SQUARE D

Voltage interface module, TeSys island, 690VAC 47-63 Hz, Isolated switching input for safe stop

TeSys Island�Voltage Interface

SQDTPRVM001 TPRVM001 3606489832889
260.96 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Depth: 114 mm
  • Warranty Length: 18 mth
TeSys island voltage interface module, 100-690V / 47-63Hz. Connected to a TPRBC bus coupler it measures the mains voltages powering the loads. It provides the voltage values for power and energy calculation, calculates the RMS values and phase sequence. Voltage measurement range 100-690 V +/- 5 %, phase frequency measurement range 47-63 Hz +/- 1 Hz in single phase or 3-phase systems. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Features
  • Specifications
TeSys island voltage interface module, 100-690V / 47-63Hz. Connected to a TPRBC bus coupler it measures the mains voltages powering the loads. It provides the voltage values for power and energy calculation, calculates the RMS values and phase sequence. Voltage measurement range 100-690 V +/- 5 %, phase frequency measurement range 47-63 Hz +/- 1 Hz in single phase or 3-phase systems. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Features
    • Monitoring of the mains voltage powering your loads
    • Reporting of the voltage to the bus coupler to enable power & energy monitoring
    • Manages motors and other electrical loads up to 65 A (AC-3) / 37 kW/40 hp
    • All adjustments and setting are digitized, no mechanical dials or dip switches
    • Embedded Cybersecurity (Achilles Level 2)
  • Prop 65
    • WARNING: This product can expose you to chemicals including: carbon black and Toluene, which are known to the State of California to cause cancer and/or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
  • Complementary Attributes
    • Ue Rated Operational Voltage : 690 V AC 47...63 Hz
    • Ui Rated Insulation Voltage : 690 V IEC 61010-1
    • Uimp Rated Impulse Withstand Voltage : 6 kV IEC 61010-1
    • Us Rated Supply Voltage : 24 V DC supplied by the bus coupler
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electromagnetic Compatibility : electrostatic discharge, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2, radiated RF fields, level 3, 10 V/m, conforming to EN/IEC 61000-4-3line voltage circuit: fast transients immunity test, level 3, 2 kV, conforming to EN/IEC 61000-4-4, line voltage circuit: surge immunity test (common mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5
    • Function Of Module : monitoring of voltages in single phase systems L-N or L-L, monitoring of voltages in 3-phase systems without neutral N connection, calculation of RMS phase voltages, voltage phase sequence, fundamental frequency, identification of dip and swell events level and duration
    • Local Signalling : 1 LED (green/red) for DS (device status), 1 LED (green/red) for VS (voltage status)
    • Metering Type : phase voltage 100...690 Vphase frequency 47...63 Hz, phase sequence
    • Connections Terminals : measuring input removable spring terminal block 3 0.2-2.5 mm² 24 AWG...14 AWG)rigidmeasuring input removable spring terminal block 3 0.2-2.5 mm² 24 AWG...14 AWG)flexible without cable end, measuring input removable spring terminal block 3 0.25-2.5 mm² 22 AWG...14 AWG)flexible with cable end
    • Certificate Agency : UL, CSA, EAC (pending)
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-06-27
    • Return Indicator : Y
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : No
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1904009EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1911
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Current Consumption : 2 mA
    • Device Short Name : TPRVM
    • Energy Efficiency Optimized : False
    • Fire Resistance : 960 °C UL 94
    • Measurement Accuracy : voltage +/- 5 %,frequency +/- 1 Hz,
    • Mounting Mode : horizontal and vertical 35 mm symmetrical rail)
    • Overvoltage Category : III
    • Power Dissipation In W : 0.5 W maximum
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys island
    • Product Or Component Type : voltage interface module
    • Protective Treatment : TC
    • Range : TeSys
    • Returnability : Yes
    • Shock Resistance : 15 gn 11 ms) IEC 60068-2-27
    • Sustainable Packaging : No
    • Vibration Resistance : 1.5 mm peak to peak 3-13 Hz) IEC 60068-2-61 gn 13-200 Hz) IEC 60068-2-6
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Height Nominal : 118 mm
    • Width Nominal : 25 mm
    • Nbr. Of Units In Pkg. : 1
    • Customs Code : 9030333800
    • Halogen Free Status : Halogen free plastic parts product
    • Warranty In Months : 18
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Ambient Air Temperature For Operation : -10-60 °C-10-60 °C
    • Ambient Air Temperature For Storage : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI1904009EN
    • Environmental Disclosure : ENVPEP1904009EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Ip Degree Of Protection : IP20
    • Operating Altitude : 0...6561.68 ft (0...2000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Product Compatibility : TPRBC bus coupler
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP1904009EN
  • General Attributes
    • Product Or Component Type : voltage interface module
  • ETIM
    • ETIM 8 : EC001596
    • ETIM 9 : EC001596
    • ETIM 10 : EC001596
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Indonesia
    • Depth : 114 mm
  • Overview Attributes
    • Device Presentation : monitoring of the mains voltage powering the island, reporting of the voltage to the bus coupler to enable power & energy monitoring