Control relay, TeSys K, 2 NO + 2 NC, lt or eq to 690V, 120VAC coil

SQD CA2KN22G7 CONTROL RELAY 60

SQDCA2KN22G7 CA2KN22G7 3389110120721
41.22 / EA
http://schema.org/OutOfStock
  • Certifications: CB Scheme, CCC, CE, CSA, EAC, UKCA, UL
  • Contact Configuration: 2 NO + 2 NC
  • Depth: 57 mm
  • Height: 58 mm
  • Net Weight: 0.18 kg
  • Standard: CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, GB/T 14048.4, JIS C8201-4-1, UL 60947-4-1
  • Storage Temperature: -50-80 °C
  • Warranty Length: 18 mth
  • Width: 45 mm
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 120V 50/60Hz AC control circuit, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -25/+50°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium product (RoHS/REACh).
QTY
  • Product Description
  • Specifications
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 120V 50/60Hz AC control circuit, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -25/+50°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium product (RoHS/REACh).
  • Environment
    • Product Certifications : CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
    • Ambient Air Temperature For Operation : -25-50 °C
    • Standards : EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
    • Flame Retardance : V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
    • Ambient Air Temperature For Storage : -50-80 °C
    • Protective Treatment : TC IEC 60068
    • Ip Degree Of Protection : IP2X
    • Operating Altitude : 6561.68 ft (2000 m) without derating
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1503003EN
    • Sustainable Offer Status : Green Premium product
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Circularity Profile : ENVEOLI1503003EN
    • Eu Rohs Directive : Compliant
  • Complementary
    • Minimum Switching Current : 5 mA
    • Height : 58 mm
    • Control Circuit Voltage Limits : drop-out: 0.2...0.75 Uc (at <50 °C) || operational: 0.8...1.15 Uc (at <50 °C)
    • Non Overlap Distance : 0.5 mm
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 50 °C)
    • Mounting Support : rail || plate
    • Immunity To Microbreaks : 2 ms
    • Insulation Resistance : > 10 MOhm
    • Irms Rated Making Capacity : 110 A IEC 60947
    • Associated Fuse Rating : 10 A gG conforming to IEC 60947 || 10 A gG conforming to VDE 0660
    • Net Weight : 0.18 kg
    • Inrush Power In Va : 30-30 VA (at 20 °C)
    • Connections - Terminals : screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible with cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-1.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible without cable end
    • Minimum Switching Voltage : 17 V
    • Maximum Operating Rate : 10000 cyc/h
    • Tightening Torque : 1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
    • Mechanical Durability : 10 Mcycles
    • Hold-In Power Consumption In Va : 4.5-4.5 VA (at 20 °C)
    • Operating Time : 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
    • Width : 45 mm
    • Depth : 57 mm
    • [Ui] Rated Insulation Voltage : 690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14
    • Heat Dissipation : 1.3-1.3 W
  • Specifications
    • [Ue] Rated Operational Voltage : <= 690 V <= 400 Hz
    • Control Circuit Type : AC 50/60 Hz
    • [Uc] Control Circuit Voltage : 120 V AC 50/60 Hz
    • Contactor Application : control circuit
    • Product Or Component Type : control relay
    • Product Name : TeSys CAK
    • Range : TeSys
    • Pole Contact Composition : 2 NO + 2 NC
    • Utilisation Category : DC-13 || AC-15
    • Device Short Name : CA2K