pump control relay, Harmony Control Relays, 5A, 1CO, 208...480V AC

pump control relay, Harmony Control Relays, 5A, 1CO, 208...480V AC

SQDRM35BA10 RM35BA10 3389119405195
319.77 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Operating Position: Any Position
  • Warranty Length: 18 mth
  • Width: 1.38 in
This Harmony RM35-BA control relay allows monitoring of pump control. This modular pump control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RM35-BA control relay allows monitoring of pump control. This modular pump control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications
  • Uc Control Circuit Voltage
    • 208...480 V
    • 230 V
  • Insulation Resistance
    • > 500 MOhm 500 V DC between supply and relay output 60255-5
    • > 500 MOhm 500
  • Connections Terminals
    • screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end
    • screw terminals, 1 x
  • Overvoltage Category
    • III conforming to IEC 60664-1
  • Mounting Support
    • 35 mm symmetrical DIN rail conforming to IEC 60715
  • Supply Voltage Limits
    • 183-528 V AC
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Response Time
    • < 300 ms (in the event of a fault)
  • Input Current
    • 11 A permanent at 25 °C E1-L2 terminals
    • 50 A non repetitive < 1 s at 25 °C E1-L2 terminals
    • 50 A non repetitive < 1 s at 25
  • Carbon Footprint Of The Installation Phase A5
    • 0.03990970767888307
    • 0 kg CO2 eq.
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0.2 kg CO2 eq.
    • 0.23091121291448516
  • Ui Rated Insulation Voltage
    • 400 V IEC 60664-1
  • Status Led
    • 1 LED Green power ON
    • 1 LED Yellow fault
    • 1 LED Yellow relay ON
  • Maximum Switching Voltage
    • 250 V AC/DC
  • Ip Degree Of Protection
    • IP20 IEC 60529 terminals)
    • IP30 IEC 60529 casing)
  • Maximum Measuring Cycle
    • 140 ms as true rms value
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 8 kg CO2 eq.
    • 8.282465095986037
  • Maximum Switching Current
    • 5 A AC/DC
  • Marking
    • CE : EMC 89/336/EEC
    • CE : 73/23/EEC
  • Time Delay Type
    • adjustable 1...60 s, +/- 10 % Ti- inhibition time delay upon startup
    • adjustable 1...60 s, +/- 10 % Ti- inhibition ti
  • Measurement Range
    • 208...480 V AC
    • 1...10 A
  • Vibration Resistance
    • 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
    • 1 gn (f= 57.6-150 Hz) conforming to IEC 60068-2-6/IEC 60
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • Charge Point Operator
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • Electrician
    • System Integrator
    • IT Channel Partner
  • Measurement Error
    • 1 % by volt over the whole range
    • +/- 0.05 %/°C
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 94 kg CO2 eq.
    • 93.82239999999997
  • Electromagnetic Compatibility
    • emission standard for industrial environments IEC 61000-6-4
    • emission standard for residential, commercial and light-industrial environments IEC 61000-6-3
    • emission standard for residential, comme
  • Supply Frequency
    • 50/60 Hz +/- 10 %
  • Hysteresis
    • 5-5 % threshold
  • Relative Humidity
    • 95-95 % 55-55 °C IEC 60068-2-30
  • Persona Type Ids
    • BM9
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SC
    • SI
    • VR
  • Dielectric Strength
    • 2 kV AC 50 Hz shock wave 4 kV)
  • Us Rated Supply Voltage
    • 208...480 V AC 50/60 Hz, non self-powered
    • 230 V AC 50/60 Hz, non self-powered
    • 230 V AC 50/60
  • Relay Monitored Parameters
    • overcurrent and undercurrent control
    • phase sequence on 3-phase supply
    • phase failure on 3-phase supply
  • Carbon Footprint Of The Distribution Phase A4
    • 0.016084271378708548
    • 0 kg CO2 eq.
  • Tightening Torque
    • 0.6-1 N.m IEC 60947-1
  • Minimum Switching Current
    • 10 mA 5 V DC
  • Repeat Accuracy
    • +/- 1 % input and measurement circuit
    • +/- 1 % time delay
  • Maximum Power Consumption In Va
    • 5 VA AC
  • Utilisation Category
    • AC-12 IEC 60947-5-1
    • AC-13 IEC 60947-5-1
    • AC-14 IEC 60947-5-1
    • AC-15 IEC 60947-5-1
    • DC-12 IEC 60947-5-1
    • DC-13 IEC 60947-5-1
  • Resistance Across Terminals
    • 0.01 Ohm E1-L2 terminals
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Operating Rate
    • <= 360 operations/hour full load
  • Shock Resistance
    • 15 gn 11 ms IEC 60255-21-1
  • Product Certifications
    • C-tick
    • CSA
    • GOST
    • UL
    • GL
  • Conformance Attributes
    • Standards : IEC 60255-6
  • Complementary Attributes
    • Control Circuit Voltage Limits : - 15 % + 10 % Un
    • Line Rated Current : 5 A
  • Important Information Attributes
    • Country Id : US
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • ETIM 10 : EC001440
    • Manufacturing Carbon Footprint : 8.28246509598604
    • Distribution Carbon Footprint : 1.60842713787085e-02
    • Installation Carbon Footprint : 3.99097076788831e-02
    • Use Carbon Footprint : 93.8224
    • End Of Life Carbon Footprint : 0.230911212914485
    • Legacy WEEE Scope : Out
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1601004EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS Eur In Scope : No
    • ROHS Eur Status : Compliant with Exemptions
    • ROHS Eur Conformity Date : 1918
    • ROHS Eur Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS Eur Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • China ROHS Label : 5
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : RM3
    • Contacts Type And Composition : 1 C/O
    • Control Type : without test button
    • Electrical Durability : 100000 cycles
    • Housing Material : self-extinguishing plastic
    • Immunity To Microbreaks : 500 ms
    • Measurement Accuracy : +/- 10 % of the full scale value
    • Mechanical Durability : 30000000 cycles
    • Operating Position : any position
    • Package Weight Lbs : 123.0 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : pump control relay
    • Product Specific Application : for 3-phase and single-phase pump
    • Range Of Product : Harmony Control Relays
    • Relay Name : RM35BA
    • Relay Type : pump control relays
    • Reset Time : 2000 ms
    • Returnability : Yes
    • Run Up Delay At Power Up : 0.5 s
    • Sustainable Packaging : Yes
    • Switching Capacity In Va : 1250 VA
    • Total Lifecycle Carbon Footprint : 102 kg CO2 eq.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 102.3917702879581
  • General Attributes
    • Product Or Component Type : pump control relay
    • Range Of Product : Harmony Control Relays
  • Output Attributes
    • Nominal Output Current : 5 A
    • Output Contacts : 1 C/O
  • Environment Attributes
    • China ROHS Url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=648356&lang=en-us
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 102.391770287958
    • Ambient Air Temperature For Operation : -20-50 °C
    • Ambient Air Temperature For Storage : -40-70 °C
    • Circularity Profile : ENVEOLI1601004EN
    • Environmental Disclosure : ENVPEP1601004EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Indonesia
    • Width : 1.38 in