Analog isolated high level output module, Modicon X80, 4 HART outputs, 4 to 20mA, conformal coating

analog ouput module X80 - 4 ou

SQDBMEAHO0412C BMEAHO0412C 3606480927799
2440.79 / EA
http://schema.org/OutOfStock
This HART analog isolated output module is part of the Modicon X80 range, an offer of common input/output and communication modules, power supplies and racks for Modicon M340 and Modicon M580. This product is composed of 4 output channels. Thanks to a protective coating on its circuit board, this product can be used in harsh environments with a temperature range from -25°C to +60°C/-13°F to 140°F. Modicon X80 modules provide a single environment for the deployment of I/O modules in automation architectures by reducing spare parts inventory, maintenance and training costs. This product is IP20 rated and offers 848454 hours of MTBF. This analog module has a weight of 0.223kg and dimensions of 32x100x86mm. This module meets the needs of applications in Transportation, Water and Waste Water, Consumer Packaged Goods, Mining Minerals Metals, Power generation, Energies and Chemicals, and Data centers. This product is certified by CE, UL, CSA, RCM, EAC, UKCA, Merchant Navy and meets EN 61000-6-5, EN 61850-3 standards. This module is compatible with Modicon M340, M580 (Local or Remote I/O) PLCs with a 20-way caged, screw clamp, or spring-type removable terminal block. The product must be installed on the rack and fixed with 2 screws.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_3D-Simpl.stp, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2D-bottom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2d-bottom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2D-front.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2d-front.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2D-isom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2d-isom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2D-left.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2d-left.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2D-rear.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2d-rear.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2D-right.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2d-right.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2D-top.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412C_2d-top.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=BMEAHO0412C_3D-simpl&p_File_name=BMEAHO0412(C)_terminal_block_lable.dxf
  • Conformance Attributes
    • Product Certifications : CE, UL, CSA, RCM, EAC, Merchant Navy, ATEX zone 2/22, IECEx zone 2/22
    • Standards : IEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS E10, IEC 61000-6-5, interface type 1 and type 2, IEC 61850-3, location G, IEC 60079-0
  • Important Information Attributes
    • Persona Type Ids : EU, OM8, SI
    • Persona Type Names : End User, OEM - Control Panelbuilder, System Integrator
    • Electrical Connection : 20 ways terminal block, Telefast
    • Environmental Characteristic : gas resistant class Gx ISA S71.04, gas resistant class 3C4 IEC 60721-3-3, dust resistant class 3S4 IEC 60721-3-3, sand resistant class 3S4 IEC 60721-3-3, salt resistant level 2 IEC 68252, mold growth resistant class 3B2 IEC 60721-3-3, fungal spore resistant class 3B2 IEC 60721-3-3, hazardous location class I division 2
    • Isolation Voltage : 1000 V DC 60 s between channels, 1400 V DC 60 s between channels and ground, 1400 V DC 60 s between channels and bus
    • Load Impedance Ohmic : 600 Ohm 0...20 mA, 570 Ohm 0...21 mA
    • Measurement Error : 0.1 % of full scale 25 °C, 0.45 % of full scale - 25...60 °C
    • Carbon Footprint Of The Distribution Phase A4 : 0.0295525818, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.4 kg CO2 eq., 0.4010198788
    • Carbon Footprint Of The Installation Phase A5 : 0.0601790061, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 29 kg CO2 eq., 28.8759515152
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 233 kg CO2 eq., 233.4714871508
    • Medium Desc : Analog isolated high level output module, Modicon X80, 4 HART outputs, 4 to 20mA, conformal coating
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-10
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : Out
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2311046EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • With Recycled Cardboard : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Application Specific I O : HART
    • Checks : broken wire detection
    • Function Available : I/O mapping
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : analog output module
    • Protective Treatment : conformal coating
    • Range Of Product : Modicon X80
    • Returnability : No
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Temperature Drift : 45 ppm/°C
    • Topology : point-to-point
    • Total Lifecycle Carbon Footprint : 263 kg CO2 eq.
    • Pep Code : ENVPEP2311046EN
    • Database Version : 2022-01
    • Pep Verification Date : 2023-11-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : The Modicon M X80 range has a long life cycle for about more than 10 years with a 100% use rate. Typical electrical power is 1.79W (150 mA 3.3 V DC). The module offers the following ranges of voltage and current :& 10Voltage range: +/-5 V/+/-10 V/0..5 V/0..10 V/1..5 V,& 10Current range: +/-20 mA/0..20 mA/4..20 mA& 10& 10IP Degree of Protection: IP20& 10IEC 61010-2-201, IEC 61131-2,UL 61010-2-201,CSA C22.2 No 61010-2-201
    • Functional Unit Unit : Unit
    • Energy Model Manufacturing A1 A3 2 : Energy model used: Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Installation A5 2 : Electricity Mix; Production mix; Low voltage; US / Electricity Mix; Production mix; Low voltage; UE-27 / Electricity Mix; Production mix; Low voltage; APAC / Electricity Mix; Production mix; Low voltage; AUS
    • Energy Model Use B6 2 : Electricity Mix; Production mix; Low voltage; US / Electricity Mix; Production mix; Low voltage; UE-27 / Electricity Mix; Production mix; Low voltage; APAC / Electricity Mix; Production mix; Low voltage; AUS
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Production mix; Low voltage; US / Electricity Mix; Production mix; Low voltage; UE-27 / Electricity Mix; Production mix; Low voltage; APAC / Electricity Mix; Production mix; Low voltage; AUS
  • Environment Attributes Main
    • Directives : 2014/35/EU - low voltage directive, 2014/30/EU - electromagnetic compatibility, 2014/34/EU - ATEX directive
    • Operating Altitude : 0...6561.68 ft (0...2000 m), 2000...5000 m with derating factor
    • Product Compatibility : BMEP58... processor, BMEXBP... backplane, ABE7CPA21, head module BMECRA31210, BMXFTB20... terminal block
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 262.8381901327
    • Ambient Air Temperature For Operation : -25-60 °C
    • Ambient Air Temperature For Storage : -40-85 °C
    • Circularity Profile : ENVEOLI2311046EN
    • Environmental Disclosure : ENVPEP2311046EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2311046EN
    • Pep Verification Date : 2023-11-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : analog output module
    • Range Of Product : Modicon X80
  • ETIM
    • ETIM 8 : EC001420
    • ETIM 9 : EC001420
  • Output Attributes
    • Analogue Output Number : 4
    • Analogue Output Resolution : 15 bits + sign
    • Analogue Output Type : current 4...20 mA
  • Input Attributes
    • Input Output Isolation : isolated