Surge protection device, Surgelogic, EMA, 160kA, 480Y/277VAC, 3 phase, 4 wire, NEMA 1

Surge protection device, Surgelogic, EMA, 160kA, 480Y/277VAC, 3 phase, 4 wire, NEMA 1

SQDSSP04EMA16 SSP04EMA16 785901988984
3503.00 / EA
http://schema.org/OutOfStock
  • Cable Length: 483 mm
  • Depth: 135 mm
  • Enclosure Material: Sheet Steel
  • Height: 282 mm
  • Mounting Type: Surface
  • Number of Phases: 3
  • Standard: CSA C22.2 No 8, UL 1283:ed. 5, UL 1449:ed. 4
  • Width: 253.5 mm
Surgelogic™ Type EMA Series surge protective devices deliver specification grade performance for service entrance or critical branch panel applications. These multi-phase surge suppression systems provide transient suppression, noise filtration, enhanced EMI/RFI filtering with sine wave tracking in a durable modular package. They provide better performance with a diagnostic interface with push to test switches, red and green status LEDs, module status LEDs per mode, dry contacts, audible alarm with disable switch, and a surge counter. This surge protection device is 3 phase, 4-wire + ground, 240/120 V, 160 kA surge current per phase, and short circuit current rating of 200 kA. It has 10 year product warranty and 15 modes of protection.
QTY
  • Product Description
  • Specifications
Surgelogic™ Type EMA Series surge protective devices deliver specification grade performance for service entrance or critical branch panel applications. These multi-phase surge suppression systems provide transient suppression, noise filtration, enhanced EMI/RFI filtering with sine wave tracking in a durable modular package. They provide better performance with a diagnostic interface with push to test switches, red and green status LEDs, module status LEDs per mode, dry contacts, audible alarm with disable switch, and a surge counter. This surge protection device is 3 phase, 4-wire + ground, 240/120 V, 160 kA surge current per phase, and short circuit current rating of 200 kA. It has 10 year product warranty and 15 modes of protection.
  • Complementary
    • Height : 282 mm
    • Connections - Terminals : lugs AWG 10...AWG 2 copper 4 N.m
    • Cable Length : 483 mm
    • Provided Equipment : alarm enable/disable switch || surge counter || dry contacts
    • Surge Current : 160 kA
    • Nominal Discharge Current : 20 kA
    • Phase : 3 phase
    • Local Signalling : status LED green per phase normal operation || status LED red per phase fault
    • Short-Circuit Protection : 200 kA
    • [Uc] Maximum Continuous Operating Voltage : 320 V
    • Width : 253.5 mm
    • Wiring Configuration : 4-wire
    • Depth : 135 mm
    • [Ue] Rated Operational Voltage : 480Y/277 V AC
    • Device Mounting : surface
  • Specifications
    • Range Of Product : Surgelogic
    • Product Or Component Type : surge protection device
    • Device Short Name : EMA
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Eu Rohs Directive : Compliant with Exemptions
  • Environment
    • Ambient Air Temperature For Operation : 65-65 °C
    • Standards : CSA C22.2 No 8 || UL 1449:ed. 4 || UL 1283:ed. 5
    • Nema Degree Of Protection : NEMA 1
    • Enclosure Material : Gray painted sheet steel