interface plug-in relay, Harmony electromechanical relays, 12A, 1CO, 120V AC

PLUG-IN RELAY 250VAC 12AMP RSB

SQDRSB1A120F7 RSB1A120F7 3389110257243
6.95 / EA
http://schema.org/OutOfStock
  • Country of Origin: Austria
  • Dielectric Strength: 1000 V, 2500 V, 5000 V
  • Net Weight: 0.014 kg
  • Operating Position: Any Position
  • Warranty Length: 18 mth
  • Weight: 0.014 kg
This Harmony RSB interfacing plug-in relay has a control coil voltage of 120V AC and has 1 changeover contact single pole double throw with a rating of 12A. It helps to reduce the size of enclosures and increases machine reliability, you can mount nearly everywhere. Plug in type allows easy installation and maintenance. The product is IP40 and has a transparent cover allowing operator to visually inspect the status of contacts. 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RSB interfacing plug-in relay has a control coil voltage of 120V AC and has 1 changeover contact single pole double throw with a rating of 12A. It helps to reduce the size of enclosures and increases machine reliability, you can mount nearly everywhere. Plug in type allows easy installation and maintenance. The product is IP40 and has a transparent cover allowing operator to visually inspect the status of contacts. 0 0 0 0 0 0 0 0 0 0 0 0
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : UL || CSA || EAC
    • Standards : IEC 61810-1 || CSA C22.2 No 14 || UL 508
    • Shock Resistance : 10 gn 11 ms) not operating IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27
    • Dielectric Strength : 1000 V AC between contacts || 2500 V AC between poles || 5000 V AC between coil and contact
    • Vibration Resistance : +/- 1 mm (f= 10-55 Hz) conforming to IEC 60068-2-6
    • Ambient Air Temperature For Operation : -40-70 °C AC)
    • Ip Degree Of Protection : IP40 conforming to IEC 60529
    • Ambient Air Temperature For Storage : -40-85 °C
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Mercury Free : Yes
    • Reach Free Of Svhc : Yes
    • Take-Back : No
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 0.1424805609
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 7 kg CO2 eq.
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 7.4759513873
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP2403026EN
    • Packaging Without Single Use Plastic : No
    • Toxic Heavy Metal Free : Yes
    • Scip Number : 45b41055-6c52-408d-9c0c-5c663b810f29
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Carbon Footprint Of The Installation Phase [A5] : 0.0001028528
    • Circularity Profile : N/A
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 7.3045550228
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 0 kg CO2 eq.
    • Carbon Footprint Of The Distribution Phase [A4] : 0 kg CO2 eq.
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • [Ue] Rated Operational Voltage : 96...180 V AC 50/60 Hz
    • Operating Rate : <= 600 cycles/hour under load || <= 18000 cycles/hour no-load
    • Protection Category : RT I
    • Test Levels : level A group mounting
    • Net Weight : 0.014 kg
    • [Uimp] Rated Impulse Withstand Voltage : 3.6 kV IEC 61000-4-5
    • Maximum Switching Voltage : 250 V DC IEC
    • Switching Voltage : 12 V
    • [Ie] Rated Operational Current : 12 A AC-1/DC-1) NO IEC || 6 A AC-1/DC-1) NC IEC
    • [Ui] Rated Insulation Voltage : 400 V IEC 60947
    • Minimum Switching Current : 10 mA
    • Operating Time : 20 ms operating || 20 ms reset
    • Minimum Switching Capacity : 120 mW 10 mA, 12 V
    • Presentation Of Legend : without
    • Maximum Switching Capacity : 3000 VA/336 W
    • Safety Reliability Data : B10d = 100000
    • Contacts Material : silver alloy (AgNi)
    • Shape Of Pin : flat (PCB type)
    • Average Resistance : 8360 Ohm AC 20 °C +/- 10 %
    • Device Presentation : complete product
    • Average Coil Consumption : 0.75 VA AC
    • Sale Per Indivisible Quantity : 10
    • Electrical Durability : 100000 cycles, 12 A at 250 V, AC-1 NO || 100000 cycles, 6 A at 250 V, AC-1 NC
    • Mechanical Durability : 10000000 cycles
    • Compatibility Code : RSB
    • Operating Position : any position
    • Load Current : 12 A 250 V AC || 12 A 28 V DC
    • Drop-Out Voltage Threshold : >= 0.15 Uc AC
  • Specifications
    • Country of Origin : Austria
    • Weight : 0.014 kg
    • [Uc] Control Circuit Voltage : 120 V AC 50/60 Hz
    • Product Or Component Type : plug-in relay
    • Status Led : without
    • Series Name : RSB series
    • Contacts Type And Composition : 1 C/O
    • [Ithe] Conventional Enclosed Thermal Current : 12 A -40-40 °C
    • Range Of Product : Harmony Electromechanical Relays
    • Control Type : without lockable test button