Schneider Electric at Mayer

modular smart relay, Zelio Logic SR2 SR3, 26 IO, 24V DC, clock, display, 10 relay outputs

ZELIO SR3 26 I-O 24VDC RELAY

SQDSR3B261BD SR3B261BD 3389110549980
588.56 / EA
http://schema.org/OutOfStock
  • Number of Outputs: 10 Relay
  • Warranty Length: 18 mth
This Zelio Logic SR3 compact smart relay / programmable controller uses a supply voltage of 24V direct current. It has 26 inputs / outputs with screw-clamp terminals. It has compact design, allowing installation on DIN rail. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. Its simple ladder programming makes it adapted for non-specialists.
QTY
  • Product Description
  • Features
  • Specifications
This Zelio Logic SR3 compact smart relay / programmable controller uses a supply voltage of 24V direct current. It has 26 inputs / outputs with screw-clamp terminals. It has compact design, allowing installation on DIN rail. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. Its simple ladder programming makes it adapted for non-specialists.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Supply Current : 190 mA without extension), 300 mA with extensions)
    • Maximum Altitude Transport : 3048 m
    • Maximum Permissible Voltage : 30 V analogue input circuit
    • Uimp Rated Impulse Withstand Voltage : 4 kV EN/IEC 60947-1 and EN/IEC 60664-1
    • Us Rated Supply Voltage : 24 V
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Clock Drift : 12 min/year 0-55 °C, 6 s/month 25-25 °C
    • Conversion Error : +/- 5 % 25 °C analogue input circuit, +/- 5 % 25 °C analogue input circuit, +/- 5 % 25 °C analogue input circuit, +/- 6.2 % 55 °C analogue input circuit, +/- 6.2 % 55 °C analogue input circuit, +/- 6.2 % 55 °C analogue input circuit, +/- 5 % 25 °C analogue input circuit, +/- 5 % 25 °C analogue input circuit, +/- 5 % 25 °C analogue input circuit, +/- 6.2 % 55 °C analogue input circuit, +/- 6.2 % 55 °C analogue input circuit
    • Current State 0 Guaranteed : <= 0.5 mA IB...IG used as discrete input circuit), <= 0.5 mA IB...IG used as discrete input circuit), <= 0.75 mA I1...IA and IH...IR discrete input circuit), <= 0.75 mA I1...IA and IH...IR discrete input circuit)<= 0.5 mA IB...IG used as discrete input circuit), <= 0.5 mA IB...IG used as discrete input circuit), <= 0.75 mA I1...IA and IH...IR discrete input circuit), <= 0.75 mA I1...IA and IH...IR discrete input circuit)
    • Current State 1 Guaranteed : >= 1.2 mA IB...IG used as discrete input circuit), >= 1.2 mA IB...IG used as discrete input circuit), >= 2.2 mA I1...IA and IH...IR discrete input circuit), >= 2.2 mA I1...IA and IH...IR discrete input circuit)>= 1.2 mA IB...IG used as discrete input circuit), >= 1.2 mA IB...IG used as discrete input circuit), >= 2.2 mA I1...IA and IH...IR discrete input circuit), >= 2.2 mA I1...IA and IH...IR discrete input circuit)
    • Electrical Durability : AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1, AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1, DC-12 500000 cycles 24 V, 1.5 A relay output IEC 60947-5-1, DC-13 500000 cycles 24 V, 0.6 A relay output IEC 60947-5-1
    • Environmental Characteristic : EMC directive conforming to IEC 61000-6-2, EMC directive conforming to IEC 61000-6-3, EMC directive conforming to IEC 61000-6-4, EMC directive conforming to IEC 61131-2 zone B, low voltage directive conforming to IEC 61131-2
    • Number Or Control Scheme Lines : 0-500 FBD, 0-240 ladder
    • Operating Rate In Hz : 0.1 Hz at Ie)relay output, 10 Hz no load)relay output
    • Power Dissipation In W : 10 W with extensions, 6 W without extension
    • Repeat Accuracy : +/- 2 % 55 °C analogue input circuit, +/- 2 % 55 °C analogue input circuit, +/- 2 % 55 °C analogue input circuit+/- 2 % 55 °C analogue input circuit, +/- 2 % 55 °C analogue input circuit, +/- 2 % 55 °C analogue input circuit
    • Response Time : 10 ms from state 0 to state 1)relay output, 5 ms from state 1 to state 0)relay output
    • Switching Capacity In Ma : >= 10 mA 12 V relay output), >= 10 mA 12 V relay output), >= 10 mA 12 V relay output)>= 10 mA 12 V relay output), >= 10 mA 12 V relay output), >= 10 mA 12 V relay output)
    • Temperature Probe Type : NTC 10k 25 °C, NTC 1000k 25 °C, KTY81 210/220/221/222/250, Pt 500
    • Voltage State 0 Guaranteed : <= 5 V I1...IA and IH...IR discrete input circuit, <= 5 V I1...IA and IH...IR discrete input circuit, <= 5 V IB...IG used as discrete input circuit, <= 5 V IB...IG used as discrete input circuit<= 5 V I1...IA and IH...IR discrete input circuit, <= 5 V I1...IA and IH...IR discrete input circuit, <= 5 V IB...IG used as discrete input circuit
    • Voltage State 1 Guaranteed : >= 15 V I1...IA and IH...IR discrete input circuit, >= 15 V I1...IA and IH...IR discrete input circuit, >= 15 V IB...IG used as discrete input circuit, >= 15 V IB...IG used as discrete input circuit>= 15 V I1...IA and IH...IR discrete input circuit, >= 15 V I1...IA and IH...IR discrete input circuit, >= 15 V IB...IG used as discrete input circuit
