Power Relays, Harmony 9A, SPST-NO, 30A, flanged panel mount, sealed cover, 24V DC

ELECTROMECHNICAL POWER RELAYS,

SQD9AS3D24 9AS3D24 3606489915292
9.65 / EA
http://schema.org/OutOfStock
  • Country of Origin: China
This 9AS3D24 power relay belongs to the Schneider Electric Harmony electromechanical relays range. 9A power relay has a sealed cover and is flanged panel mounting. It’s a 30A, 1 NO contact configuration mechanical relay with nominal coil voltage of 24V DC and coil resistance It conforms to international standard and certifications.
QTY
  • Product Description
  • Features
  • Specifications
This 9AS3D24 power relay belongs to the Schneider Electric Harmony electromechanical relays range. 9A power relay has a sealed cover and is flanged panel mounting. It’s a 30A, 1 NO contact configuration mechanical relay with nominal coil voltage of 24V DC and coil resistance It conforms to international standard and certifications.
  • Connections Terminals
    • Faston terminals contact terminal AWG 12...AWG 10, connection size: 6.35 x 0.8 mm
    • Faston terminals coil terminal AWG 22...AWG 14, connection size: 4.8 x 0.5 mm
  • IE Rated Operational Current
    • 30 A at 240 V AC-1
    • 30 A at 28 V DC (on resistive load)
    • 24 A at 240 V AC (on resistive load)
    • 98 A at 120 V AC-8a (locked rotor)
    • 22 A at 120 V AC-8a (full load)
    • 10 A at 277 V AC-5a (ballast)
  • Mounting Support
    • panel flange
  • CAD
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=MCADID0005652_3D-simplified.stp
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-back.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-back.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-bottom.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-bottom.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-front.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-front.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-isometric.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-isometric.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-left.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-left.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-right.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-right.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-top.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005652_3D-CAD&p_File_name=mcadid0005652_3d-simplified_2D-top.dxf
  • Rated Power In HP
    • 1 hp at 125 V AC
    • 2 hp at 250 V AC
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0.0002499711
    • 0 kg CO2 eq.
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0 kg CO2 eq.
    • 0.0040203711
  • Maximum Switching Voltage
    • 277 V AC
    • 28 V DC
  • UC Control Circuit Voltage
    • 24 V DC
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 0.2 kg CO2 eq.
    • 0.1599092784
  • Electrical Durability
    • 100000 cycles, 30 A at 240 V, AC-1
    • 50000 cycles for resistive load, 30 A at 28 V, DC
    • 100000 cycles for resistive load, 24 A at 240 V, AC
    • 30000 cycles for full load, 22 A at 120 V, AC-8a
    • 1000 cycles for motor load
    • 6000 cycles for ballast load, 10 A at 277 V, AC-5a
  • Vibration Resistance
    • +/- 0.75 mm 10-55 Hz operating
    • +/- 0.75 mm 10-55 Hz not operating
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • Charge Point Operator
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • Electrician
    • System Integrator
    • IT Channel Partner
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 51 kg CO2 eq.
    • 51.19282
  • Persona Type Ids
    • BM9
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SC
    • SI
    • VR
  • Dielectric Strength
    • 2500 V AC between coil and contact
    • 1500 V between contacts with micro disconnection
  • Carbon Footprint Of The Distribution Phase A4
    • 0.0041287423
    • 0 kg CO2 eq.
