SQUARE D

Soft starter, Altivar Soft Starter ATS490, 75A, 208 to 690V AC, control supply 110 to 230V AC

Soft starter, Altivar Soft Sta

SQDATS490D75Y ATS490D75Y 3606486948811
1806.34 / EA
http://schema.org/OutOfStock
  • Connection Type: 1 RJ45 For Connecting Modbus Serial, 1 RJ45 For Connecting Modbus TCP/EtherNet/IP
  • Depth: 234 mm
  • Operating Position: Vertical +/- 10 Degree
This soft starter belongs to the Altivar Soft Starter ATS490 range, which is intended to smoothly start and stop asynchronous motors supplied from 208 to 690V. With an operational rated current of 75A in normal duty, it supplies motor from 15 to 55 kW according to mains voltage. With an efficiency of 99.5%, dedicated application functions, and complete monitoring with data reporting, ATS490 enables advanced motor management. Certified cybersecurity, safe Torque Off, and condition monitoring features increase uptime, reduce operational expenditures, and simplify project design. ATS490 provides comprehensive system monitoring, including the motor, application, power and energy with an accuracy greater than 95%. ATS490 has a native Ethernet port for Modbus TCP or EtherNet/IP and a Modbus serial link. Dimensions are 160mm (width), 234mm (depth), 289mm (height) and it weighs 7kg. ATS490 uses plastic with more than 20% bio-based content, and aluminum is ASI-certified. Altivar Soft Starter ATS490 meets the requirements of applications such as pumps, fans, compressors, conveyors, mixers, cutters, grinders, crushers… It conforms to IEC/EN 60947-4-2 and has received CE, cULus, UKCA, RCM, CCC, and DNV certifications. Some accessories are available, like an IP65 remote mounting kit to mount the graphic display terminal on the enclosure door and communication modules to extend the connectivity to other protocols. The packaging uses recycled cardboard and lower single-use plastic. The ATS490 soft starters shall be mounted vertically inside an enclosure. The built-in and innovative features of ATS490 improve competitiveness, operational resilience, and equipment sustainability. ATS490 delivers excellence in mastering applications and costs, even for the most demanding requirements.
QTY
  • Features
  • Specifications
  • Features
    • Reduced overall cost of solutions (native and innovative functions)
    • Reduced execution time (EcoStruxure solutions)
    • Reduced operational expenditure (high durability)
    • Withstand high stress and avoid limiting event (Increased reliability by design)
    • Simplify project design (certified cybersecurity and safe torque off functions)
    • Reduce carbon footprint (99.5% efficiency and power monitoring)
    • High level of digitization and data reporting for energy and asset management
    • Advanced motor management with a holistic vision
    • Reduced downtime and cost (embedded condition monitoring)
    • The excellence of motor control to master applications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • 3D Model Name : ATS490_S1B1_3D_model
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus serial, Modbus serial, Modbus TCP/EtherNet/IP
  • Conformance Attributes
    • Product Certifications : CE, cULus, UKCA, RCM, CCC, DNV, ATEX, EAC, KC
    • Standards : EN/IEC 60947-4-2, UL 60947-4-2, IEC 60664-1
  • Complementary Attributes
    • Maximum Horse Power Rating : 20 hp 230 V heavy duty, 50 hp 575 V heavy duty, 20 hp 208 V normal duty, 25 hp 230 V normal duty, 50 hp 460 V normal duty, 60 hp 575 V normal duty, 15 hp 208 V heavy duty, 40 hp 460 V heavy duty
    • Maximum Switching Current : relay outputs 2 A / 250 V AC for AC-15 100000 cycles following IEC 60947-5-1, relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1
