ClimaSys CVHD outdoor HD fan-box without grille and filter 550 m3/h 115VAC

CLIMASYS CVHD OUTDOOR HD FAN-B

SQDNSYCVF550M115FB NSYCVF550M115FB 3606480678776
441.82 / EA
http://schema.org/OutOfStock
  • Height: 8.78 in
  • Input Voltage: 115 V, 50/60 Hz
  • Warranty Length: 18 mth
  • Width: 8.78 in
ClimaSys outdoor heavy duty 78.102W fanbox without grille and filter ensures effective temperature control inside PHD, S3HD and SFHD enclosures. The fan performs free flow rate of 550 m3/h at 50 Hz and 550 m3/h at 60 Hz. Motor mounted on ball bearing. Equipped with spring clamp terminal. The external width is 223mm, height is 223mm and depth is 90mm. The accessory is made up of 1 fanbox and 4 screws. The color is dark grey (RAL 7016). Ingress protection rating is IP44 (IP55 for grid). Ingress protection rating is IP44 (IP55 for grid). Rated current is 0.7-0.8A 50 Hz. Noise level is 60-60 dB. The operating temperature is -40-70 °C. Maximum pressure is 300 Pa at flow rate of 0 m³/h. Net weight is 1.7kg. Certification CE, UL conforming to UL 508A, CSA conforming to CSA C22.2 and ecodesign directive 2009/125/EC. Please note, that overfrequent filter replacement should be avoided, flow rates depends on the work point,. see ProClima software, surrounding environment must be relatively clean, filter must be cleaned and replaced regularly and outside temperature must be 5 °C lower than inside temperature.
QTY
  • Product Description
  • Features
  • Specifications
ClimaSys outdoor heavy duty 78.102W fanbox without grille and filter ensures effective temperature control inside PHD, S3HD and SFHD enclosures. The fan performs free flow rate of 550 m3/h at 50 Hz and 550 m3/h at 60 Hz. Motor mounted on ball bearing. Equipped with spring clamp terminal. The external width is 223mm, height is 223mm and depth is 90mm. The accessory is made up of 1 fanbox and 4 screws. The color is dark grey (RAL 7016). Ingress protection rating is IP44 (IP55 for grid). Ingress protection rating is IP44 (IP55 for grid). Rated current is 0.7-0.8A 50 Hz. Noise level is 60-60 dB. The operating temperature is -40-70 °C. Maximum pressure is 300 Pa at flow rate of 0 m³/h. Net weight is 1.7kg. Certification CE, UL conforming to UL 508A, CSA conforming to CSA C22.2 and ecodesign directive 2009/125/EC. Please note, that overfrequent filter replacement should be avoided, flow rates depends on the work point,. see ProClima software, surrounding environment must be relatively clean, filter must be cleaned and replaced regularly and outside temperature must be 5 °C lower than inside temperature.
  • Features
    • Free flow rate: 550 m3/h (50/60 Hz).
    • UL Recognized (cURus)Rated Type 12
    • Minimal depth inside the enclosure (90 mm).
    • Allows multiple cooling architectures (see
    • Material: polyamide
    • Color: RAL 7016 dark grey
  • Physical Attributes
    • Color : dark grey RAL 7016)
  • Conformance Attributes
    • Product Certifications : CE, UL conforming to UL 508 A, CSA conforming to CSA C22.2, ecodesign directive 2009/125/EC
  • Complementary Attributes
    • Line Rated Current : 0.7-0.8 A 50 Hz
    • Maximum Pressure : 300 Pa flow rate 0 m³/h
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB, SI
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Condition Of Use : overfrequent filter replacement should be avoided, flow rates depends on the work point, see ProClima software, surrounding environment must be relatively clean, filter must be cleaned and replaced regularly, outside temperature must be 5 °C lower than inside temperature
    • Device Composition : 1 fanbox, 4 screw
    • Carbon Footprint Of The Distribution Phase A4 : 4.954533831566484, 5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 4 kg CO2 eq., 3.728749175527124
    • Carbon Footprint Of The Installation Phase A5 : 0.27783457389102095, 0.3 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 16 kg CO2 eq., 16.23540718026087
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 0 kg CO2 eq., 0
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-09-16
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1107017EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Noise Level : 60-60 dB
    • Package Weight Lbs : 2.500 kg
    • Power Range : 78...102 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : fanbox without grille and filter
    • Product Specific Application : outdoor heavy duty
    • Range : ClimaSys
    • Returnability : No
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 25 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Us Rated Supply Voltage2 : 115 V AC +/- 10 %
    • Connections Terminals : spring clamp terminal
    • Medium Desc : ClimaSys CVHD outdoor HD fan-box without grille and filter 550 m3/h 115VAC
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP110717EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0008-ed3-EN-2023 10 19
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : "Transfer 1 m3 of air per hour for the ventilation and air treatment and smoke exhaust and filtration of a building/Confined space over the reference lifetime of 17 years. "
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Bearing Type : ball
    • Global Commercial Status : Commercialised
    • Product Name : ClimaSys CV
    • Us Rated Supply Voltage5 : 115 V AC +/- 10 %
  • Environment Attributes Main
    • Take Back : No, Nej
    • Air Flow : free flow rate: 550 m3/h at 50 Hz, 550 m3/h at 60 Hz
    • EU ROHS Directive : Compliant By Exemption , Compliant with Exemptions
    • IP Degree Of Protection : IP55 grid:, IP44
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 25.1965247612455
    • Ambient Air Temperature For Operation : -40-70 °C
    • Ambient Air Temperature For Storage : -40-80 °C
    • Circularity Profile : ENVEOLI1107017EN
    • Environmental Disclosure : ENVPEP110717EN
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP110717EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0008-ed3-EN-2023 10 19
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : fanbox without grille and filter
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Input Voltage : 115 V AC 50/60 Hz
  • Specifications
    • Height : 8.78 in
    • Width : 8.78 in