universal protection relay, PowerLogic P3U 3CT 1Io 14DI 11DO 48-230V DI110 RS485 RL

UNIVERSAL PROTECTION RELAY, PO

SQDREL53152 REL53152 3606487107019
3683.57 / EA
http://schema.org/OutOfStock
  • Country of Origin: Latvia
  • Depth: 205 mm
  • Display Type: LCD 128 X 64 Pixels With Single Line Diagram
  • Height: 169.5 mm
  • Net Weight: 2.5 kg
  • Number of Outputs: 1 Watchdog, 11 DO
  • Warranty Length: 10 yr, 2 yr
  • Width: 170 mm
Perfectly suited for buildings and industry, utilities, and large industrial processes. This relay is configurable to Feeder and Motor Protection applications. The relay include protection for overcurrent, overload, broken conductor, earth-fault and breaker failure as per ANSI. It also feature an automatic recloser, a switch ON to fault, inrush protection and lockout among others. Simple, reliable, safe and easy-to-use, thanks to the User Interface display. The protection relay can to be supplied by a 48 VAC/VDC to 230 VAC/VDC network. It include 14 digital inputs, 11 digital outputs, 1 RS485 communication port and 1 USB on front of the device. Mechanical dimensions are 169.5 mm in height, 170 mm in width and 205 mm in depth. The relays are certified with EN 60255-26 for electromagnetic compatiblity. The device is compatible with aditional modules and accessories: connection cables, communication modules, temperature and analogue input and output modules, and other accessories. This device has pluggable ring-lug terminals for current inputs.
QTY
  • Product Description
  • Specifications
Perfectly suited for buildings and industry, utilities, and large industrial processes. This relay is configurable to Feeder and Motor Protection applications. The relay include protection for overcurrent, overload, broken conductor, earth-fault and breaker failure as per ANSI. It also feature an automatic recloser, a switch ON to fault, inrush protection and lockout among others. Simple, reliable, safe and easy-to-use, thanks to the User Interface display. The protection relay can to be supplied by a 48 VAC/VDC to 230 VAC/VDC network. It include 14 digital inputs, 11 digital outputs, 1 RS485 communication port and 1 USB on front of the device. Mechanical dimensions are 169.5 mm in height, 170 mm in width and 205 mm in depth. The relays are certified with EN 60255-26 for electromagnetic compatiblity. The device is compatible with aditional modules and accessories: connection cables, communication modules, temperature and analogue input and output modules, and other accessories. This device has pluggable ring-lug terminals for current inputs.
  • Environment
    • Mechanical Robustness : vibrations class II) IEC 60255-21-1 || vibrationsFc IEC 60068-2-6 || shocks class II) IEC 60255-21-2 || shocksEa IEC 60068-2-27 || seismic tests method A class II) IEC 60255-21-3
    • Ambient Air Temperature For Operation : -40-65 °C
    • Environmental Characteristic : exposure to dry heat Bb EN/IEC 60068-2-2 || exposure to cold Ad EN/IEC 60068-2-1 || exposure to damp heat in service Db EN/IEC 60068-2-30 || exposure to damp heat in service Cab EN/IEC 60068-2-78
    • Ip Degree Of Protection : IP54 front IEC 60529
    • Electromagnetic Compatibility : emission tests IEC/EN 60255-26 ed. 3 || emission tests class A CISPR 11 || emission tests class A CISPR 22 || EMC immunity IEC/EN 60255-26 ed. 3 || EMC immunity EN/IEC 61000-4-18 || EMC immunity level 4 EN/IEC 61000-4-2 || EMC immunity level 3 EN/IEC 61000-4-3 || EMC immunity level 4 EN/IEC 61000-4-4 || EMC immunity level 3 EN/IEC 61000-4-5 || EMC immunity level 3 EN/IEC 61000-4-6 || EMC immunity EN/IEC 61000-4-8 || EMC immunity level 5 EN/IEC 61000-4-9 || EMC immunity EN/IEC 61000-4-29 || EMC immunity EN/IEC 61000-4-11 || EMC immunity EN/IEC 61000-4-17
    • Relative Humidity : 0-95 %, without condensation
    • Protective Treatment : conformal coating
    • Operating Altitude : 6561.68 ft (2000 m)
  • Contractual warranty
    • Warranty : up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP1706006_V2
    • Packaging Without Single Use Plastic : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : 7fd15df9-a702-4a28-ad01-afb36a7b785f
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Circularity Profile : ENVEOLI1706006_V2
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 623.8010019422173
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 83.6326797890491
    • Carbon Footprint Of The Distribution Phase [A4] : 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0.1 kg CO2 eq.