    • Maximum Permanent Current : 62 A at 40 °C heavy duty
    • Minimum Switching Current : 100 mA 12 V DC relay outputs
    • Integrated Motor Overload Protection : true
  • Important Information Attributes
    • Connector Type : 1 RJ45 for connecting Modbus serial, 1 RJ45 for connecting Modbus TCP/EtherNet/IP
    • Display Type : 1 LED green and yellow)status, 1 LED Red)Warning/Error, 1 LED Yellow)ASF, 1 LED Yellow)COM, 1 LED green and yellow)NET1, 1 LED green and red)NET2, 1 LED green and red)NET3, 1 LED green and yellow)NET4, 1 LED green and red)RUN/ERR (Module Status), 1 LED green and yellow)Ethernet link, 1 LED green and red)ETH MS (Ethernet port configuration status), 1 LED green and red)Eth NS (Ethernet network status)
    • Electromagnetic Compatibility : conducted and radiated emissions level A conforming to IEC 60947-4-2, damped oscillating waves level 3 conforming to IEC 61000-4-18, electrostatic discharge level 3 conforming to IEC 61000-4-2, immunity to electrical transients level 4 conforming to IEC 61000-4-4, immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3, voltage/current impulse level 3 conforming to IEC 61000-4-5, immunity to conducted interference caused by radio-electrical fields level 3 conforming to EN/IEC 61000-4-6
    • Function Available : pre-heating, smoke extraction, second motor set, Deceleration with torque control, Braking, boost, Line contactor control, reverse contactor control, anti-jam, jog, borehole pump starting, condition monitoring, power monitoring, cybersecure firmware update
    • Marking : CE, cULus, UKCA, RCM, CCC, ATEX, EAC, KC
    • Motor Power KW : 30 kW 440 V in the motor supply line heavy duty, 37 kW 500 V in the motor supply line heavy duty, 37 kW 525 V in the motor supply line heavy duty, 45 kW 660 V in the motor supply line heavy duty, 45 kW 690 V in the motor supply line heavy duty, 55 kW 400 V to the motor delta terminals normal duty, 30 kW 230 V to the motor delta terminals heavy duty, 55 kW 400 V to the motor delta terminals heavy duty, 18.5 kW 230 V in the motor supply line normal duty, 37 kW 400 V in the motor supply line normal duty, 37 kW 440 V in the motor supply line normal duty, 45 kW 500 V in the motor supply line normal duty, 45 kW 525 V in the motor supply line normal duty, 55 kW 660 V in the motor supply line normal duty, 55 kW 690 V in the motor supply line normal duty, 15 kW 230 V in the motor supply line heavy duty, 30 kW 400 V in the motor supply line heavy duty, 37 kW 230 V to the motor delta terminals normal duty
    • Option Card : communication module CANopen daisy chain, communication module CANopen Sub-D, communication module CANopen open style, communication module Profibus DP V1, communication module PROFINET
    • Protection Type : phase failure mains, thermal protection starter, thermal protection motor, current overload motor, motor underload motor, excessive acceleration time motor, motor phase loss detection motor, protection against line phase inversion mains, external thermal protection motor, protection delta inside wiring starter, short-circuit between motor phase and earth motor
    • Safety Function : STO (safe torque off): SIL 1 conforming to IEC 61508, STO (safe torque off): PL c/category 2 conforming to ISO 13849
    • Transmission Frame : RTU, TCP/UDP
    • Transmission Rate : 4.8…38.4 kbps, 100 BASE TX
    • Utilisation Category : AC-3A, AC-53A
    • Uc Control Circuit Voltage2 : 24 V DC, 110...230 V AC 50-60 Hz - 15...10 %
