SQUARE D

Surge protection device, Surgelogic, 160kA, 120/240 VAC, 1 phase, 3 wire, NEMA 1, disconnect switch

SPD T1 EMA 160KA 120/240V IS 1

SQDSSP01EMA16D SSP01EMA16D 785901075257
1673.33 / EA
http://schema.org/OutOfStock
  • Cable Length: 483 mm
  • Depth: 135 mm
  • Enclosure Material: Gray Painted Sheet Steel
  • Height: 495 mm
  • Length: 483 mm
  • Line Rated Current: 150 A
  • Mounting Type: Surface
  • Number of Phases: 1
  • Number of Poles: 3
  • Standard: CSA C22.2 No 8, UL 1283:ed. 5, UL 1449:ed. 4
  • Width: 251 mm
Surgelogic™ Type EMA systems are external surgical protection devices with a focus on individual phase modules. With a surge current rating of 160,000 Amps, enhanced EMI/RFI filtering of -54 dB at 100 kHz is possible to increase performance at distribution and branch panel applications. Being modular in design, this unit is able to achieve superior surge suppression at every level of the electrical distribution system. This unit provides surge suppression from service entrance panels to point-of-use equipment. This product is UL and CSA certified.
QTY
  • Product Description
  • Specifications
Surgelogic™ Type EMA systems are external surgical protection devices with a focus on individual phase modules. With a surge current rating of 160,000 Amps, enhanced EMI/RFI filtering of -54 dB at 100 kHz is possible to increase performance at distribution and branch panel applications. Being modular in design, this unit is able to achieve superior surge suppression at every level of the electrical distribution system. This unit provides surge suppression from service entrance panels to point-of-use equipment. This product is UL and CSA certified.
  • Complementary
    • Height : 495 mm
    • Local Signalling : status LED green per phase normal operation || status LED red per phase fault
    • Connections - Terminals : lugs AWG 10...AWG 3/0 copper 4 N.m
    • Short-Circuit Protection : 200 kA
    • Cable Length : 483 mm
    • Provided Equipment : alarm enable/disable switch || switch-disconnector || surge counter || dry contacts
    • [Uc] Maximum Continuous Operating Voltage : 150 V
    • Line Rated Current : 150 A
    • Surge Current : 160 kA
    • Wiring Configuration : 3-wire
    • Width : 251 mm
    • Depth : 135 mm
    • Nominal Discharge Current : 20 kA
    • Phase : 1 phase
    • Number Of Poles : 3
    • [Ue] Rated Operational Voltage : 120/240 V AC
    • Device Mounting : surface
  • Environment
    • Ambient Air Temperature For Operation : 65-65 °C
    • Nema Degree Of Protection : NEMA 1
    • Enclosure Material : Gray painted sheet steel
    • Standards : CSA C22.2 No 8 || UL 1449:ed. 4 || UL 1283:ed. 5
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Rohs Exemption Information : Yes
    • Eu Rohs Directive : Compliant with Exemptions
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Specifications
    • Length : 483 mm
    • Width : 251 mm
    • Height : 495 mm
    • Range Of Product : Surgelogic
    • Product Or Component Type : surge protection device
    • Device Short Name : EMA