    • Connections Terminals : screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid, screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid, screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid, screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end
    • Carbon Footprint Of The Distribution Phase A4 : 0.7941290734453625, 0.8 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1.001736206909394, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.1 kg CO2 eq., 0.07517082377885803
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 49 kg CO2 eq., 49.00265589919458
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 202 kg CO2 eq., 201.7502153207909
    • Certificate Agency : GL, C-tick, CSA, UL, GOST
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : PLC System - PLC CPU
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI0604006EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1846
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Checks : program memory on each power up
    • Clock : with
    • Contacts Type And Composition : NO relay output
    • Conversion Time : smart relay cycle time analogue input circuit
    • Counting Frequency : 1 kHz discrete input
    • Cycle Time : 6-90 ms
    • Disturbance Radiated Conducted : class B EN 55022-11 group 1
    • Immunity To Microbreaks : 1 ms
    • Local Display : with
    • Lsb Value : 39 mV analogue input circuit
    • Mechanical Durability : 10000000 cycles relay output
    • Operating Distance : 10 m between stations, with screened cable (sensor not isolated) analogue input circuit
    • Overvoltage Category : III conforming to IEC 60664-1
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : modular smart relay
    • Range Of Product : Zelio Logic
    • Returnability : Yes
    • Reverse Polarity Protection : with
    • Software Version : v6.2.2
    • Supply Voltage Limits : 19.2-30 V
    • Sustainable Packaging : Yes
    • Tightening Torque : 0.5 N.m
    • Total Lifecycle Carbon Footprint : 253 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Warranty In Months : 18
    • Pep Code : ENVPEP0604006EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-11-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : referent product
    • Functional-unit Description : To provide automated control of simple systems from 10 to 40 I/O for 10 years 100% of the time.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 10
    • Energy Model - Manufacturing [A1-a3] : France, FR
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Offer Owner Code : 190786
    • Pn : 1
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2, -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2, -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2, -20-55 °C IEC 60068-2-1 and IEC 60068-2-2, -20-55 °C IEC 60068-2-1 and IEC 60068-2-2-20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2, -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2, -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2
    • Ambient Air Temperature For Storage : -40-70 °C, -40-70 °C
    • Ip Degree Of Protection : IP20 IEC 60529 terminal block), IP40 IEC 60529 front panel)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 252.62390732411907
    • Circularity Profile : ENVEOLI0604006EN
    • Environmental Disclosure : ENVPEP0604006EN
    • Eu Rohs Directive : Compliant By Exemption
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 95-95 % without condensation or dripping water
    • Pep Code : ENVPEP0604006EN
    • Pep Verification Date : 2024-11-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : modular smart relay
    • Range Of Product : Zelio Logic
  • ETIM
    • ETIM 8 : EC001417
    • ETIM 9 : EC001417
  • Output Attributes
    • Output Thermal Current : 5 A for 2 outputs relay output, 8 A for 8 outputs relay output
    • Output Voltage Limits : 24...250 V AC relay output), 5...30 V DC relay output)
    • Number Of Outputs : 10 relay
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Analogue Input Range : 0...10 V, 0...24 V
    • Input Impedance : 12 kOhm IB...IG used as analogue input circuit, 12 kOhm IB...IG used as discrete input circuit, 7.4 kOhm I1...IA and IH...IR discrete input circuit
    • Analogue Input Number : 6
    • Analogue Input Resolution : 8 bits
    • Analogue Input Type : common mode
    • Discrete Input Current : 4 mA
    • Discrete Input Number : 16 IEC 61131-2 Type 1
    • Discrete Input Type : resistive
    • Discrete Input Voltage : 24 V DC
    • Input Compatibility : 3-wire proximity sensors PNP discrete input
  • Specifications
    • Country of Origin : Brazil, France, United States