SQUARE D

Motor circuit protector, PowerPacT J, 250A, 3 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, ABC

MOTOR CIRCUIT PROTECTOR 600V

SQDJJA36250M75 JJA36250M75 SQDJJA36250M75
1602.99 / EA
http://schema.org/OutOfStock
  • Depth: 86 mm
  • Height: 191 mm, 4.5 in
  • Length: 25 mm
  • Net Weight: 2.4 kg
  • Warranty Length: 18 mth
  • Weight: 2.4 kg
  • Width: 104 mm
PowerPacT J-Frame motor circuit protectors (MCP) are instantaneous-trip circuit breakers designed to offer short circuit protection for motors. The unique design of the PowerPacT MCPs accommodates transient motor inrush current without nuisance tripping. These motor protectors accept the same accessories and terminals as the PowerPacT J circuit breakers. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 250A, 3 pole, motor protector has a breaking capacity of 25kA at 600VAC. The breaker has a continuous current rating of 80%. PowerPacT J motor circuit protectors comply to UL, CSA, and IEC standards and are CE marked.
QTY
  • Product Description
  • Features
  • Specifications
PowerPacT J-Frame motor circuit protectors (MCP) are instantaneous-trip circuit breakers designed to offer short circuit protection for motors. The unique design of the PowerPacT MCPs accommodates transient motor inrush current without nuisance tripping. These motor protectors accept the same accessories and terminals as the PowerPacT J circuit breakers. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 250A, 3 pole, motor protector has a breaking capacity of 25kA at 600VAC. The breaker has a continuous current rating of 80%. PowerPacT J motor circuit protectors comply to UL, CSA, and IEC standards and are CE marked.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Ambient Air Temperature For Operation : -25-70 °C
    • Standards : UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
    • Product Certifications : UL || CSA || NOM
    • Ip Degree Of Protection : front cover IP40
    • Pollution Degree : 3 IEC 60947-1
    • Ambient Air Temperature For Storage : -50-85 °C
    • Quality Labels : CE
    • Operating Altitude : < 6561.68 ft (2000 m) without derating || 5000 m with derating
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2206031EN
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Removable Battery : No
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : ENVEOLI2206031EN
    • Take-Back : No
    • Pvc Free : Yes
    • Global Warming ; Total Life Cycle​ : 1 165 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 1164.93500923
  • Complementary
    • Mounting Mode : I-Line bracket)
    • Network Frequency : 50/60 Hz
    • Terminal Identifier : AL250JD
    • [Ics] Rated Service Breaking Capacity : 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
    • [Ith] Conventional Free Air Thermal Current : 117-217 A
    • Trip Unit Technology : thermal-magnetic
    • Height : 191 mm
    • [Ue] Rated Operational Voltage : 600 V AC 50/60 Hz IEC 60947-3
    • Tightening Torque : 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
    • Mounting Support : bracket
    • Breaking Capacity Code : J
    • Magnetic Tripping Current : 2500-2500 A
    • Local Signalling : switched off (OFF) 1 trip indicator green)
    • Number Of Slots : 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
    • Electrical Connection : I-Line connection, line || lugs, load
    • Mounting Height : 4.5 in
    • Net Weight : 2.4 kg
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • Magnetic Hold Current : 1250 A
    • Control Type : toggle
    • Circuit Breaker Application : HACR rated
    • Wire Stripping Length : 25 mm
    • Line Rated Current : 250-250 A
    • Utilisation Category : category A
    • Long Time Pick-Up Adjustment Range : 0.25...1 x In
    • Continuous Current Rating : 80 %
    • Breaking Capacity : 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
    • [Ui] Rated Insulation Voltage : 750 V IEC 60947-2
    • Suitability For Isolation : yes IEC 60947-2
    • Communication Interface : Modbus || Ethernet
    • Poles Description : 3P
    • Protection Type : overload protection || short-circuit protection
    • Awg Gauge : AWG 3/0...350 kcmil aluminium/copper terminals
    • Width : 104 mm
    • Depth : 86 mm
  • Specifications
    • Country of Origin : Mexico
    • Length : 25 mm
    • Width : 104 mm
    • Height : 4.5 in
    • Weight : 2.4 kg
    • Product Or Component Type : circuit breaker
    • Product Name : PowerPact J
    • Range : PowerPact
    • Device Application : distribution