Main circuit breaker busway tap left, EZ Meter-Pak, 600A, 240VAC max, 3ph/4W, 600A bus, 65kA, neut front, Type 1

EZM MAIN 600A CB NEUT FRONT BU

SQDEZM3600CBNFBTL EZM3600CBNFBTL 785901370390
4999.73 / EA
http://schema.org/OutOfStock
  • Certifications: UL
  • Depth: 11.41 in
  • Enclosure Material: Painted Steel
  • Height: 53.93 in
  • Material: Aluminium: Busbar
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 18.66 in
Square D EZ Meter-Pak main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. EZM main circuit breaker with busway side tap have an integral busway tap allowing for connection to I-Line or I-Line II plug in busway. This main circuit breaker unit supplies three phases in, three phases out with a four wire configuration. This unit has busway taps extending to the left of the main device and allows neutral front installation. It is rated for 208Y/120VAC or 240/120VAC delta and 600A. It comes with a factory installed 3 pole 600A circuit breaker. The compartment has four horizontal 600A rated busbars. The busbars come with Visi-Tite joint nuts for connections, eliminating the need for torque readings. It is compliant with UL standards and the steel enclosure has a rating of NEMA 1.
QTY
  • Product Description
  • Specifications
Square D EZ Meter-Pak main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. EZM main circuit breaker with busway side tap have an integral busway tap allowing for connection to I-Line or I-Line II plug in busway. This main circuit breaker unit supplies three phases in, three phases out with a four wire configuration. This unit has busway taps extending to the left of the main device and allows neutral front installation. It is rated for 208Y/120VAC or 240/120VAC delta and 600A. It comes with a factory installed 3 pole 600A circuit breaker. The compartment has four horizontal 600A rated busbars. The busbars come with Visi-Tite joint nuts for connections, eliminating the need for torque readings. It is compliant with UL standards and the steel enclosure has a rating of NEMA 1.
  • Environment
    • Product Certifications : UL Listed
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant with Exemptions
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Height : 53.93 in
    • Phase : 3 phase
    • [Ue] Rated Operational Voltage : 208Y/120 V AC || 240/120 V delta || 240/120 V delta AC
    • Material : aluminium: busbar
    • Bus Rated Current : 600 A
    • Enclosure Material : painted steel
    • Wiring Configuration : 4-wire
    • Width : 18.66 in
    • Depth : 11.41 in
    • Type Of Installation : indoor
    • Main Rated Current : 600 A
    • Electrical Connection : lugsneutral front || busway left side
  • Specifications
    • Width : 18.66 in
    • Height : 53.93 in
    • Range Of Product : EZ meter-pak
    • Main Type : Main Circuit Breaker
    • Provided Equipment : circuit-breaker 1 ) 3P 600 A 65 kA || closing plate
    • Product Or Component Type : meter center main unit