SQUARE D

Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 18kA, lugs, Micrologic 6.0P, 100%, modbus

MOLDED CASE CIRCUIT BREAKER 60

SQDPGL36080CU64AE1 PGL36080CU64AE1 785901974277
27948.41 / EA
http://schema.org/OutOfStock
  • Certifications: CSA, NOM, UL
  • Depth: 8.05 in
  • Height: 12.86 in
  • Line Rated Current: 800-800 A
  • Net Weight: 32 lb
  • Standard: CSA, IEC 60947-2, NEMA, NOM-003-SCFI-2000, UL
  • Storage Temperature: -50-85 °C
  • Strip Length: 25 mm
  • Warranty Length: 18 mth
  • Width: 8.27 in
This PowerPact P, circuit breaker has a rated currrent of 800A and a rated operational current of 600VAC with a breaking capacity of 18 kA@600VAC. This unit mounted breaker is a 3-pole and has a continuous current rating of 100 %. This breaker has an electronic trip unit technology and a Micrologic 6.0 P trip unit. Dimensions for this product are 12.86 in (H), 8.05 in (W), 8.27 in (D). This product comes with an 18 month warranty.
QTY
  • Product Description
  • Specifications
This PowerPact P, circuit breaker has a rated currrent of 800A and a rated operational current of 600VAC with a breaking capacity of 18 kA@600VAC. This unit mounted breaker is a 3-pole and has a continuous current rating of 100 %. This breaker has an electronic trip unit technology and a Micrologic 6.0 P trip unit. Dimensions for this product are 12.86 in (H), 8.05 in (W), 8.27 in (D). This product comes with an 18 month warranty.
  • Specifications
    • Product Or Component Type : circuit breaker
    • Product Name : PowerPact P
    • Device Application : distribution
    • Range : PowerPact
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Network Frequency : 50/60 Hz
    • Wire Stripping Length : 25 mm
    • Terminal Identifier : AL800M23K
    • Line Rated Current : 800-800 A
    • [Ics] Rated Service Breaking Capacity : 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • Long Time Pick-Up Adjustment Range : 0.4...1 x Ir
    • Trip Unit Technology : electronic, power, Micrologic 6.0 P, LSI
    • Trip Unit Name : Micrologic 6.0 P
    • Height : 12.86 in
    • Continuous Current Rating : 100 %
    • Breaking Capacity : AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • [Ui] Rated Insulation Voltage : 750 V IEC 60947-2
    • Communication Interface : Modbus
    • [Ue] Rated Operational Voltage : 600 V AC 50/60 Hz UL 489
    • Tightening Torque : 50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil) || 1.0-1.3 N.m
    • Breaking Capacity Code : G
    • Accessory / Separate Part Type : Modbus connecting cable
    • Poles Description : 3P
    • Local Signalling : overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
    • Quantity Per Set : 1
    • Number Of Slots : 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
    • Awg Gauge : 3 x AWG 3/0...3 x 500 kcmil aluminium/copper
    • Width : 8.27 in
    • Electrical Connection : lugs load || lugs line
    • Depth : 8.05 in
    • Net Weight : 32 lb(US)
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • Control Type : toggle
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : ENVEOLI1407012EN
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1407012EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Eu Rohs Directive : Compliant
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Ambient Air Temperature For Operation : -2-70 °C
    • Pollution Degree : 3 IEC 60947-1
    • Ambient Air Temperature For Storage : -50-85 °C
    • Standards : UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
    • Quality Labels : CE
    • Product Certifications : UL || CSA || NOM
    • Operating Altitude : < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
    • Ip Degree Of Protection : front cover IP40