Mini circuit breaker, E-Frame, 100A, 3 pole, 480Y/277 VAC, 65 kA max, bolt on, aux switch, alarm switch

MINI CIRCUIT BREAKER, E-FRAME,

SQDEGB34100AABA SQDEGB34100AABA
0.00 / EA
http://schema.org/OutOfStock
  • Certifications: CULus
  • Depth: 4.05 in
  • Height: 5.66 in
  • Line Rated Current: 100 A
  • Mounting Type: Bolt-On
  • Net Weight: 4 lb
  • Number of Poles: 3
  • Width: 3.92 in
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 100A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes an auxiliary switch and an alarm switch. This breaker was calibrated for 40 degrees C. HACR rated.
QTY
  • Product Description
  • Specifications
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 100A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes an auxiliary switch and an alarm switch. This breaker was calibrated for 40 degrees C. HACR rated.
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant with Exemptions
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
  • Complementary
    • Circuit Breaker Application : HACR rated
    • Height : 5.66 in
    • Mounting Mode : bolt-on
    • Holding Current : 1000 A
    • Tightening Torque : 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
    • Breaking Capacity Code : G
    • Product Destination : NF panelboard
    • Electrical Connection : lugs aluminium
    • Number Of Spaces Required : 4
    • Line Rated Current : 100 A
    • Protection Type : overload || short-circuit
    • Local Signalling : trip indicator
    • Awg Gauge : AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
    • Width : 3.92 in
    • Depth : 4.05 in
    • Number Of Spaces : 4
    • Device Composition : alarm switch || auxiliary switch
    • Breaking Capacity : 35 kA 277 V AC || 65 kA 240 V AC || 35 kA 480Y/277 V AC || 65 kA 120 V AC || 65 kA 120/240 V AC
    • Net Weight : 4 lb(US)
    • Trip Unit Technology : thermal-magnetic
    • Number Of Poles : 3
    • [Ue] Rated Operational Voltage : 480Y/277 V AC
  • Specifications
    • Module Type : E-Frame
    • Range Of Product : 125 A Frame EDB-EGB-EJB
    • Trip Unit Rating : 2300-2300 A
    • Product Or Component Type : miniature circuit-breaker
    • Device Short Name : EGB
  • Environment
    • Product Certifications : cULus
    • Ambient Air Temperature For Operation : 40 °C