100 A Load Center with Two T104M Mechanisms, 8-Breaker Spaces

125A POOL CNTRL CTR

INTT30404R T30404R 078275124318
404.21 / Each
http://schema.org/OutOfStock
  • Applications: Distribution/Control Panel, Motor Control, Pump Control
  • Country of Origin: Mexico
  • Depth: 120.7 mm, 4.75 in
  • Height: 16.875 in, 428.6 mm
  • Material: Metal
  • Max. Operating Temperature: 130 °F, 54 °C
  • Min. Operating Temperature: -40 °C, -40 °F
  • Number of Circuits: 2
  • Power Consumption: 3 W
  • Switch Type: DPST/DPST
  • Warranty Length: 1 yr
Can be used as a load center only, or add mechanisms or wiring devices for complete control systems.
QTY
  • Product Description
  • Features
  • Specifications
Can be used as a load center only, or add mechanisms or wiring devices for complete control systems.
  • Features
    • Eight breaker spaces
    • Reduces installation costs
    • Eliminates the need for additional service panels
    • Fits most of our hard-wired T100 mechanical and PE digital timers
    • Control two-speed pumps with the T30604R
    • Fully compatible with all electrical requirements for pool/spa installations
    • Load center dead front has two knockouts and one on the side for switches or GFCIs
    • Wiring devices may be installed in these load centers with the use of Standoffs, sold separately
  • Prop 65
    • Please see the Warning @ www.P65Warnings.ca.gov - Lead
  • Specifications
    • Country of Origin : Mexico
    • Product Height : 16.875 in; 428.6 mm
    • Product Depth : 4.75 in; 120.7 mm
    • Operating Temperature Min : -40°F; -40°C
    • Operating Temperature Max : 130°F; 54°C
    • Warranty Period : 1-Year limited
    • Color : Beige
    • Applications : Distribution/Control Panel; Motor Control; Pump Control
    • Number Of Breaker Knockouts : 8
    • Number Of Circuits : 2
    • Enclosure Type : 3R Beige metal
    • Switch Type : DPST/DPST
    • Power Consumption Max W : 3 W
    • Load Center Ratings : 100 A, 120 VAC, 60 Hz; 100 A, 208 VAC, 60 Hz; 100 A, 240 VAC, 60 Hz, Single Phase
    • Pilot Duty Load Ratings Ranges : 1000 VA, 120-240 VAC, 60 Hz
    • Load Center Rating Display : 100 A, 120-240 VAC, Single Phase, 60 Hz
    • Mechanism Supply Voltage : 240/240 VAC, 60 Hz
    • Mechanisms : (2) T104M
    • PDF Standards And Certifications : cCSAus
    • Material : Metal
  • Load Ratings
    • Pilot Duty Load Ratings : 1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz
    • Tungsten Load Ratings : 40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz
    • Tungsten Load Ratings Ranges : 40 A, 120-240 VAC, 60 Hz
    • Resistive Load Ratings : 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
    • Resistive Load Ratings Ranges : 40 A, 120-240 VAC, 60 Hz
    • Inductive Load Ratings : 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
    • Inductive Load Ratings Ranges : 40 A, 120-240 VAC, 60 Hz
    • Motor Load Ratings Ranges : 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
  • Knockout
    • Knockout Dimensions Bottom : (4) 1/2" - 3/4", (3) 1/2", (2) 3/4" - 1"
    • Knockout Dimensions Back : (5) 1/2" - 3/4"
    • Knockout Dimensions Left : (1) 3/4" - 1"
    • Knockout Dimensions Right : (1) 1 3/4" x 2 3/4"
    • Number Of Receptacle Switch Knockouts : 2
  • Certifications
    • CSA Certification : cCSAus