Load center interior, QO, main lugs, 400A, Al bus, 30 pole spaces, 1 phase, 3 wire, NQ enclosure

NQ 400A 30 CKT MLO 1PH AL

SQDQONQ30LS400 QONQ30LS400 785901552758
2210.40 / EACH
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Enclosure Depth: 5.75 in, 6.5 in
  • Enclosure Height: 50 in
  • Enclosure Width: 20 in
  • Height: 50 in
  • Number of Spaces: 30
  • Warranty Length: 18 mth
  • Width: 20 in
NQ Panelboard interiors may be used in a wide variety of applications including: commercial buildings; industrial buildings; data centers; stadiums; and offices. NQ Panelboards are versatile panelboards that feature a wide selection of bolt-on and plug-on branch circuit breakers, integral main circuit breakers, branch mounted SPDs, and a wide variety of ready to install accessory kits. The interiors are field convertible to support top or bottom feed. This main lugs interior is rated 400A for 240VAC, has a plated aluminum bus, and 30 pole spaces. NQ Panelboards are convertible from main lugs to main circuit breaker. NQ Panelboards offer 200% rated neutrals for nonlinear loads. Factory installed options include phenolic nameplates, power monitoring of mains and branch circuits, split bus interiors, and neutral assemblies which support up to 36 100A branch circuit breakers. NQ Panelboards are available with IP2X per IEC 60529 barriers for UL service entrance applications. Interior has an interrupt current rating of up to 65kA (depending upon the circuit breakers installed). This NQ panelboard interior is UL listed for applications in the USA and Canada. Interior accepts QOB, QOBVH and QHB bolt-on and QO, QOVH and QH plug-on branch circuit breakers. Standard mechanical main lug connections will accept copper or aluminum wire. NQ Panelboard interiors are available with plated aluminum or copper bus. 100A branch circuit breakers may be installed on both sides of NQ Panelboard interiors.
QTY
  • Product Description
  • Features
  • Specifications
NQ Panelboard interiors may be used in a wide variety of applications including: commercial buildings; industrial buildings; data centers; stadiums; and offices. NQ Panelboards are versatile panelboards that feature a wide selection of bolt-on and plug-on branch circuit breakers, integral main circuit breakers, branch mounted SPDs, and a wide variety of ready to install accessory kits. The interiors are field convertible to support top or bottom feed. This main lugs interior is rated 400A for 240VAC, has a plated aluminum bus, and 30 pole spaces. NQ Panelboards are convertible from main lugs to main circuit breaker. NQ Panelboards offer 200% rated neutrals for nonlinear loads. Factory installed options include phenolic nameplates, power monitoring of mains and branch circuits, split bus interiors, and neutral assemblies which support up to 36 100A branch circuit breakers. NQ Panelboards are available with IP2X per IEC 60529 barriers for UL service entrance applications. Interior has an interrupt current rating of up to 65kA (depending upon the circuit breakers installed). This NQ panelboard interior is UL listed for applications in the USA and Canada. Interior accepts QOB, QOBVH and QHB bolt-on and QO, QOVH and QH plug-on branch circuit breakers. Standard mechanical main lug connections will accept copper or aluminum wire. NQ Panelboard interiors are available with plated aluminum or copper bus. 100A branch circuit breakers may be installed on both sides of NQ Panelboard interiors.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Standards : UL || CSA
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2212001
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : N/A
    • Take-Back : No
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Phase : 1 phase 3 wires
    • Tightening Torque : 4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil) || 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil) || 31.07-31.07 N.m 107.2-152 mm² (AWG 4...300 kcmil)
    • [Iu] Rated Interrupted Current : 10 kA || 22 kA || 65 kA
    • Number Of Spaces : 30
    • Enclosure Nominal Height : 50 in
    • Enclosure Nominal Depth : 5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
    • Line Rated Current : 400 A
    • Enclosure Nominal Width : 20 in
    • [Ue] Rated Operational Voltage : 240 V AC
  • Specifications
    • Country of Origin : United States
    • Width : 20 in
    • Height : 50 in
    • Circuit Breaker Type : QOB || QOB-VH || QHB
    • Product Or Component Type : Load Center Interior
    • Material : aluminium
    • Load Center Type : main lugs