single function relay, Harmony Timer Relays, 5A, 4CO, 0.1s..100h, on delay, 230V AC

TIMER 250VAC 3A REXL +OPTIONS

SQDREXL4TMP7 REXL4TMP7 3389119400107
73.99 / EA
http://schema.org/OutOfStock
  • Certifications: CUL, UL
  • Line Rated Current: 5 A
  • Net Weight: 0.05 kg
  • Standard: 73/23/EEC, 89/336/EEC, 93/68/EEC, EN 50081-2, IEC 60601-1, IEC 60601-2, IEC 61000-6-2, IEC 61812-1
  • Storage Temperature: -40-70 °C
  • Warranty Length: 18 mth
This Harmony REXL timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 5A, is 48mm wide and can be supplied with 230V AC. It is a plug-in device, meaning it is quick and easy to install with the need for tools. It also offers a sealable cover, simple and precise settings with rotary trimmers. It is designed for socket plug in, this allows quick and easy installation and minimizes set up and repair time. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. 0 0 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Specifications
This Harmony REXL timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 5A, is 48mm wide and can be supplied with 230V AC. It is a plug-in device, meaning it is quick and easy to install with the need for tools. It also offers a sealable cover, simple and precise settings with rotary trimmers. It is designed for socket plug in, this allows quick and easy installation and minimizes set up and repair time. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. 0 0 0 0 0 0 0 0 0 0 0 0 0 0
  • Environment
    • Product Certifications : cUL || UL
    • Ambient Air Temperature For Operation : -20-60 °C
    • Resistance To Electromagnetic Fields : 10 V/m IEC 61000-4-3 level 3
    • Standards : IEC 61000-6-2 || EN 50081-2 || IEC 60601-1 || IEC 60601-2 || 73/23/EEC || 93/68/EEC || 89/336/EEC || IEC 61812-1
    • Disturbance Radiated/Conducted : class B EN 55022 (EN 55011 group 1)
    • Immunity To Microbreaks : 5 ms
    • Immunity To Voltage Dips : >= 95 % / 1 s IEC 61000-4-11 || 30 % / 10 ms IEC 61000-4-11 || 60 % / 100 ms IEC 61000-4-11
    • Vibration Resistance : 0.35 mm 10-55 Hz)IEC 60068-2-6
    • Ip Degree Of Protection : IP50 conforming to IEC 60529
    • Ambient Air Temperature For Storage : -40-70 °C
    • Relative Humidity : 95-95 % without condensation IEC 60068-2-6
    • Resistance To Electrostatic Discharge : 6 kV in contact IEC 61000-4-2 level 3 || 8 kV in air IEC 61000-4-2 level 3
    • Immunity To Radioelectric Fields : 10 V 0.15...80 MHz)IEC 61000-4-6 level 3
    • Dielectric Strength : 2 kV 1 mA/1 minute 50 Hz IEC 60601-1 || 2 kV 1 mA/1 minute 50 Hz IEC 61812-1
    • Resistance To Fast Transients : 2 kV IEC 61000-4-4 level 3
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1310019EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • China Rohs Regulation : X
    • Circularity Profile : N/A
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • Setting Accuracy Of Time Delay : 10 % at full scale 25 °C IEC 61812-1
    • Line Rated Current : 5 A AC
    • Creepage Distance : 4 kV/3 IEC 60664-1
    • Repeat Accuracy : +/- 0.5 %
    • Contacts Material : cadmium free
    • Output Overvoltage Protection : 2 J
    • Voltage Range : 0.85...1.15 Us
    • Electrical Durability : 100000 cycles 250 V AC resistive
    • Net Weight : 0.05 kg
    • Voltage Drift : +/- 0.2 %/V
    • Reset Time : 250 ms after time delay, on de-energisation || 50 ms during time delay, on de-energisation
    • Power Consumption In Va : 3 VA
    • [Us] Rated Supply Voltage : 230 V AC 50/60 Hz
    • Temperature Drift : 0.05 %/°C
    • Surge Withstand : 2 kV IEC 61000-4-5 level 3
    • [Ui] Rated Insulation Voltage : 250 V IEC 255 Group C || 250 V VDE 0010
    • Minimum Switching Current : 100 mA
    • Temporary Permissible Current : 10 A < 10 s
    • Local Signalling : for output in operation 1 LED (red) || for power ON 1 LED (yellow)
    • Mechanical Durability : 10000000 cycles
    • Maximum Switching Capacity : 4 x 5 A
  • Specifications
    • Discrete Output Type : relay
    • Range Of Product : Harmony Timer Relays
    • Product Or Component Type : single function relay
    • Component Name : REXL
    • Fixing Mode : plug-in (socket)
    • Contacts Type And Composition : 4 C/O
    • Time Delay Range : 6...60 s || 1...10 s || 6...60 min || 1...10 min || 0.1...1 s || 10...100 h || 1...10 h
    • Time Delay Type : power on-delay