Load center, QO, 1 phase, 3 spaces, 5 circuits, 30A main breaker, NEMA1, gnd bar, surface cover, trailer use

LD CTR QO MB 120V 30A 1PH 3SP

SQDQO35FM30TTS QO35FM30TTS 785901911623
83.00 / EACH
http://schema.org/OutOfStock
  • Cover Type: Surface Cover
  • Depth: 80 mm
  • Enclosure Material: Welded Sheet Steel
  • Height: 236 mm
  • Net Weight: 9.000 kg
  • Number of Circuits: 5
  • Number of Spaces: 3
  • Short Circuit Current Rating: 10 kA
  • Surface Finish: Baked Enamel Gray
  • Warranty Length: 18 mth
  • Weight: 9.000 kg
  • Width: 122 mm
QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. QO Load Centers are designed for residential and industrial use to protect electrical systems, equipment, and people. They are available in both traditional and plug on neutral configurations. There is 3 types of mains available. There is main circuit breaker, main lugs, and generator panel. Single and three phase options are available. The bus bars are tin plated copper and are shielded. Indoor and outdoors enclosures are an option. QO Load Centers enable the use of a full complement of accessories. This 1 phase load center has 3 spaces and 5 circuits. This system provides a 30A main breaker in a NEMA 1 enclosure. It also includes a ground bar, surface cover, and is UL rated. This product is for trailer use.
QTY
  • Product Description
  • Features
  • Specifications
QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. QO Load Centers are designed for residential and industrial use to protect electrical systems, equipment, and people. They are available in both traditional and plug on neutral configurations. There is 3 types of mains available. There is main circuit breaker, main lugs, and generator panel. Single and three phase options are available. The bus bars are tin plated copper and are shielded. Indoor and outdoors enclosures are an option. QO Load Centers enable the use of a full complement of accessories. This 1 phase load center has 3 spaces and 5 circuits. This system provides a 30A main breaker in a NEMA 1 enclosure. It also includes a ground bar, surface cover, and is UL rated. This product is for trailer use.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : UL Listed
    • Ambient Air Temperature For Operation : -5 °C || 40 °C
    • Nema Degree Of Protection : NEMA 1 indoor enclosure
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2212001
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : N/A
    • Take-Back : No
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 12.3430992857
  • Complementary
    • Height : 236 mm
    • Phase : 1 phase 2 wires
    • Tightening Torque : Cover 20 lb.in
    • Electrical Connection : lugs
    • Number Of Circuits : 5
    • Number Of Spaces : 3
    • Net Weight : 9.000 kg
    • Short-Circuit Current : 10 kA
    • Number Of Tandem Circuit Breakers : 2
    • Material : tin plated aluminium: busbar
    • Surface Finish : baked enamel Gray
    • Line Rated Current : 30 A
    • Enclosure Material : welded sheet steel
    • Awg Gauge : AWG 14...AWG 8 aluminium/copper
    • Width : 122 mm
    • Depth : 80 mm
    • Load Center Type : main breaker
    • Device Composition : grounding bar (factory installed)
    • Box Number : 3
  • Specifications
    • Country of Origin : Mexico
    • Width : 122 mm
    • Height : 236 mm
    • Weight : 9.000 kg
    • Range Of Product : QO
    • Product Or Component Type : Load Center
    • Cover Type : surface cover