three phase relay, Harmony Solid State Relays, 25A, panel mount, zero voltage switching, thermal pad, input 90 to 280V AC, output 42 to 660V AC

HARMONY, SOLID STATE RELAY, 25

SQDSSP3A225P7T 3606480579967
177.25 / EA
http://schema.org/OutOfStock
  • Dielectric Strength: 4 kV
  • Output Voltage: ...660 V
This Harmony SSP solid state panel mount 3-phase relay is rated 25A, is controlled with a 180V to 280V AC input, has a rated load voltage of 48V to 530V AC with zero voltage switching, ideal for resistive loads. It has a visual indicator showing the status of its input and a alarm output enabling a quick response to unexpected events. It also has a test button for easy debugging, testing and commissioning. It is also silent and reliable thanks to the absence of moving contacts. 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
This Harmony SSP solid state panel mount 3-phase relay is rated 25A, is controlled with a 180V to 280V AC input, has a rated load voltage of 48V to 530V AC with zero voltage switching, ideal for resistive loads. It has a visual indicator showing the status of its input and a alarm output enabling a quick response to unexpected events. It also has a test button for easy debugging, testing and commissioning. It is also silent and reliable thanks to the absence of moving contacts. 0 0 0 0 0 0 0 0 0 0 0 0
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Horse Power Rating : 0.75 hp 40 °C 120 V AC, 1 hp 40 °C 240 V AC, 3 hp 40 °C 480 V AC, 5 hp 40 °C 600 V AC
    • Maximum I T For Fusing : 380 A².s for 10 ms at 50 Hz, 370 A².s for 8.3 ms at 60 Hz
    • Maximum Voltage Drop : <1.4 V on-state, <1.4 V on-state
    • UIMP Rated Impulse Withstand Voltage : 4 kV for input to case, 6 kV for input/output circuit, 6 kV for input/output to case
    • Maximum Leakage Current : 3 mA off-state
    • Maximum Switching Voltage : 9 V AC turn-off
    • Minimum Switching Voltage : 90 V AC turn-on
    • UC Control Circuit Voltage : 90...280 V AC 50/60 Hz
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Dielectric Strength : 4 kV AC for input/output, 4 kV AC for input or output to case
    • Electromagnetic Compatibility : electrostatic discharge 4 kV criteria B contact discharge conforming to IEC 61000-4-2, electrostatic discharge 8 kV criteria B air discharge conforming to IEC 61000-4-2, conducted RF disturbances 10 V, 0.15...80 MHz criteria A conforming to IEC 61000-4-6, radiated radio-frequency electromagnetic field immunity test 10 V/m, 80 MHz...1 GHz criteria A conforming to IEC 61000-4-3, surge immunity test 1 kV criteria B output ports line to line conforming to IEC 61000-4-5, surge immunity test 2 kV criteria B output ports line to earth conforming to IEC 61000-4-5, surge immunity test 1 kV criteria B input ports line to earth conforming to IEC 61000-4-5, electrical fast transient/burst immunity test 2 kV, 5kHz criteria B output ports conforming to IEC 61000-4-4, immunity to voltage dips 0 %/20 ms criteria B conforming to IEC 61000-4-11, immunity to voltage dips 40 %/200 ms criteria C conforming to IEC 61000-4-11, immunity to voltage dips 70 %/500 ms criteria C conforming to IEC 61000-4-11, immunity to short interruption 0 %/5 s criteria C conforming to IEC 61000-4-11, electrical fast transient/burst immunity test 1 kV, 5kHz criteria B input ports conforming to IEC 61000-4-4, radiated radio-frequency electromagnetic field immunity test 3 V/m, 1.4...6 GHz criteria A conforming to IEC 61000-4-3, radiated emission 30...1000 Mhz environment A conforming to IEC 60947-1, conducted emission 0.15...30 Mhz environment A conforming to IEC 60947-1
    • Insulation Resistance : >= 1000 MOhm at 500 V DC, >= 1000 MOhm at 500 V DC, >= 1000 MOhm at 500 V DC
    • Motor Power KW : 0.55 kW 40-40 °C 120 V AC, 0.75 kW 40-40 °C 240 V AC, 2.2 kW 40-40 °C 480 V AC, 3.7 kW 40-40 °C 600 V AC
    • Response Time : 20 ms (turn-on), 30 ms (turn-off)
    • Tightening Torque : 1.2 N.m for input, 2.5 N.m for output
    • Carbon Footprint Of The Distribution Phase A4 : 0.0352229348, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.1 kg CO2 eq., 0.0587759289
    • Carbon Footprint Of The Installation Phase A5 : 0.002245978, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 1 kg CO2 eq., 1.4393871047
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 2 899 kg CO2 eq., 2898.6994949433
    • Connections Terminals : screw terminals 1 x 0.2...1 x 2.5 mm², AWG 24...AWG 14) input, screw terminals 1 x 1.5...1 x 10 mm², AWG 16...AWG 8) output
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Legacy WEEE Scope : Out
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • COS PHI : 0.5-0.5 (with maximum load)
    • Device Short Name : SSP
    • DV DT : 500 V/µs off-state at maximum voltage
    • Flame Retardance : V0 conforming to UL 94
    • Local Signalling : LED, green input
    • Package Weight Lbs : 375.000 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : panel mount relay
    • Protection Device Type : TVS
    • Range Of Product : Harmony Solid State Relays
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Thermal Resistance : 0.24 °C/W
    • Total Lifecycle Carbon Footprint : 2 900 kg CO2 eq.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1307070_V2
    • Pep Verification Date : 2017-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : To control a circuit by a low-power signal with complete electrical isolation between control and controlled circuits, or where several circuits must be controlled by one signal during 20 years with a 30% use rate, in compliance with French standards.
    • Functional Unit Unit : unité (unit)
    • Product Kit Identifier : N
    • Product Manager : LEK YEE ALEX THO
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Lead Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 2900.2351268897
    • Environmental Disclosure : ENVPEP1307070_V2
    • IP Degree Of Protection : IP20
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1307070_V2
    • Pep Verification Date : 2017-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : panel mount relay
    • Range Of Product : Harmony Solid State Relays
  • Output Attributes
    • Output Switching Mode : zero voltage switching
    • Output Voltage : 42...660 V AC
    • Solid State Output Type : zero voltage switching
  • Surge Protection And Filtering Attributes
    • Surge Current : 275 A 20 ms, 300 A 16.6 ms
  • Input Attributes
    • COS PHI : 0.5-0.5 (with maximum load)
    • Input Current Limits : 7-20 mA
  • Overview Attributes
    • Device Presentation : complete product