SQUARE D

Load center, QO, 1 phase, 2 spaces, 4 circuits, 70A fixed main lugs, NEMA3R

LOADCENTER - RT

SQDQO24L70RB QO24L70RB 785901785132
90.39 / EACH
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Cover Type: Surface Cover
  • Enclosure Material: Steel
  • Number of Circuits: 4
  • Number of Spaces: 2
  • Surface Finish: Baked Enamel Gray
  • Warranty Length: 18 mth
QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. QO Load Centers are designed for residential and industrial use to protect electrical systems, equipment, and people. They are available in both traditional and plug on neutral configurations. There is 3 types of mains available. There is main circuit breaker, main lugs, and generator panel. Single and three phase options are available. The bus bars are tin plated copper and are shielded. Indoor and outdoors enclosures are an option. QO Load Centers enable the use of a full complement of accessories. This 1 phase load center has 2 spaces and 4 circuits. This system provides 70A fixed main lugs in a NEMA 3R enclosure. This product is UL rated.
QTY
  • Product Description
  • Features
  • Specifications
QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. QO Load Centers are designed for residential and industrial use to protect electrical systems, equipment, and people. They are available in both traditional and plug on neutral configurations. There is 3 types of mains available. There is main circuit breaker, main lugs, and generator panel. Single and three phase options are available. The bus bars are tin plated copper and are shielded. Indoor and outdoors enclosures are an option. QO Load Centers enable the use of a full complement of accessories. This 1 phase load center has 2 spaces and 4 circuits. This system provides 70A fixed main lugs in a NEMA 3R enclosure. This product is UL rated.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Line Rated Current : 70 A
    • Rated Current : 70 A
    • Ue Rated Operational Voltage : 120/240 V AC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer
    • Awg Gauge : AWG 12...AWG 3 aluminium, AWG 14...AWG 4 copper
    • Cover Type : surface cover
    • Electrical Connection : lugs
    • Material : tin plated aluminium: busbar
    • Product Or Component Type : Load Center
    • Tightening Torque : main lugs 35 lb.in, AWG 14...AWG 10, aluminium/copper, main lugs 45 lb.in, AWG 3, aluminium/copper, main lugs 40 lb.in, AWG 8...AWG 4, aluminium/copper, main lugs 35 lb.in, AWG 12...AWG10, aluminium/copper
    • Carbon Footprint Of The Distribution Phase A4 : 0.77411, 0.8 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.1 kg CO2 eq., 0.14009
    • Carbon Footprint Of The Installation Phase A5 : 0.050582, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 10 kg CO2 eq., 9.917
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 4 kg CO2 eq., 4.0395
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • H And D Domain : Safety
    • H And D Subrange : RESI
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : ENCLOSURES
    • Manufacturing Carbon Footprint : 9.917
    • Use Carbon Footprint : 4.0395
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 2532
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : RESIDENTIAL
    • Market Segmentation : Residential
    • Product Kit Identifier : N
    • Box Number : 1R
    • Device Composition : grounding bar (ordered separately)
    • Enclosure Material : welded galvannealed steel
    • Energy Efficiency Optimized : False
    • Load Center Type : Fixed Mains (lugs)
    • Number Of Circuits : 4
    • Number Of Spaces : 2
    • Number Of Tandem Circuit Breakers : 2
    • Phase : 1 phase 3 wires
    • Product Availability : Stock - Normally stocked in distribution facility
    • Range Of Product : QO
    • Returnability : Yes
    • Short Circuit Current : 65 kA
    • Software Version : EIME v5.9.4
    • Surface Finish : baked enamel Gray
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 15 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 14.921
    • Warranty In Months : 18
    • Pep Code : ENVPEP2212002EN
    • Database Version : 2022-01
    • Pep Verification Date : 2023-08-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : referent product
    • Functional-unit Description : Protect persons during 20 years against direct contact with live parts and allow grouping monitoring, control and protection devices in a single enclosure or a cabinet having the following dimensions 952.5mm x1219.2mm x 101.6mm, comply with UL 67 and CSA22.2 with an available offer:& 10-suitable for use on 120/240 Vac and 48 Vdc systems& 10-rated 30–125 A& 10-supplies from two to sixteen circuits& 10-surface or flush-mounted cover& 10-Types 1 & 3R& 10-main lugs only
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Energy model used: Tlaxcala Mexico
    • Energy Model - Installation [A5] : Electricity mix; AC; consumption mix, at consumer; 120V; US
    • Energy Model - Use [B6] : Electricity mix; AC; consumption mix, at consumer; 120V; US
    • Energy Model - End Of Life [C1-c4] : Electricity mix; AC; consumption mix, at consumer; 120V; US
    • Recyclability Potential, In % : 90
    • Offer Owner Code : 190788
    • Pn : 1
    • Height Nominal : 238 mm
    • Width Nominal : 124 mm
    • Certificate Agency : UL Listed
    • Air Pollution (M3) Total Life Cycle : 3024.9
    • Air Pollution (M3) Manufacturing [A1-a3] : 2633.2
    • Air Pollution (M3) Distribution [A4] : 32.193
    • Air Pollution (M3) Installation [A5] : 2.0981
    • Air Pollution (M3) Operational Energy Use [B6] : 343.04
    • Air Pollution (M3) End Of Life [C1-c4] : 14.371
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Total Life Cycle : 151.56
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 89.214
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Distribution [A4] : 10.877
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 49.182
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4] : 1.6306
    • Global Warming (Kg.Equivalent.Co2) Total Life Cycle : 14.921
    • Global Warming (Kg.Equivalent.Co2) Manufacturing [A1-a3] : 9.917
    • Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6] : 4.0395
    • Hazardous Waste Disposed Of (Kg) Total Life Cycle : 139.1
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 137.44
    • Hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 0.108
    • Hazardous Waste Disposed Of (Kg) End Of Life [C1-c4] : 1.5518
    • Materials For Recycling (Kg) Total Life Cycle : 2.3991
    • Materials For Recycling (Kg) End Of Life [C1-c4] : 1.2552
    • Non-hazardous Waste Disposed Of (Kg) Total Life Cycle : 33.001
    • Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 32.333
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 230.11
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 165.38
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Distribution [A4] : 10.932
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 51.116
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4] : 2.0297
    • Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle : 242.9
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 174.88
    • Total Use Of Primary Energy During The Life Cycle (Mj) Distribution [A4] : 10.947
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 54.382
    • Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4] : 2.032
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 12.786
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 9.5022
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 3.266
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 2.8125
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 2.8125
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 227.3
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 162.57
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Distribution [A4] : 10.932
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 51.116
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 2.0297
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 18.083
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 18.083
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : -5.2966
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : -8.5808
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 3.266
    • Water Pollution (M3) Total Life Cycle : 1264.8
    • Water Pollution (M3) Manufacturing [A1-a3] : 915.15
    • Water Pollution (M3) Distribution [A4] : 127.32
    • Water Pollution (M3) Installation [A5] : 7.6335
    • Water Pollution (M3) Operational Energy Use [B6] : 199.15
    • Water Pollution (M3) End Of Life [C1-c4] : 15.568
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : -5 °C, -5 °C, 40 °C
    • Nema Degree Of Protection : NEMA 3R weatherproof enclosure
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 14.921
    • Environmental Disclosure : ENVPEP2212002EN
    • Eu Rohs Directive : Compliant
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2212002EN
    • Pep Verification Date : 2023-08-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : Load Center
    • Phase : 1 phase 3 wires
    • Range Of Product : QO
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Mexico