Panelboard interior, NQ, main lugs, 100A, Cu bus, 18 pole spaces, 1 phase, 3 wire, 240VAC, 48VDC

PNLBD INT NQ 100A MLO 18 CKT 1

SQDNQ18L1C NQ18L1C 785901501992
1009.67 / EACH
http://schema.org/OutOfStock
  • Enclosure Depth: 5.75 in, 6.5 in
  • Enclosure Height: 26 in
  • Enclosure Width: 20 in
  • Height: 21 in, 26 in
  • Net Weight: 5.53 kg
  • Number of Spaces: 18
  • Warranty Length: 18 mth
  • Weight: 5.53 kg
  • Width: 10.44 in, 20 in
NQ Panelboard interiors may be used in a wide variety of applications including: commercial buildings; industrial buildings; data centers; stadiums; and offices. NQ Panelboards are versatile panelboards that feature a wide selection of bolt-on and plug-on branch circuit breakers, integral main circuit breakers, branch mounted SPDs, and a wide variety of ready to install accessory kits. The interiors are field convertible to support top or bottom feed. This main lugs interior is rated 100A for 240VAC and 48VDC, has a plated copper bus, and 18 pole spaces. NQ Panelboards are convertible from main lugs to main circuit breaker. NQ Panelboards offer 200% rated neutrals for nonlinear loads. Factory installed options include phenolic nameplates, power monitoring of mains and branch circuits, split bus interiors, and neutral assemblies which support up to 36 100A branch circuit breakers. NQ Panelboards are available with IP2X per IEC 60529 barriers for UL service entrance applications. Interior has an interrupt current rating of up to 65kA (depending upon the circuit breakers installed). This NQ panelboard interior is UL listed for applications in the USA and Canada. Interior accepts QOB, QOBVH and QHB bolt-on and QO, QOVH and QH plug-on branch circuit breakers. Standard mechanical main lug connections will accept copper or aluminum wire. NQ Panelboard interiors are available with plated aluminum or copper bus. 100A branch circuit breakers may be installed on both sides of NQ Panelboard interiors.
QTY
  • Product Description
  • Features
  • Specifications
NQ Panelboard interiors may be used in a wide variety of applications including: commercial buildings; industrial buildings; data centers; stadiums; and offices. NQ Panelboards are versatile panelboards that feature a wide selection of bolt-on and plug-on branch circuit breakers, integral main circuit breakers, branch mounted SPDs, and a wide variety of ready to install accessory kits. The interiors are field convertible to support top or bottom feed. This main lugs interior is rated 100A for 240VAC and 48VDC, has a plated copper bus, and 18 pole spaces. NQ Panelboards are convertible from main lugs to main circuit breaker. NQ Panelboards offer 200% rated neutrals for nonlinear loads. Factory installed options include phenolic nameplates, power monitoring of mains and branch circuits, split bus interiors, and neutral assemblies which support up to 36 100A branch circuit breakers. NQ Panelboards are available with IP2X per IEC 60529 barriers for UL service entrance applications. Interior has an interrupt current rating of up to 65kA (depending upon the circuit breakers installed). This NQ panelboard interior is UL listed for applications in the USA and Canada. Interior accepts QOB, QOBVH and QHB bolt-on and QO, QOVH and QH plug-on branch circuit breakers. Standard mechanical main lug connections will accept copper or aluminum wire. NQ Panelboard interiors are available with plated aluminum or copper bus. 100A branch circuit breakers may be installed on both sides of NQ Panelboard interiors.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Standards : UL || CSA
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1404010EN
    • Packaging Without Single Use Plastic : No
    • Toxic Heavy Metal Free : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Circularity Profile : N/A
    • Take-Back : No
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 56.3473074724
  • Complementary
    • Height : 21 in
    • Phase : 1 phase 3 wires
    • Tightening Torque : 4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil) || 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil) || 31.07-31.07 N.m 107.2-152 mm² (AWG 4...300 kcmil)
    • [Iu] Rated Interrupted Current : 10 kA || 22 kA || 65 kA
    • Number Of Spaces : 18
    • Enclosure Nominal Height : 26 in
    • Net Weight : 5.53 kg
    • Enclosure Nominal Depth : 5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
    • Line Rated Current : 100 A
    • Width : 10.44 in
    • Enclosure Nominal Width : 20 in
    • [Ue] Rated Operational Voltage : 240 V AC || 48 V DC
  • Specifications
    • Country of Origin : Mexico
    • Width : 20 in
    • Height : 26 in
    • Weight : 5.53 kg
    • Circuit Breaker Type : QOB || QOB-VH || QHB
    • Product Or Component Type : interiors
    • Material : copper
    • Load Center Type : main lugs