Surge protection device, Surgelogic, HL, 240kA, 480Y/277VAC, 3 phase, 4 wire, SPD type 2

SPD T2 HL I-LINE 240KA 480Y/27

SQDHL4IMA24C HL4IMA24C 785901948995
17045.48 / EACH
http://schema.org/OutOfStock
  • Cable Length: 483 mm
  • Country of Origin: Mexico
  • Depth: 142.1 mm
  • Height: 308.9 mm
  • Length: 483 mm
  • Number of Poles: 3
  • Warranty Length: 18 mth
  • Width: 341.9 mm
Surgelogic™ internally mounted surge protection devices delivers specification grade performance for service entrance or critical branch I-Line panel applications. These multiphase systems provide suppression, enchanced EFI/RFI filtering for all critical modes inside electrical equipment, and shorter lead lengths with superior SPD performance. They provide better performance with a diagnostic interface with push to test diagnostic switches, red and green status LEDs, module status LEDs per mode, dry contacts, audible alarm with disable switch, and a surge counter. These products have a 10 year product warranty and 10 modes of protection. This surge protection device is 3 phase, 4-wire + ground, 480Y/277 V, 50 kA breaking capacity, 240 kA surge current, and short circuit current rating of 200 kA. The device is engineered to UL 489 11th Edition, type 2 SPD and complies with UL 96A 12th Edition Master Label for Lightning Protection Systems.
QTY
  • Product Description
  • Features
  • Specifications
Surgelogic™ internally mounted surge protection devices delivers specification grade performance for service entrance or critical branch I-Line panel applications. These multiphase systems provide suppression, enchanced EFI/RFI filtering for all critical modes inside electrical equipment, and shorter lead lengths with superior SPD performance. They provide better performance with a diagnostic interface with push to test diagnostic switches, red and green status LEDs, module status LEDs per mode, dry contacts, audible alarm with disable switch, and a surge counter. These products have a 10 year product warranty and 10 modes of protection. This surge protection device is 3 phase, 4-wire + ground, 480Y/277 V, 50 kA breaking capacity, 240 kA surge current, and short circuit current rating of 200 kA. The device is engineered to UL 489 11th Edition, type 2 SPD and complies with UL 96A 12th Edition Master Label for Lightning Protection Systems.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Standards : UL 1449:ed. 3 || UL 1283:ed. 5 || CSA C22.2 No 8:1986 || UL 96A:ed. 12 || UL 489:ed. 11 || CSA C22.2 No 5-09
    • Nema Degree Of Protection : NEMA 2
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Packaging Without Single Use Plastic : No
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Take-Back : No
    • Sustainable Packaging : No
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Height : 308.9 mm
    • Breaking Capacity : 50 kA
    • Connections - Terminals : I-Line line || lugs ground AWG 6 copper 4 N.m || lugs neutral AWG 6 copper 4 N.m
    • Mounting Support : panel mounting
    • Cable Length : 483 mm
    • Provided Equipment : alarm enable/disable switch || surge counter || circuit-breaker
    • Surge Current : 240 kA
    • Phase : 3 phase
    • Local Signalling : status LED green per phase normal operation || status LED red per phase fault
    • Short-Circuit Protection : 200 kA
    • [Uc] Maximum Continuous Operating Voltage : 150 V
    • Line Rated Current : 60 A
    • Width : 341.9 mm
    • Wiring Configuration : 4-wire
    • Depth : 142.1 mm
    • Trip Unit Technology : thermal-magnetic
    • Number Of Poles : 3
    • [Ue] Rated Operational Voltage : 480Y/277 V AC
  • Specifications
    • Country of Origin : Mexico
    • Length : 483 mm
    • Width : 341.9 mm
    • Height : 308.9 mm
    • Range Of Product : Surgelogic
    • Breaking Capacity Code : HL
    • Product Or Component Type : surge protection device
    • Device Short Name : IMA