Fluke 117 Electrician's Multimeter with Non-Contact Voltage Fluke 117

FLUKE 117 DIGITAL MULTIMETER

FLKFLUKE117 FLUKE-117 095969324205
302.26 / Plastic Blister
http://schema.org/OutOfStock
  • Battery Type: 9V Alkaline, NEDA 1604A
  • Display Type: Digital
  • Operating Temperature: -10 To 50 °C
  • Storage Temperature: -40 To 60 °C
  • Warranty Length: 3 yr
  • Weight: 550 g
QTY
  • Features
  • Specifications
  • Key Features
    • Non-contact voltage detection
    • AutoVolt automatic AC/DC voltage selection
    • Prevent false readings caused by ghost voltage with selectable low-impedance mode
  • Product Overview
    • The Fluke 117 Electricians Multimeter includes integrated non-contact voltage detection and Auto Volts and LoZ functions to help get the job done faster and prevent false readings caused by ghost voltage. It is a compact true-rms meter for demanding applications like commercial buildings, hospitals, and schools.
    • The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.
  • Other Useful Features
    • Features true-rms capabilities for accurate measurements on non-linear loads
    • Accurate, easy-to-use multimeter with integrated VoltAlert™ technology for fast, go/no go non-contact voltage detection
    • Features AutoVolt automatic AC/DC voltage selection
    • Provides low input impedance to help prevent false readings due to ghost voltage
    • Presents a large white LED backlight for working in poorly lit areas
    • Measures 10 A (20 A overload for 30-seconds)
    • Measures resistance, continuity, frequency, and capacitance
    • Provides Min/Max/Average to record signal fluctuations
    • Comes with an holster with probe holders for easy storage
    • Fits into optional ToolPak™ magnetic hanger for hands-free operation
    • CAT III 600 V safety rated
    • A large white LED backlight to improve measurement visibility in poorly lit areas
  • Includes
    • 4 mm silicone test lead set
    • Holster
    • User manual
  • Additional Features
    • 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
  • Accuracy Specifications
    • DC millivolts Range/resolution : 600.0 mV / 0.1 mV
    • DC millivolts Accuracy : ±([% of reading] + [counts]): 0.5% + 2
    • DC volts Range/resolution : 6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V
    • DC volts Accuracy : ±([% of reading] + [counts]): 0.5% + 2
    • Auto volts Range/resolution : 600.0 V / 0.1 V
    • Auto volts Accuracy : 2.0% + 3 (DC, 45 Hz to 500 Hz)4.0% + 3 (500 Hz to 1 kHz)
    • AC millivolts¹ True RMS Range/resolution : 600.0 mV / 0.1 mV
    • AC millivolts¹ True RMS Accuracy : 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
    • AC volts¹ True RMS Range/resolution : 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V
    • AC volts¹ True RMS Accuracy : 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
    • Continuity Range/resolution : 600 Ω / 1 Ω
    • Continuity Accuracy : Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer.
    • Ohms Range/resolution : 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ || 40.00 MΩ / 0.01 MΩ
    • Ohms Accuracy : 0.9% + 1 || 5% + 2
    • Diode test Range/resolution : 2.00 V / 0.001 V
    • Diode test Accuracy : 0.9% + 2
    • Capacitance Range/resolution : 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF || > 1000 μF
    • Capacitance Accuracy : 1.9% + 2 || 5% + 20%
    • Lo-Z capacitance Range : 1 nF to 500 μF
    • Lo-Z capacitance Accuracy : 10% + 2 typical
    • AC amps True RMS (45 Hz to 500 Hz) Range/resolution : 6.000 A / 0.001 A10.00 A / 0.01 A
    • AC amps True RMS (45 Hz to 500 Hz) Accuracy : 1.5% + 320 A continuous overload for 30 seconds max
    • DC amps Range/resolution : 6.000 A / 0.001 A   10.00 A / 0.01 A
    • DC amps Accuracy : 1.0% + 320 A continuous overload for 30 seconds max
    • Hz (V or A input)² Range/resolution : 99.99 Hz / 0.01 Hz999.9 Hz / 0.1 Hz9.999 kHz / 0.001 Hz50.00 kHz / 0.01 Hz
    • Hz (V or A input)² Accuracy : 0.1% + 2
  • Mechanical and General Specifications
    • Size : 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    • Weight : 550 g
    • Warranty : 3 years
  • Specifications
    • Maximum voltage between any terminal and earth ground : 600 V
    • Surge protection : 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
    • Fuse for A input : 11 A, 1000 V FAST Fuse (Fluke PN 803293)
    • Display : Digital: 6,000 counts, updates 4 per second
    • Bar graph : 33 segments, updates 32 per second
    • Operating temperature : -10°C to +50°C
    • Storage temperature : -40°C to +60°C
    • Battery type : 9 volt Alkaline, NEDA 1604A / IEC 6LR61
    • Battery life : 400 hours typical, without backlight