single function relay, Harmony Timer Relays, 8A, 1CO, 1s..100h, single interval relay, 24V DC or 24...240V AC DC

ONE SHOT TIMER TIMING ON IMPU

SQDRE17RBMU RE17RBMU 3606480552687
80.14 / EA
http://schema.org/OutOfStock
  • Depth: 72 mm
  • Dielectric Strength: 1 mA, 2.5 kV, 50 Hz
  • Input Voltage: 10 V
This Harmony RE17R timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 8A, is 17.5mm wide and can be supplied with 24V DC, 24V to 240V AC. It also has 1 changeover contact SPDT (single pole double throw). It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Multi function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RE17R timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 8A, is 17.5mm wide and can be supplied with 24V DC, 24V to 240V AC. It also has 1 changeover contact SPDT (single pole double throw). It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Multi function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0 0
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Impulse Duration : 100 ms with load in parallel typical, 30 ms typical
    • Maximum Switching Current : 8 A AC/DC
    • Maximum Switching Voltage : 250 V AC
    • Minimum Switching Current : 10 mA 5 V DC
    • Uc Control Circuit Voltage : 24 V, 24...240 V
    • Uimp Rated Impulse Withstand Voltage : 5 kV 1.2/50 µs
    • Us Rated Supply Voltage : 24...240 V AC 50/60 Hz, 24 V DC
    • Line Rated Current : 5 A
    • Maximum Delay Response : 100 ms
    • Maximum Power Consumption In W : 0.6 W 24 V DC
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Control Type : selector switch front panel, without test button, without test button
    • Dielectric Strength : 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
    • Electrical Durability : 100000 cycles resistive 8 A 250 V AC
    • Electromagnetic Compatibility : electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2, electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2, susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3, electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4, electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4, 1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5, 1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5, conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6, voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11, voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11, conducted and radiated emissionsclass B EN 55022
    • Function Available : B- Single interval relay w/ control signal-1 C/O
    • Insulation Resistance : 100 MOhm 500 V DC IEC 60664-1
    • Local Signalling : LED indicator on steady: relay energised, no timing in progress, LED indicator 80 % ON and 20 % OFF flashing: timing in progress, LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L)
    • Mounting Position : any position in relation to normal vertical mounting plane
    • Mounting Support : 35 mm DIN rail conforming to IEC 60715
    • Power Consumption In Va : 0-32 VA 240 V AC
    • Repeat Accuracy : +/- 0.5 % IEC 61812-1, +/- 0.5 % IEC 61812-1+/- 0.5 % IEC 61812-1, +/- 0.5 % IEC 61812-1
    • Reset Time : 120 ms on de-energisation typical
    • Safety Reliability Data : MTTFd = 296.8 years, B10d = 270000
    • Setting Accuracy Of Time Delay : +/- 10 % of full scale 25 °C IEC 61812-1, +/- 10 % of full scale 25 °C IEC 61812-1, +/- 10 % of full scale 25 °C IEC 61812-1+/- 10 % of full scale 25 °C IEC 61812-1, +/- 10 % of full scale 25 °C IEC 61812-1, +/- 10 % of full scale 25 °C IEC 61812-1
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27
    • Supply Frequency : 50...60 Hz +/- 5 %
    • Temperature Drift : +/- 0.05 %/°C, +/- 0.05 %/°C
    • Tightening Torque : 0.6-1 N.m IEC 60947-1
    • Time Delay Range : 10...100 h, 1...10 min, 6...60 min, 1...10 s, 6...60 s, 1...10 h, 0.1...1 s
    • Time Delay Type : interval - B- Single interval relay w/ control signal, B, interval
    • Vibration Resistance : 20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6
    • Voltage Drift : +/- 0.2 %/V, +/- 0.2 %/V
    • Connections Terminals : screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end, screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end, screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end, screw connectors
    • Carbon Footprint Of The Distribution Phase A4 : 0.06002881841570492, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.17936841389121552, 0.2 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0005717838897834867
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 1.5565700314205309
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 51 kg CO2 eq., 50.94880139552928
    • Contacts Composition : 1 C/O
    • Supply Voltage Num 3 : 24...240 V AC 50/60 Hz, 24 V DC
    • Certificate Agency : GL, cULus, CSA
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Weee Scope : Out
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI121113EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1243
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : RE17
    • Contacts Material : cadmium free
    • Contacts Type And Composition : 1 C/O
    • Creepage Distance : 4 kV/3 IEC 60664-1
    • Device Short Name : RE17R
    • Functionality : pulse signal
    • Housing Material : polycarbonate
    • Immunity To Microbreaks : 20 ms
    • Marking : CE
    • Mechanical Durability : 10000000 cycles
    • Number Of Functions : 1
    • On Load Factor : 100 %
    • Operating Rate In Hz : 10 Hz
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : modular timing relay
    • Range Of Product : Harmony Timer Relays
    • Returnability : Yes
    • Software Version : v6.2.5-6
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 53 kg CO2 eq.
    • Voltage Range : 0.85...1.1 Us
    • Warranty In Months : 18
    • Pep Code : ENVPEP1211017EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-10-30
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Harmony RE17 timing relay can be set between 0.1 seconds and 100 hours which has an output rating of 8A with 7.5mm wide and can be supplied with 24 V DC, 24 to 240 V AC. It also has 1 change over contact SPDT (single pole double throw). It has one of market slimmest form-factors which allowing for a flexible and easy installation on DIN rail using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers and product is adhering to international standards.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; High voltage; 2020; Indonesia, ID
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; Global, GLO
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 13
    • Offer Owner Code : 190786
    • Pn : 1
    • Height Nominal : 90 mm
    • Width Nominal : 17.5 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-60 °C, -20-60 °C
    • Ambient Air Temperature For Storage : -30-60 °C, -30-60 °C
    • Ip Degree Of Protection : IP20 IEC 60529 terminal block), IP40 IEC 60529 housing), IP50 IEC 60529 front panel)
    • Relative Humidity : 93-93 % without condensation IEC 60068-2-30
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 52.74534044314652
    • Circularity Profile : ENVEOLI121113EN
    • Environmental Disclosure : ENVPEP1211017EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1211017EN
    • Pep Verification Date : 2025-10-30
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : modular timing relay
    • Range Of Product : Harmony Timer Relays
  • ETIM
    • ETIM 8 : EC001439
    • ETIM 9 : EC001439
  • Output Attributes
    • Discrete Output Type : relay
    • Nominal Output Current : 8 A
    • Output Type : relay
  • Input Attributes
    • Input Voltage : 10 V
  • Specifications
    • Country of Origin : Brazil, France, Indonesia, United States
    • Depth : 72 mm