    • Ue Rated Operational Voltage2 : 230 V 18.5 kW in the motor supply line normal duty, 400 V 37 kW in the motor supply line normal duty, 440 V 37 kW in the motor supply line normal duty, 500 V 45 kW in the motor supply line normal duty, 525 V 45 kW in the motor supply line normal duty, 660 V 55 kW in the motor supply line normal duty, 690 V 55 kW in the motor supply line normal duty, 230 V 15 kW in the motor supply line heavy duty, 400 V 30 kW in the motor supply line heavy duty, 208 V 20 hp normal duty, 230 V 25 hp normal duty, 460 V 50 hp normal duty, 575 V 60 hp normal duty, 208 V 15 hp heavy duty, 460 V 40 hp heavy duty, 208...690 V AC - 15...10 %)
    • Environmental Class During Operation2 : class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
    • Maximum Acceleration Under Vibratory Load During Storage2 : 1 gn at 9…200 Hz, 1.5 gn at 200…500 Hz
    • Maximum Acceleration Under Vibratory Load During Transport2 : 1 gn at 9…200 Hz, 1.5 gn at 200…500 Hz
    • Carbon Footprint Of The Distribution Phase A4 : 1.675854202443732, 2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 13.01528786188521, 13 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 1 kg CO2 eq., 1.194076559362415
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 199 kg CO2 eq., 198.7325140994889
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 800 kg CO2 eq., 799.7502512485936
    • Environmental Class During Operation3 : class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
    • Maximum Acceleration Under Vibratory Load During Storage3 : 1 gn at 9…200 Hz, 1.5 gn at 200…500 Hz
    • Maximum Acceleration Under Vibratory Load During Transport3 : 1 gn at 9…200 Hz, 1.5 gn at 200…500 Hz
    • Device Connection : in the motor supply line, inside delta
    • Uc Control Circuit Voltage5 : 24 V DC, 110...230 V AC 50-60 Hz - 15...10 %
    • Ue Rated Operational Voltage5 : 208...690 V AC - 15...10 %), 230 V 18.5 kW in the motor supply line normal duty, 400 V 37 kW in the motor supply line normal duty, 440 V 37 kW in the motor supply line normal duty, 500 V 45 kW in the motor supply line normal duty, 525 V 45 kW in the motor supply line normal duty, 660 V 55 kW in the motor supply line normal duty, 690 V 55 kW in the motor supply line normal duty, 230 V 15 kW in the motor supply line heavy duty, 400 V 30 kW in the motor supply line heavy duty, 440 V 30 kW in the motor supply line heavy duty, 500 V 37 kW in the motor supply line heavy duty, 525 V 37 kW in the motor supply line heavy duty, 660 V 45 kW in the motor supply line heavy duty, 690 V 45 kW in the motor supply line heavy duty, 208 V 20 hp normal duty, 230 V 25 hp normal duty, 460 V 50 hp normal duty, 575 V 60 hp normal duty, 208 V 15 hp heavy duty, 230 V 20 hp heavy duty, 460 V 40 hp heavy duty, 575 V 50 hp heavy duty
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Pre Comm Date : 2025-03-26
    • Device Type : Soft starter - Soft starter
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2309012EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Apparent Power : 80 VA
    • Data Format : 8 bits, configurable odd, even or no parity 1or 2 stop
    • Device Short Name : ATS490
    • Method Of Access : slave Modbus serial
    • Number Of Addresses : 0-247 Modbus serial
    • Operating Position : vertical +/- 10 degree
    • Package Weight Lbs : 8.140 kg
    • Phase : 3 phase
    • Power Loss Per Device Current Dependent : 11 W
    • Power Loss Static Current Independent : 19 W
    • Power Losses : 914 W during starting at 40 °C at 400% Ie
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Destination : asynchronous motors
    • Product Or Component Type : soft starter
    • Product Specific Application : process and infrastructures
    • Range Of Product : Altivar Soft Starter ATS490
    • Returnability : Yes
    • Safety Level : security level (SL) 1 IEC 62443-4-2
    • Supply Frequency : 50...60 Hz - 20...20 %
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 1 014 kg CO2 eq.
