Automatic switch, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, magnetic

Automatic switch, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, magnetic

SQDRKF36000S16 RKF36000S16 785901816515
23424.32 / EACH
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 14.49 in
  • Height: 16.24 in
  • Warranty Length: 18 mth
  • Width: 16.54 in
The PowerPact M-frame, P-frame, and R-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. These breakers are available with Micrologic electronic trip units.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : UL Listed || CSA || IEC
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2206034_V2
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Removable Battery : Yes
    • Circularity Profile : ENVEOLI2206034_V2
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 2439.5085845081917
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 153.97247060998086
    • Carbon Footprint Of The Distribution Phase [A4] : 10 kg CO2 eq.
    • Pvc Free : Yes
    • Carbon Footprint Of The Installation Phase [A5] : 7 kg CO2 eq.
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 2 653 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 42.859923332418305
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 2652.724519014039
  • Complementary
    • Height : 16.24 in
    • Tightening Torque : 68-68 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 68-68 N.m 50-150 mm² (AWG 1/0...300 kcmil)
    • Breaking Capacity Code : K
    • Magnetic Tripping Current : 57000-57000 A
    • Electrical Connection : busbar connection, line || busbar connection, load
    • Mounting Mode : unit mount
    • Short-Circuit Withstand : 65 kA 240 V UL 489 || 65 kA 480 V UL 489 || 65 kA 600 V UL 489
    • Poles Description : 3P
    • Line Rated Current : 1600 A
    • Width : 16.54 in
    • Depth : 14.49 in
    • [Ue] Rated Operational Voltage : 600 V AC
  • Specifications
    • Country of Origin : United States
    • Width : 16.54 in
    • Height : 16.24 in
    • Range Of Product : PowerPact R
    • Circuit Breaker Type : R-Frame
    • Product Or Component Type : automatic switch
    • Trip Unit Technology : magnetic