SQUARE D

Plug-in unit, I-Line Busway, M-frame, 800A, 3 phase, 4 wire, 600VAC, 25kA, ground, neutral, vertical

BUSWAY I-LINE CIRCUIT BREAKER

SQDPTMJ36800GNV PTMJ36800GNV SQDPTMJ36800GNV
0.00 / EA
http://schema.org/OutOfStock
I-Line Busway offers a complete line of compatible, sandwich-type feeder and plug-in busway lengths, fittings, and plug-in units. I-Line plug-in busway has options to 1600A for circuit breaker plug-ins and 1200A for fusible plug-ins. Circuit breaker and fusible plug in units are available in 3 phase, 3 wire or 3 phase, 4 wire configurations. This circuit breaker plug-in unit is 800A, 600VAC, 3 phase, 4 wire with M-frame breaker. Its circuit breaker has a 25kA interrupting trip rating. This unit includes a ground and neutral and is vertical mount. I-Line Busway plug in units are UL listed and CSA certified.
QTY
  • Product Description
  • Specifications
I-Line Busway offers a complete line of compatible, sandwich-type feeder and plug-in busway lengths, fittings, and plug-in units. I-Line plug-in busway has options to 1600A for circuit breaker plug-ins and 1200A for fusible plug-ins. Circuit breaker and fusible plug in units are available in 3 phase, 3 wire or 3 phase, 4 wire configurations. This circuit breaker plug-in unit is 800A, 600VAC, 3 phase, 4 wire with M-frame breaker. Its circuit breaker has a 25kA interrupting trip rating. This unit includes a ground and neutral and is vertical mount. I-Line Busway plug in units are UL listed and CSA certified.
  • Environment
    • Product Certifications : UL listed file E22182 || CSA C22.2 No 27
    • Standards : UL 857
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1410002EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : "WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : N/A
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Height : 615 mm
    • Condition Of Use : vertical installation
    • Phase : 3 phase
    • Line Rated Current : 800-800 A
    • Mounting Mode : bolt-on
    • Poles Description : 3P
    • Protection Type : circuit breaker
    • Width : 1275 mm
    • Wiring Configuration : 4-wire (integral ground bus)
    • Depth : 631 mm
    • [Ue] Rated Operational Voltage : 600 V AC
    • Awg Gauge : AWG 3/0...500 kcmil 3 phase and neutral || AWG 6...300 kcmil 4 ground
    • Breaking Capacity : 100 kA 240 V AC || 65 kA 480 V AC || 25 kA 600 V AC
    • [Ics] Rated Service Short-Circuit Breaking Capacity : 80 %
  • Specifications
    • Width : 1275 mm
    • Height : 615 mm
    • Trip Unit Technology : electronic, basic, ET 1.0, LI
    • Range Of Product : I-Line
    • Circuit Breaker Type : M-frame
    • Product Or Component Type : plug-in unit