    • Type Of Polarization : no impedance Modbus serial
    • Volume Of Cooling Air : 31 m3/h
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • Ie Rated Operational Current2 : normal duty 75 A in line 40 °C)
    • Ui Rated Insulation Voltage2 : 690 V
    • Uimp Rated Impulse Withstand Voltage2 : 6 kV
    • Maximum Acceleration Under Shock Impact During Operation2 : 15 gn at 11 ms
    • Maximum Acceleration Under Shock Load During Storage2 : 10 gn at 11 ms
    • Maximum Acceleration Under Shock Load During Transport2 : 10 gn at 11 ms
    • Maximum Acceleration Under Vibrational Stress During Operation2 : 1 gn at 13…200 Hz
    • Maximum Deflection Under Vibratory Load During Operation2 : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Storage2 : 1.75 mm at 2...9 Hz
    • Maximum Deflection Under Vibratory Load During Transport2 : 1.75 mm at 2...9 Hz
    • With Safety Function Safe Brake Management Sbc Sbt2 : false
    • With Safety Function Safe Direction Sdi2 : false
    • With Safety Function Safe Operating Stop Sos2 : false
    • With Safety Function Safe Position Sp2 : false
    • With Safety Function Safe Speed Monitor Ssm2 : false
    • With Safety Function Safe Stop 1 SS1 : false
    • With Safety Function Safe Torque Off Sto2 : true
    • With Safety Function Safely Limited Position Slp2 : false
    • With Safety Function Safely Limited Speed Sls2 : false
    • With Sft Fct Safe Stop 2 Ss : false
    • Medium Desc : Soft starter, Altivar Soft Starter ATS490, 75A, 208 to 690V AC, control supply 110 to 230V AC
    • Country Of Origin 6 : US
    • Stocking Flag : N
    • Product Kit Identifier : N
    • Maximum Acceleration Under Shock Impact During Operation3 : 15 gn at 11 ms
    • Maximum Acceleration Under Shock Load During Storage3 : 10 gn at 11 ms
    • Maximum Acceleration Under Shock Load During Transport3 : 10 gn at 11 ms
    • Maximum Acceleration Under Vibrational Stress During Operation3 : 1 gn at 13…200 Hz
    • Maximum Deflection Under Vibratory Load During Operation3 : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Storage3 : 1.75 mm at 2...9 Hz
    • Maximum Deflection Under Vibratory Load During Transport3 : 1.75 mm at 2...9 Hz
    • With Safety Function Safe Brake Management Sbc Sbt3 : false
    • With Safety Function Safe Direction Sdi3 : false
    • With Safety Function Safe Operating Stop Sos3 : false
    • With Safety Function Safe Position Sp3 : false
    • With Safety Function Safe Speed Monitor Ssm3 : false
    • With Safety Function Safe Torque Off Sto3 : true
    • With Safety Function Safely Limited Position Slp3 : false
    • With Safety Function Safely Limited Speed Sls3 : false
    • With Sft Fct Safe Stop 2 Ss4 : false
    • Pep Code : ENVPEP2309012EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : referent product
    • Functional Unit Description : The aim of soft starter is to drive an asynchronous motor (squirrel cage) by limitation of the current during acceleration and deceleration phase with a torque control. It’s based on three phases dimmer with Silicon controlled rectifier (thyristor). The rating of softstarter is given by nominal current 75A in the case study which lead to drive several power motor depending of power network voltage ie 230V power motor of 18,5kW and 690V power motor of 55kW. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 3,6% uptime in active phase, 46,4% uptime in stand by phase and 50% in control phase.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Indonesia, ID
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Display Screen Available : true
    • Internal Bypass : true
