Surge protective device, Surelogic, MA replacement module, 100kA, 600V delta, 3 phase, 3 wire, open style

Surge protective device, Surel

SQDMAM91 MAM91 047569001819
955.45 / EA
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Depth: 13.462 cm
  • Nominal Discharge Current: 20 kA
Surgelogic™ Type MA Systems feature module assemblies designed to ensure continued compliance with safety standards and optimal performance specifications following surge events. This is used as a replacement module for Surgelogic™ IMA and EMA Surge Protective Devices, it ensures continued protection and performance. Being modular in design, this unit is able to provide a surge current rating of 100,000 Amps and 120,000 Amps in severe electrical conditions through immediate responses from its advance diagnostic system. Designed for 600VAC delta three phase systems. This product is UL and CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
Surgelogic™ Type MA Systems feature module assemblies designed to ensure continued compliance with safety standards and optimal performance specifications following surge events. This is used as a replacement module for Surgelogic™ IMA and EMA Surge Protective Devices, it ensures continued protection and performance. Being modular in design, this unit is able to provide a surge current rating of 100,000 Amps and 120,000 Amps in severe electrical conditions through immediate responses from its advance diagnostic system. Designed for 600VAC delta three phase systems. This product is UL and CSA certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Uc Maximum Continuous Operating Voltage : 420 V, 700 V
    • Ue Rated Operational Voltage : 600 V delta AC
  • Important Information Attributes
    • Device Short Name : IMA, EMA
    • Local Signalling : status LED green per phase normal operation, status LED red per phase fault
    • Noise Level : -42 dB, -42 dB
    • Carbon Footprint Of The Distribution Phase A4 : 0.1170229142, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.9 kg CO2 eq., 0.9205778443
    • Carbon Footprint Of The Installation Phase A5 : 0.0030894122, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 13 kg CO2 eq., 12.8658221557
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 1 651 kg CO2 eq., 1651
    • Certificate Agency : UL 1449:ed. 5, CSA C22.2 No 269.1
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-12-12
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Use Carbon Footprint : 1651
    • Weee Scope : In
    • Weee Product Category : 4
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2002011EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2531
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 47-63 Hz
    • Nominal Discharge Current : 20 kA
    • Phase : 3 phase
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : surge protection module
    • Range Of Product : Surgelogic
    • Returnability : Yes
    • Short Circuit Protection : 200 kA
    • Software Version : EIME v5.8.1
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 1 665 kg CO2 eq.
    • Wiring Configuration : 3-wire
    • Accessory Separate Part Category : replacement accessories
    • Connections Terminals : terminals AWG 10...AWG 2
    • Warranty In Months : 18
    • Database Version : 2016-11
    • Pep Verification Date : 2020-04-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Protect during 20 years against direct or indirect effects of lightning or against transient overvoltages electrical equipements connected to electrical networks with a rated operational voltage is 3 phases,160 kA per phase. 480 V delta AC& 10-UL 1449:ed. 4 and UL 1283:ed. 5& 10-CSA C22.2 No 8:1986& 10-ANSI/IEEE C62.41 and ANSI/IEEE C62.45& 10-NEC 285
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unité (unit)
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 2384.472
    • Energy Model - Manufacturing [A1-a3] : Energy model used: MEXICO
    • Energy Model - Installation [A5] : Electricity mix; AC; 120V; US
    • Energy Model - Use [B6] : Electricity mix; AC; 120V; US
    • Energy Model - End Of Life [C1-c4] : Electricity mix; AC; 120V; US
    • Height Nominal : 20.828 cm
    • Width Nominal : 14.734 cm
    • Acidification Of Soil And Water (Kg.Equivalent.So2) Operational Energy Use [B6] : 1.5807
    • Air Pollution (M3) Operational Energy Use [B6] : 140210
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 20101
    • Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6] : 1651
    • Hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 44.142
    • Net Use Of Fresh Water (M3) Operational Energy Use [B6] : 2.9179
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 252.44
    • Photochemical Ozone Formation (Kg.Equivalent.C2h4) Operational Energy Use [B6] : 0.2532
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 20891
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 22226
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 1334.8
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 20891
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1334.8
    • Water Pollution (M3) Operational Energy Use [B6] : 81393
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-60 °C, -20-60 °C
    • Ambient Air Temperature For Storage : -40-65 °C, -40-65 °C
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 1664.9065123263
    • Circularity Profile : ENVEOLI2002011EN
    • Eu Rohs Directive : Compliant By Exemption
    • Nema Degree Of Protection : open type
    • Operating Altitude : 0...12000 ft
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 0-95 %
    • Pep Verification Date : 2020-04-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : surge protection module
    • Range Of Product : Surgelogic
  • Surge Protection And Filtering Attributes
    • Surge Current : 100 kA
  • Specifications
    • Country of Origin : Mexico
    • Depth : 13.462 cm