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 718 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 6.898793401946143
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 717.9023406918308
  • Complementary
    • Number Of Key : 2 customizable
    • Local Signalling : 4 LEDs || 8 LEDs programmable
    • Depth : 205 mm
    • Operating Threshold : 24 V AC/DC
    • Time Synchronisation Protocol : SNTP
    • Width : 170 mm
    • Height : 169.5 mm
    • Display Type : LCD 128 x 64 pixels with single line diagram
    • Net Weight : 2.5 kg maximum
    • Software Name : eSetup Easergy Pro virtual simulation test || Easergy SmartApp
    • Web Server : embedded HTTP server
  • Specifications
    • Country of Origin : Latvia
    • Analogue Output Number : 0
    • Input Type : 3 1/5 A CT phase current || 1 1/5 A CT residual current || 4 100 V/110 V VT voltage
    • Range Of Product : PowerLogic P3
    • Connections - Terminals : screw removable (digital input/output) || pin removable (voltage transformer) || pin removable (current transformer)
    • Network And Machine Diagnosis Type : event recording || disturbance recording || tripping context
    • Device Mounting : flush
    • Number Of Outputs : 11 DO || 1 watchdog
    • Protection Type : phase overcurrent 50/51 || directional phase overcurrent 67 || earth fault overcurrent 50N/51N || broken conductor 46 I2/I1 || cold load pick-up 68H2 || switch ON to fault (SOTF) 50/51 || programmable curve 99 8-8 || transient earth fault 67NI || cold load pick-up || directional earth fault 67N || capacitor bank unbalance 51C || H2 detection 68H2 || H5 detection 68H5 || breaker failure 50BF || switch ON to fault (SOTF) || directional active underpower 37P || fault locator 21FL || recloser 79 || phase undercurrent 37 || excessive starting time, locked rotor 48/51LR || motor restart inhibition 66 || capacitor overvoltage 59C || negative sequence overcurrent 46 || overvoltage 59 || undervoltage 27 || positive sequence undervoltage 27P || earth fault overvoltage 59N || underfrequency 81/81N || rate of change of frequency 81R || synchro-check 25 || lockout relay 86 || CT supervision 60 || VT supervision 60 || programmable stages 99 8-8
    • Relay Application : universal
    • Communication Port Protocol : IEC 60870-5-101 || IEC 60870-5-103 || DNP3 || Modbus RTU || DeviceNet || SPAbus
    • Product Or Component Type : protection relay
    • Single Line Diagram : 4 controlled + 8 displayed
    • Mounting Case Size : 30TE
    • Monitoring Function : trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring
    • Analogue Input Number : 0
    • Mounting Mode : flush mounting
    • Control Type : switchgear control and monitoring || programmable switchgear interlocking || local control on single-line diagram || local control with I/O keys || local/remote control || 2 function keys || mobile application with Easergy SmartApp || web-server || programmable logic
    • Digital Input Number : 14
    • Setting : 4
    • Integrated Connection Type : front USB port 1 || rear RS485 1
    • Cybersecurity : password protection || port hardening
    • Switchgear Diagnosis Type : CT supervision TCS || trip circuit supervision TCS
    • Arc Flash Protection : no
    • Type Of Measurement : voltage phase to earth || frequency phasor diagram view || active power 2nd, 15th harmonics with THD || RMS active power 3-phase || reactive power zero sequence || RMS reactive power positive sequence || apparent power negative sequence || RMS apparent power ratio of negative and positive || active energy phase to earth || reactive energy zero sequence || cos φ positive sequence || tan φ ratio of negative and positive || short circuit fault reactance || current 3-phase || fault location current || active power || current zero sequence || voltage positive sequence || voltage ratio of negative and positive || earth fault reactance || frequency || current positive sequence || current negative sequence || current ratio of negative and positive || voltage phase to phase || voltage zero sequence || voltage negative sequence || RMS active power || reactive power || RMS reactive power || apparent power || RMS apparent power || active energy || reactive energy || cos φ || tan φ || power angle || power factor || voltage phasor diagram view || current phasor diagram view || current 2nd, 15th harmonics with THD || voltage 2nd, 15th harmonics with THD || condition monitoring CB wear || voltage interruption
    • Device Short Name : P3U30-6AAA2BGAB
    • [Us] Rated Supply Voltage : 24...48 V AC/DC