Photoelectric sensors XU, XUY, ampli for fibre, 24 VDC

PHOTOELECTRIC SENSORS XU, XUY,

SQDXUYAFVDO2946S XUYAFVDO2946S 3389119019811
246.75 / EA
http://schema.org/OutOfStock
  • Certifications: CE, CULus
  • Current: 120 mA
  • Enclosure Material: Polycarbonate
  • Material: Plastic
  • Operating Temperature: 0-40 °C
  • Storage Temperature: -20-60 °C
QTY
  • Specifications
  • Specifications
    • Series Name : Application
    • Specific Application Of Photoelectric Detector : detection of little marks and coloured tags || sorting out of coloured parts || detection of translucent coloured parts || quality control of lids colour or presence of labels || detection of coloured wires || detection of one to four colours
    • Range Of Product : Telemecanique Photoelectric sensors XU
    • Sensor Design : fiber design
    • Sensor Name : XUY
  • Complementary
    • Current Consumption : 120 mA no-load
    • Type Of Output Signal : discrete
    • Setting-Up : sensitivity adjustment with teach mode
    • Supply Voltage Limits : 21.6-26.4 V DC
    • Maximum Voltage Drop : <2.2 V 100 mA || <0.5 V 10 mA
    • Switching Capacity In Ma : 100 mA overload and short-circuit protection)
    • Enclosure Material : polycarbonate strong housing
    • Supply Circuit Type : DC
    • Electronic Sensor Type : photo-electric sensor
    • Maximum Delay Recovery : 1 ms XUYFPCF. || 20 ms XUYFPCP.
    • Maximum Delay Response : 1 ms XUYFPCF. || 20 ms XUYFPCP.
    • Material : plastic
    • Voltage State 0 Guaranteed : < 1.4 V
    • [Us] Rated Supply Voltage : 24 V DC reverse polarity protection
    • Switching Frequency : 25 Hz || 500 Hz
    • Voltage State 1 Guaranteed : > 3 V
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CE || cULus
    • Ambient Air Temperature For Operation : 0-40 °C
    • Ambient Air Temperature For Storage : -20-60 °C
    • Ip Degree Of Protection : IP65
    • Immunity To Ambient Light : 3000 lux incandescent bulb || 5000 lux natural light