  • Average Resistance
    • 660 Ohm at 23 °C +/- 10 %
  • Minimum Switching Capacity
    • 5 W at 1 A, 5 V DC
    • 12 VA at 1 A, 12 V AC
  • Rated Power In VA
    • 470 VA at 240 V on pilot duty
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Shock Resistance
    • 10 gn operating
    • 100 gn not operating
  • UIMP Rated Impulse Withstand Voltage
    • 4 kV 1.2/50 µs
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-18
    • Manufacturing Carbon Footprint : 0.1599092784
    • Distribution Carbon Footprint : 0.0041287423
    • Installation Carbon Footprint : 0.0002499711
    • Use Carbon Footprint : 51.19282
    • End Of Life Carbon Footprint : 0.0040203711
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2006003EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Conformity Date : 2036
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : Yes
    • China ROHS Label : 1
    • Phenolic Free Solution : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 4
    • Tier : 4
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Drop Out Voltage Threshold : >= 0.1 Uc
    • Package Weight Lbs : 31.751 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : power relay
    • Protection Category : RT III
    • Range Of Product : Harmony
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 51 kg CO2 eq.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 51.3611283629
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2006003EN
    • Pep Verification Date : 2020-07-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 32
    • Functional Unit Description : Relays are used when a low-power signal is needed in order to control a circuit, or when a number of circuits need to be controlled by one signal.This relay uses a physical moving part to connect contacts within the output component of the relay. The movement of this contact is generated using electromagnetic forces from the low-power input signal, allowing the completion of the circuit that contains the high-power signal.The Power Relays are provided with 9A to offer robust performance in applications such as HVAC,motor controls, and alarm systems during 20 years with a 10% use rate, Input voltage range from 12 to 240 Vac and from 5 to 110 Vdc.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : Unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 73.9344
    • Nbr Of Units In Pkg : 1
    • Warranty In Months : 18
    • Energy Model Manufacturing A1 A3 : Energy model used: China
    • Energy Model Installation A5 : Electricity mix; AC; 120V; US
    • Energy Model Use B6 : Electricity mix; AC; 120V; US
    • Energy Model End Of Life C1 C4 : Electricity mix; AC; 120V; US
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.0005055178
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.0005050144
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000000002
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000005031
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000001
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 624.9618365361
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 1.616742268
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 0.0580049485
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.0032406598
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 623.2518
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 0.0320486598
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.0000146014
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.0000013725
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.0000132289
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 4.4126273896
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 3.0050309278
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0000000123
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 1.3687148
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0388816495
    • Materials For Energy Recovery Kg Total Life Cycle : 0.0004826392
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0.0004826392
    • Materials For Recycling Kg Total Life Cycle : 0.0234616082
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.0031614021
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.0045954639
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.0157047423
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.0928137738
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.0023329485
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000003695
    • Net Use Of Fresh Water M3 Installation A5 : 0.0000000273
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.0904768
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.0000036285
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 7.9194682804
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.0919092784
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0001466887
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0000339299
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 7.827256
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0001223835
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.0000009522
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000000236
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000009284
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000002
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.0008643938
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0000587456
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0000001045
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000000067
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.0008053448
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000001923
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 650.3801955464
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 2.5087835052
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0582993814
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0032594639
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 647.77
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0398531959
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 691.9974917113
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 2.7277525773
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 0.0583769072
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.0032644948
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 689.1682
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 0.039897732
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 41.6075902751
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.2189690722
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0000777979
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0000050701
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 41.388494
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0000443348
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.2876618557
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.2876618557
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 650.0925254433
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 2.2211134021
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0582993814
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0032594639
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 647.77
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0398531959
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.0917608247
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.0917608247
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 41.5158294503
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.1272082474
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0000777979
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0000050701
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 41.388494
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0000443348
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.0011486186
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.0011486186
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 4419.2291117526
    • Air Pollution M3 Manufacturing A1 A3 : 71.3121649485
    • Air Pollution M3 Distribution A4 : 0.175628866
    • Air Pollution M3 Installation A5 : 0.0099694845
    • Air Pollution M3 Operational Energy Use B6 : 4347.444
    • Air Pollution M3 End Of Life C1 C4 : 0.2873484536
    • Water Pollution M3 Total Life Cycle : 2534.7817030928
    • Water Pollution M3 Manufacturing A1 A3 : 9.9967010309
    • Water Pollution M3 Distribution A4 : 0.6789608247
    • Water Pollution M3 Installation A5 : 0.0379092784
    • Water Pollution M3 Operational Energy Use B6 : 2523.7288
    • Water Pollution M3 End Of Life C1 C4 : 0.3393319588
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 0.0504206706
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.0079521607
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.013052797
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 0.0013773196
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.0000188511
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.0000010416
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 0.0490153
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.0000081583
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 51.3611283629
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 0.1599092784
    • Global Warming Kg Equivalent Co2 Distribution A4 : 0.0041287423
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.0002499711
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 51.19282
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.0040203711
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.0000989938
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.0000013452
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0.0000000778
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.007850888
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.0000008558
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.0001289897
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.0000043419
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0.0000002531
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.012916998
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.0000022143
  • General Attributes
    • Product Or Component Type : power relay
    • Range Of Product : Harmony
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=502826348&lang=en-us
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Lead Free : Yes
    • Mercury Free : Yes
    • Silicon Free : Yes
    • Carbon Footprint : 51.3611283629
    • Circularity Profile : ENVEOLI2006003EN
    • Environmental Disclosure : ENVPEP2006003EN
    • EU ROHS Directive : Compliant
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2006003EN
    • Pep Verification Date : 2020-07-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • Input Attributes
    • Input Current : 30 A
  • Specifications
    • Country of Origin : China