
    • Mounting Mode : I-Line bracket)
    • Mounting Support : bracket
    • Network Frequency : 50/60 Hz
    • Package Weight Lbs : 2.268 kg
    • Phase Connection : ABC
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : circuit breaker
    • Protected Poles Description : 3t
    • Quality Labels : CE
    • Range : PowerPact
    • Returnability : No
    • Suitability For Isolation : yes IEC 60947-2
    • Sustainable Packaging : No
    • Terminal Identifier : AL150HD
    • Total Lifecycle Carbon Footprint : 244 kg CO2 eq.
    • Trip Unit Technology : thermal-magnetic
    • Utilisation Category : category A
    • Ue Rated Operational Voltage2 : 690 V AC 50/60 Hz IEC 60947-3
    • Ui Rated Insulation Voltage2 : 750 V IEC 60947-2
    • Uimp Rated Impulse Withstand Voltage2 : 8 kV IEC 60947-2
    • Accessory Separate Part Type2 : shunt trip 110...130 V AC compartment
    • Medium Desc : Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, shunt, ABC
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP2206027EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-05-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icu, and, if applicable, the specific specifications, in the Industrial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Global Commercial Status : Commercialised
    • Product Name : PowerPact H
    • Accessory Separate Part Type3 : shunt trip 110...130 V AC compartment
    • Ue Rated Operational Voltage5 : 690 V AC 50/60 Hz IEC 60947-3
    • Ui Rated Insulation Voltage5 : 750 V IEC 60947-2
    • Uimp Rated Impulse Withstand Voltage5 : 8 kV IEC 60947-2
  • Environment Attributes Main
    • Take Back : No, Nej
    • EU ROHS Directive : Compliant By Exemption , Compliant with Exemptions
    • Operating Altitude : < 6561.68 ft (2000 m) without derating, < 6561.68 ft (2000 m) without derating, < 6561.68 ft (2000 m) without derating, < 6561.68 ft (2000 m) without derating, 5000 m with derating
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 244.0420452916211
    • Ambient Air Temperature For Operation : -25-70 °C
    • Ambient Air Temperature For Storage : -50-85 °C
    • Circularity Profile : ENVEOLI2206027_V2
    • Environmental Disclosure : ENVPEP2206027EN
    • IP Degree Of Protection : front cover IP40 IEC 60529
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2206027EN
    • Pep Verification Date : 2025-05-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : circuit breaker
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 86 mm
  • Batteries & Runtime Attributes
    • Removable Battery : No