safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

SAFETY CONTROLLER XPS-MC - 24

SQDXPSMC16ZC XPSMC16ZC 3389119010252
2160.00 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 153 mm
  • Height: 151.5 mm
  • Net Weight: 0.82 kg
  • Warranty Length: 18 mth
  • Weight: 0.82 kg
  • Width: 74 mm
This product is part of the Preventa XPS MP, XPS MC, XPS MCM range, an offer of safety controllers. This safety controller provides 16 inputs and 32 LEDs for signalling. It is a safety controller with a power consumption of 12W, control circuit voltage of 28.8V and a rated supply voltage of 24V DC. Supported communication port protocols are Modbus with RJ45 port, CANopen with 9-way SUB-D male port. It is an IP20 rated product. Its dimensions are 74mm (Width) x 153mm (Depth) x 151.5mm (Height). It weighs 0.82kg. It is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN/ISO 13849-1 and SIL3 EN/IEC 61508. This product is certified by UL, CSA and TUV. It meets EN 574/ISO 13851, EN 1760-1/ISO 13856-1, EN/IEC 61496-1, EN/IEC 60204-1, EN/IEC 60947-5-1, EN 954-1/EN/ISO 13849-1 and IEC 61508 standards. Simple, it features redundancy principle micro-processor based technology to provide advanced functions, flexibility regarding the choice of safety function and more precise diagnostics are just some of its advantages. Safety controller XPS MC is configured with a simple software environment where functions are mapped to the various controller outputs according to the application requirements.
QTY
  • Product Description
  • Features
  • Specifications
This product is part of the Preventa XPS MP, XPS MC, XPS MCM range, an offer of safety controllers. This safety controller provides 16 inputs and 32 LEDs for signalling. It is a safety controller with a power consumption of 12W, control circuit voltage of 28.8V and a rated supply voltage of 24V DC. Supported communication port protocols are Modbus with RJ45 port, CANopen with 9-way SUB-D male port. It is an IP20 rated product. Its dimensions are 74mm (Width) x 153mm (Depth) x 151.5mm (Height). It weighs 0.82kg. It is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN/ISO 13849-1 and SIL3 EN/IEC 61508. This product is certified by UL, CSA and TUV. It meets EN 574/ISO 13851, EN 1760-1/ISO 13856-1, EN/IEC 61496-1, EN/IEC 60204-1, EN/IEC 60947-5-1, EN 954-1/EN/ISO 13849-1 and IEC 61508 standards. Simple, it features redundancy principle micro-processor based technology to provide advanced functions, flexibility regarding the choice of safety function and more precise diagnostics are just some of its advantages. Safety controller XPS MC is configured with a simple software environment where functions are mapped to the various controller outputs according to the application requirements.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Ambient Air Temperature For Operation : -10-55 °C
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Ambient Air Temperature For Storage : -25-85 °C
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1406025EN
    • Packaging Without Single Use Plastic : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI1406025EN
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 515.03
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 24.4786497656
    • Carbon Footprint Of The Distribution Phase [A4] : 0.2 kg CO2 eq.
    • Pvc Free : Yes
    • Carbon Footprint Of The Installation Phase [A5] : 0 kg CO2 eq.
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 540 kg CO2 eq.
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 0.7177012636
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 540.3903893588
  • Complementary
    • Height : 151.5 mm
    • [Ith] Conventional Free Air Thermal Current : 16 A relay output || 6.5 A static output circuit
    • Mounting Support : mounting plate
    • Output Thermal Current : 4 A for both outputs simultaneously || 6 A for 1 output and 2 A for the other relay output
    • Power Consumption In W : 12 W
    • Minimum Output Voltage : 17 V relay output
    • Response Time : configurable : 20 ms or 30 ms with software XPSMCWIN
    • Data Format : 1 start bit/8 data bits || 1 stop bit even or odd || 2 stop bits without parity || RTU (Remote Terminal Unit) mode
    • Minimum Output Current : 10 mA relay output
    • Associated Fuse Rating : 16 A gL power supply || 4 A gL relay output || 6 A fast blow relay output
    • [Uimp] Rated Impulse Withstand Voltage : 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
    • Net Weight : 0.82 kg
    • Output Type : 2 relays, 2 NO contacts (4 NO total) || solid state, 6, volt-free
    • [Ui] Rated Insulation Voltage : 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
    • Parity : even Modbus || no Modbus || odd Modbus
    • Exchange Size : 14 words
    • Supported Modbus Function : 01 8-bit output data/32-bit input data || 02 32-bit input data/8-bit output data || 03 information and errors
    • Method Of Access : slave
    • Local Signalling : 32 LEDs
    • Number Of Addresses : 1-127 CANopen || 1-247 Modbus
    • Maximum Line Resistance : 100 Ohm <2000 m
    • Input Protection Type : external fuse 16 A
    • Width : 74 mm
    • Depth : 153 mm
    • [Uc] Control Circuit Voltage : 28.8 V
    • Function Of Module : dynamic monitoring of hydraulic valves on linear presses || eccentric press || emergency stop monitoring, with or without time delay, 1 or 2-channel wiring || enabling switch monitoring, 2 or 3 contacts || foot switch monitoring || guard monitoring for injection presses and blowing machines || guard monitoring with 1 or 2 limit switches || hydraulic press || magnetic switch monitoring category 4 EN/IEC 61496 || monitoring safety stop at top dead centre on eccentric press category 3 EN 574/ISO 13851 || muting function of light curtains || position selector || safety mat monitoring || safety time delays || shaft/chain breaking monitor || zero speed detection || light curtain monitoring category 4 IEC 61496 || two-hand control category 3 EN 574/ISO 13851
    • Synchronisation Time Between Inputs : depending on configuration selected
    • Breaking Capacity : 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
  • Specifications
    • Country of Origin : France
    • Width : 74 mm
    • Height : 151.5 mm
    • Weight : 0.82 kg
    • Product Certifications : UL || TÜV || CSA
    • [Us] Rated Supply Voltage : 24 V DC - 20...20 %
    • Range Of Product : Preventa Safety automation
    • Standards : IEC 61496-1 || EN 574/ISO 13851 || EN 1760-1/ISO 13856-1 || IEC 61508 || EN 954-1/EN/ISO 13849-1 || IEC 60947-5-1 || IEC 60204-1
    • Number Of Inputs : 16
    • Product Or Component Type : configurable safety controller
    • Safety Module Name : XPSMC
    • Type Of Start : configurable
    • Communication Port Protocol : CANopen 1 SUB-D 9-pin male, serial link 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps || Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
    • Safety Use Category : category 4 maximum EN 954-1/EN/ISO 13849-1 || PLE maximum ISO 13849-1 || SIL 3 maximum IEC 61508
    • Safety Level : can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 || can reach SIL 3 IEC 61508