SQUARE D

Roof Top Unit, Heat Pump & Indoor Air Quality Ctrl: BACnet MS/TP, RH sensor & control, Silver Case/Fascia [TAA]

ROOF TOP UNIT, HEAT PUMP & IND

SQDSE8650U0B00 SE8650U0B00 3606489928414
630.60 / EA
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Depth: 25 mm
  • Height: 120 mm
  • Input Voltage: ...10 V
  • Net Weight: 340 g
  • Output Voltage: ...10 V, 24 V
  • Surface Finish: Matte
  • Weight: 340 g
  • Width: 86 mm
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: LEAD, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Specifications
    • Country of Origin : Mexico
    • Weight : 340 g
    • Housing Colour : silver
    • Height : 120 mm
    • Ambient Air Temperature For Operation : 0-50 °C
    • Calibration Certificate : 1 Pt
    • Standards : EN/IEC 60730-1 || FCC part 15 Subpart B || ICES-003 || ETSI EN 300 328 || ETSI EN 301 489-1:v1.9.2 || FCC part 15 Subpart C || UL 60730-2-9 || ETSI EN 301 489-17:v2.2.1, 2012
    • Output Voltage : 24 V AC/DC relay output || 0...10 V AC/DC voltage output
    • Targeted Region : North America.
    • Product Or Component Type : roof top unit
    • Output Type : 5 xrelay output || 4 xuniversal
    • Humidity Measurement Drift : Less Than 1 % Yearly
    • Product Name : SE8000 Series
    • Net Weight : 340 g
    • Range : EcoStruxure Building Expert
    • Input Type : dry contact 2 || analog 5
    • Communication Port Protocol : BACnet MS/TP || Modbus RTU
    • Directives : 2014/30/EU - electromagnetic compatibility || 2014/35/EU - low voltage directive || 2014/53/EU - radio equipment directive
    • Awg Gauge : AWG 22...AWG 18
    • Ambient Air Temperature For Storage : -30-50 °C
    • Output Current : 1 A relay output || 3 A relay output inrush) || 0.3 A universal output || 1.5 A universal output inrush)
    • Input Voltage : 0...10 V
    • Sensor Type : 10 kOhm T2 NTC thermistor Temperature || space RH sensor Humidity || bulk polymer Humidity
    • Relative Humidity : 0-75 %
    • Temperature Setting Range : 12-37.5 °C cooling || 4.5-32 °C heating
    • Width : 86 mm
    • Humidity Setting Range : 30-95 %
    • Market Segment : Lodging/Hotel || small commercial || buildings || healthcare || non-critical buildings || office || residential || school
    • Temperature Resolution : 0.1 °C
    • Depth : 25 mm
    • Device Application : staging equipment (RTU/HP)
    • Device Short Name : SE8600
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2405011
    • Packaging Without Single Use Plastic : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : 36265055-6713-4452-af94-2e6566ec0ebd
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: LEAD, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI2405011
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 165.71611043544635
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 13.917682140898627
    • Carbon Footprint Of The Distribution Phase [A4] : 0.5 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0 kg CO2 eq.
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 181 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 0.4582418400046602
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 180.5631801106675
  • Complementary
    • Surface Finish : Matte
    • Surface Treatment : untreated
  • Compliance
    • Compliance : TAA