    • Material Declaration : true
    • On Load Factor : 50 %
    • Operating Rate : 10 cyc/h
    • Overload Current : 400 % Ie for 13 s
    • With Safety Function Cybersecurity : true
    • In Rated Current Pwr Loss Specifctn2 : 75 A
    • Torque Control : true
    • Global Commercial Status : Commercialised
    • In Rated Current Pwr Loss Specifctn3 : 75 A
    • Ie Rated Operational Current5 : normal duty 75 A in line 40 °C)
    • With Safety Function Safe Stop 1 Ss1 5 : false
  • Environment Attributes Main
    • Take Back : Nej, No
    • Ambient Air Temperature For Operation : -25-40 °C (without derating), -25-40 °C (without derating), -25-40 °C (without derating), -25-40 °C (without derating), 40-60 °C (with current derating of 1 % per °C above 40 °C)
    • Ambient Air Transport Temperature : -40-70 °C, -40-70 °C
    • EU ROHS Directive : Compliant By Exemption , Compliant with Exemptions
    • Operating Altitude : <= 6561.68 ft (2000 m) without derating, <= 6561.68 ft (2000 m) without derating, > 2000...4800 m with current derating 1 % per 100 m above 2000 m, > 2000...4800 m with current derating 1 % per 100 m above 2000 m, <= 6561.68 ft (2000 m) without derating, <= 6561.68 ft (2000 m) without derating, > 2000...4800 m with current derating 1 % per 100 m above 2000 m, > 2000...4800 m with current derating 1 % per 100 m above 2000 m
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 1014.3679839717739
    • Ambient Air Temperature For Storage : -40-70 °C
    • Circularity Profile : ENVEOLI2309012EN
    • Environmental Disclosure : ENVPEP2309012EN
    • IP Degree Of Protection : IP20
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % without condensation or dripping water EN/IEC 60068-2-3
    • Pep Code : ENVPEP2309012EN
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : soft starter
    • Range Of Product : Altivar Soft Starter ATS490
  • Output Attributes
    • Analogue Output Type : current output AQ1 : 0...20 mA/4...20 mA , impedance< 500 Ohm, voltage output AQ1 : 0...10 V , impedance> 470 Ohm
    • Discrete Output Type : programmable digital output DQ1 <= 30 V 100 mA, programmable digital output DQ2 <= 30 V 100 mA
    • Relay Output Type : relay outputs R1A, R1C NO, relay outputs R2A, R2C NO, relay outputs R3A, R3C NO
    • Analogue Output Number : 1
    • Discrete Output Number : 2
    • Output Compatibility : open collector level 1 PLC IEC 65A-68
    • Relay Output Number : 3
    • Output Current Drift : 150-700 %
  • Input Attributes
    • Analogue Input Type : AI1/PTC1 : PTC/PT 100/PT 1000/KTY84 temperature probe, PTC2 : PTC/PT 100/PT 1000/KTY84 temperature probe, PTC3 : PTC/PT 100/PT 1000/KTY84 temperature probe
    • Discrete Input Logic : digital input DI1 0...< 5 V <= 2 mA > 11 V, >= 5 mA, digital input DI2 0...< 5 V <= 2 mA > 11 V, >= 5 mA, digital input DI3 0...< 5 V <= 2 mA > 11 V, >= 5 mA, digital input DI4 0...< 5 V <= 2 mA > 11 V, >= 5 mA, digital input STO 0...< 5 V <= 2 mA > 11 V, >= 5 mA
    • Discrete Input Type : DI1) digital input, 4.4 kOhm, DI2) digital input, 4.4 kOhm, DI3) digital input, 4.4 kOhm, DI4) digital input, 4.4 kOhm, STO) digital input, > 1 kOhm
    • Input Compatibility : DI1 discrete input level 1 PLC EN/IEC 61131-2, DI2 discrete input level 1 PLC EN/IEC 61131-2, DI3 discrete input level 1 PLC EN/IEC 61131-2, DI4 discrete input level 1 PLC EN/IEC 61131-2, STO discrete input level 1 PLC EN/IEC 61131-2
    • Analogue Input Number : 1
    • Discrete Input Number : 5
  • Specifications
    • Country of Origin : Mexico, Philippines
    • Depth : 234 mm
  • Batteries & Runtime Attributes
    • Removable Battery : Yes