SQUARE D

Power distribution block, Linergy, 1 pole, 1 line, 12 load, 380A Cu, 310A Al, 600V

PWR DISTR BLK 600V 380A

SQD9080LBA165112 9080LBA165112 785901097365
173.46 / EACH
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 3.13 in
  • Height: 5.5 in
  • Number of Poles: 1
  • Short Circuit Current Rating: 65 kA
  • Warranty Length: 18 mth
  • Width: 3.17 in
Linergy power distribution blocks are for terminating wires and are designed to NEMA standards. This one pole block has one lug opening on the line (main) side and twelve lug openings on the load (branch) side. The line side lug is rated to accept one #4 to 500 kcmil copper or aluminum wire. The load side lug is rated to accept one #14 to 2 copper or aluminum wire. The lugs are made of aluminum. The lugs are rated for 380 amperes with copper wire and 310 amperes with aluminum wire. The lugs are rated to 600 volts. The housing is made of general purpose phenolic. These Linergy power distribution blocks are UL component recognized and CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
Linergy power distribution blocks are for terminating wires and are designed to NEMA standards. This one pole block has one lug opening on the line (main) side and twelve lug openings on the load (branch) side. The line side lug is rated to accept one #4 to 500 kcmil copper or aluminum wire. The load side lug is rated to accept one #14 to 2 copper or aluminum wire. The lugs are made of aluminum. The lugs are rated for 380 amperes with copper wire and 310 amperes with aluminum wire. The lugs are rated to 600 volts. The housing is made of general purpose phenolic. These Linergy power distribution blocks are UL component recognized and CSA certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CSA file 70361 class 6228 01 || UL recognized E60616 CCN XCFR2 || CE
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Packaging Without Single Use Plastic : No
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Take-Back : No
    • Eu Rohs Directive : Compliant
  • Complementary
    • [Ics] Rated Service Breaking Capacity : 100 kA UL 508 A
    • Ambient Air Temperature For Operation : -40-302 °F
    • Height : 5.5 in
    • Mounting Support : surface mount
    • Electrical Connection : tin plated aluminium lugs
    • Connections - Terminals : load lug 50 lbf.in AWG 3...AWG 2 copper or aluminium || load lug 45 lbf.in AWG 6...AWG 4 copper or aluminium || load lug 40 lbf.in AWG 8 copper or aluminium || load lug 35 lbf.in AWG 14...AWG 10 copper or aluminium || line lug 375 lbf.in AWG 4...500 kcmil copper or aluminium
    • Wire Stripping Length : line: 1.31 in || load: 0.75 in for top connection || load: 1.19 in for bottom connection
    • Number Of Cables : line 1 , AWG 4...500 kcmil, copper or aluminium || load 12 , AWG 14...AWG 2, copper or aluminium
    • Material : phenolic: block
    • Width : 3.17 in
    • Depth : 3.13 in
    • Product Compatibility : 9080LB51
    • Number Of Poles : 1
    • [Ue] Rated Operational Voltage : 600 V AC/DC
    • Number Of Terminals : 1 line || 12 load
  • Specifications
    • Country of Origin : United States
    • Width : 3.17 in
    • Height : 5.5 in
    • Range Of Product : 9080LB
    • Product Or Component Type : Power Distribution Block
    • Short-Circuit Current : 65 kA
    • Line Rated Current : 380-380 A copper || 310-310 A aluminium