Circuit breaker, PowerPacT H, 40A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, AC

600V 40AMP 2POLE HDA BREAKER

SQDHDA260402 HDA260402 785901632498
1349.16 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, NOM, UL
  • Depth: 86 mm
  • Height: 163 mm
  • Line Rated Current: 40-40 A
  • Mounting Type: I-Line Bracket)
  • Net Weight: 2.2 kg
  • Standard: CSA, IEC 60947-2, NEMA, NOM-003-SCFI-2000, UL
  • Storage Temperature: -50-85 °C
  • Strip Length: 16 mm
  • Trip Point: 850-850 A
  • Warranty Length: 18 mth
  • Width: 104 mm
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 40A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
QTY
  • Product Description
  • Specifications
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 40A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
  • Environment
    • Ambient Air Temperature For Operation : -25-70 °C
    • Standards : UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
    • Product Certifications : UL || CSA || NOM
    • Ip Degree Of Protection : front cover IP40 IEC 60529
    • Pollution Degree : 3 IEC 60947-1
    • Ambient Air Temperature For Storage : -50-85 °C
    • Quality Labels : CE
    • Operating Altitude : < 6561.68 ft (2000 m) without derating || 5000 m with derating
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2206027EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : ENVEOLI2206027EN
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Mounting Mode : I-Line bracket)
    • Network Frequency : 50/60 Hz
    • Terminal Identifier : AL150HD
    • [Ics] Rated Service Breaking Capacity : 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
    • Trip Unit Technology : thermal-magnetic
    • Height : 163 mm
    • [Ue] Rated Operational Voltage : 690 V AC 50/60 Hz IEC 60947-3
    • Tightening Torque : 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
    • Mounting Support : bracket
    • Breaking Capacity Code : D
    • Magnetic Tripping Current : 850-850 A
    • Local Signalling : switched off (OFF) 1 trip indicator green)
    • Protected Poles Description : 2t
    • Number Of Slots : 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
    • Electrical Connection : I-Line connection, line || lugs, load
    • Mounting Height : 3 in
    • Net Weight : 2.2 kg
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • Magnetic Hold Current : 400 A
    • Control Type : toggle
    • Circuit Breaker Application : HACR rated
    • Wire Stripping Length : 16 mm
    • Line Rated Current : 40-40 A
    • Utilisation Category : category A
    • Continuous Current Rating : 80 %
    • Breaking Capacity : 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
    • [Ui] Rated Insulation Voltage : 750 V IEC 60947-2
    • Suitability For Isolation : yes IEC 60947-2
    • Communication Interface : Modbus || Ethernet
    • Poles Description : 2P
    • Quantity Per Set : 1
    • Awg Gauge : AWG 14...AWG 3/0 aluminium/copper terminal
    • Color : Black
    • Width : 104 mm
    • Depth : 86 mm
    • Phase Connection : AC
  • Specifications
    • Product Or Component Type : circuit breaker
    • Product Name : PowerPact H
    • Range : PowerPact
    • Device Application : distribution