Surge protection device, Surgelogic, HL, 240kA, 240/120 VAC delta, 3 phase, 4 wire, SPD type 2

SPD T2 HL I-LINE 240KA 240/120

SQDHL3IMA24C HL3IMA24C 785901612841
16359.21 / EACH
http://schema.org/OutOfStock
  • Cable Length: 483 mm
  • Depth: 142.1 mm
  • Height: 308.9 mm
  • Length: 483 mm
  • Number of Poles: 3
  • Warranty Length: 18 mth
  • Width: 341.9 mm
Surgelogic™ Type IMA systems are internal surgical protection devices with a focus on service entrance and critical branch panel surge suppresion. With a surge current rating of 240,000 Amps and enhanced EMI/RFI filtering, this unit is retrofitted to be installed in a wide variety I-Line Branch units. Being modular in design, this unit is able to achieve superior surge suppression on the load side including at the branch panel. This product is UL and CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
Surgelogic™ Type IMA systems are internal surgical protection devices with a focus on service entrance and critical branch panel surge suppresion. With a surge current rating of 240,000 Amps and enhanced EMI/RFI filtering, this unit is retrofitted to be installed in a wide variety I-Line Branch units. Being modular in design, this unit is able to achieve superior surge suppression on the load side including at the branch panel. This product is UL and CSA certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Standards : UL 1449:ed. 3 || UL 1283:ed. 5 || CSA C22.2 No 8:1986 || UL 96A:ed. 12 || UL 489:ed. 11 || CSA C22.2 No 5-09
    • Nema Degree Of Protection : NEMA 2
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Packaging Without Single Use Plastic : No
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Take-Back : No
    • Sustainable Packaging : No
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Height : 308.9 mm
    • Breaking Capacity : 50 kA
    • Connections - Terminals : I-Line line || lugs ground AWG 6 copper 4 N.m || lugs neutral AWG 6 copper 4 N.m
    • Mounting Support : panel mounting
    • Cable Length : 483 mm
    • Provided Equipment : alarm enable/disable switch || surge counter || circuit-breaker
    • Surge Current : 240 kA
    • Phase : 3 phase
    • Local Signalling : status LED green per phase normal operation || status LED red per phase fault
    • Short-Circuit Protection : 200 kA
    • [Uc] Maximum Continuous Operating Voltage : 150 V
    • Line Rated Current : 60 A
    • Width : 341.9 mm
    • Wiring Configuration : 4-wire
    • Depth : 142.1 mm
    • Trip Unit Technology : thermal-magnetic
    • Number Of Poles : 3
    • [Ue] Rated Operational Voltage : 240/120 V delta AC
  • Specifications
    • Length : 483 mm
    • Width : 341.9 mm
    • Height : 308.9 mm
    • Range Of Product : Surgelogic
    • Breaking Capacity Code : HL
    • Product Or Component Type : surge protection device
    • Device Short Name : IMA